Sper scientific 800007 User manual

Category
Measuring, testing & control
Type
User manual

Sper scientific 800007 is a versatile and accurate temperature measurement device with a wide range of capabilities. It can be used for various applications, including cooking, laboratory work, and industrial settings. Here are some of its key features and possible use cases:

  • Dual-probe input: The device can read and display results from two probes simultaneously, making it ideal for comparing temperatures in different locations or measuring the temperature difference between two objects.

  • Type K and J thermocouple compatibility: The device can be used with both Type K and Type J thermocouples, which are commonly used in various temperature measurement applications.

Sper scientific 800007 is a versatile and accurate temperature measurement device with a wide range of capabilities. It can be used for various applications, including cooking, laboratory work, and industrial settings. Here are some of its key features and possible use cases:

  • Dual-probe input: The device can read and display results from two probes simultaneously, making it ideal for comparing temperatures in different locations or measuring the temperature difference between two objects.

  • Type K and J thermocouple compatibility: The device can be used with both Type K and Type J thermocouples, which are commonly used in various temperature measurement applications.

Type K/J Thermometers
800004 & 800007
Instruction Manual
SPER
SCIENTIFIC
- 2 -
CONTENTS
1. INTRODUCTION ................................ 2
2. PANEL DESCRIPTION ...................... 3
3. OPERATING INSTRUCTIONS .......... 4
3-A. Measuring Procedures ............... 4
3-B. Hold ............................................ 4
3-C. Max/Min ..................................... 5
3-D. Relative Measurement ............... 5-6
3-F. T1-T2 Difference, 800007 only ... 6
4. AUTO POWER OFF ........................... 6
5. BATTERY REPLACEMENT ............... 7
6. SPECIFICATIONS ............................. 7
7. OPTIONAL ACCESSORIES .............. 8
8. WARRANTY ....................................... 8
1. INTRODUCTION
Mini sized and light weight, this unit provides
extremely accurate and reliable temperature
measurement with all the versatility and range of
type K & J thermometers. Features relative,
min/max temperature, hold, auto power off, and
touch tone buttons. Model 800007 will read and
display results from two probes simultaneously
and track the difference between them (T1-T2).
Comes with a 9V battery and beaded wire probe
(2 probes for 800007). CE rated.
- 3 -
2. PANEL DESCRIPTION
1 Probe Input
(top of unit)
2 Display
3 °C/°F
4 MAX/MIN
5 K/J
6 REL (relative)
7 HOLD
8 Power
9 T1-T2
(difference,
800007 only)
10 Battery
Compartment
(back of unit)
!
24V
- + MAX - +
- 4 -
3. OPERATING INSTRUCTIONS
Refer to page 3 for button locations.
3-A. Measuring Procedures
Press the POWER (8) button.
Press the °C/°F (3) button to select the tem-
perature scale. "°C" or "°F" is displayed.
Press the K/J (5) button to select your sensor
type. "K" or "J" is displayed.
Insert the probe plug(s) into the PROBE IN-
PUT (1) socket. Be sure to match the plug's
polarity to the input's polarity ( - + ).
The temperature reading(s) will be displayed.
For 800007, the T1 reading appears on the
upper half of the display and the T2 reading
appears on the lower half of the display.
NOTE: To obtain the most accurate reading,
the probe plug must be the same temperature
as the socket.
3-B. Hold Function
Press the HOLD (7) button during measure-
ment to freeze the displayed temperature.
"HOLD" and the temperature are shown
Press the HOLD (7) button again to exit this
function.
- 5 -
3-C. MAX/MIN FUNCTION
The max/min temperatures are held in memory
until the meter is turned off. The thermometer
must be in the max/min function to record max
(peak) or min values.
With the meter on, press the MAX/MIN (4)
button once. "MAX" and the maximum re-
corded peak temperature are displayed.
The displayed max value is updated only
when exceeded.
Press the MAX/MIN (4) button again. "MIN"
and the minimum temperature are displayed
The displayed min value is updated when
there is a lower temperature reading.
To exit this function, press and hold the
MAX/MIN (4) button for at least 2 seconds.
The current temperature is displayed.
NOTE: The POWER, C/F, K/J, REL and T1-T2
buttons will not operate in Max/Min mode.
3-D. Relative Measurement
Press the REL (6) button during measure-
ment to store the current temperature into
memory. "REL" and "0.0°" are displayed.
As subsequent temperatures are measured,
the difference (higher/lower) is displayed.
- 6 -
Press the REL (6) button again to exit.
EXAMPLE: A temperature reading of 75.0°F
was stored in memory by pressing the REL but-
ton. Next, the probe was placed in an environ-
ment where the temperature is 55.0°F. "REL"
and "-20.0°F" are displayed.
3-F. T1-T2 Difference, 800007 only
This function uses two probes to
display the difference between
the T1 and T2 temperatures.
With the meter on, press the
T1-T2 (9) button once.
In this example, the T1 value is
79.5°F, the T2 value is 52.3°F,
and the difference is 27.2°F. Or,
T1 (79.5) - T2 (52.3) = 27.2°F.
NOTE: The MAX/MIN (4) and REL (6) buttons
will not operate in Difference mode.
4. AUTO POWER OFF
If no buttons are pushed for about 20 minutes,
the meter will automatically turn off.
T1 °F
K 79.5
K 52.3°F
T2
T1-T2
°F
K 27.2
K 52.3°F
T2
- 7 -
Accuracy ±0.3% rdg + 1°C, 2°F
-200 ~ 200°C&F & >400°C&F
otherwise ±0.5% rdg + 1°C, 2°F
Type K -328 ~ 2498°F (-200 ~ 1370°C )
Type J -328 ~ 1922°F (-200 ~ 1050°C )
Res. 0.1
Weight 6 oz (170g)
Dim. 5¼ x 2 ¼ x 1¼" (130 x 56 x 38mm)
Operating
& Storage
Environ.
32°F ~ 122°F (0°C ~ 50°C)
RH <80%
Overload
Indicator
OL for over range (positive temp.),
or without thermocouple. -OL for
below range (negative temp.)
5. BATTERY REPLACEMENT
When the low battery icon is displayed, turn off
the meter and remove the probes.
Slide BATTERY COMPARTMENT (10) cover
down to install a fresh 9V battery.
Replace the cover. Battery life is apx. 200 hrs.
6. SPECIFICATIONS
- 8 -
REV 8/21/06
7. OPTIONAL ACCESSORIES
800060~97 Type K / J Thermocouple Probes
840090 Water Resistant Instrument Pouch
8. WARRANTY
Sper Scientific warrants this product against
defects in materials and workmanship for five
(5) years from the date of purchase, and
agrees to repair or replace any defective unit
without charge. If your model has since been
discontinued, an equivalent Sper Scientific
product will be substituted if available. This
warranty does not cover damage resulting from
accident, misuse, or abuse of the product. To
obtain warranty service, ship the unit postage
prepaid to:
SPER SCIENTIFIC LTD
7720 E. Redfield Rd, Suite 7,
Scottsdale, AZ 85260
Email: info@sperscientific.com
The defective unit must be accompanied by a
description of the problem and your return
address. Register your product online at
www.sperscientific.com, or return your war-
ranty card within 10 days.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Sper scientific 800007 User manual

Category
Measuring, testing & control
Type
User manual

Sper scientific 800007 is a versatile and accurate temperature measurement device with a wide range of capabilities. It can be used for various applications, including cooking, laboratory work, and industrial settings. Here are some of its key features and possible use cases:

  • Dual-probe input: The device can read and display results from two probes simultaneously, making it ideal for comparing temperatures in different locations or measuring the temperature difference between two objects.

  • Type K and J thermocouple compatibility: The device can be used with both Type K and Type J thermocouples, which are commonly used in various temperature measurement applications.

Ask a question and I''ll find the answer in the document