H3C SecPath L5030 is a high-performance load balancing device that provides various features to enhance network performance and availability. It offers:

  • High scalability: With multiple expansion slots and support for up to 8 interface modules, the device can be easily scaled to meet growing network demands.
  • Comprehensive load balancing: Supports various load balancing algorithms, including Layer 4 and Layer 7, to distribute traffic efficiently and optimize server utilization.
  • Advanced traffic management: Features such as traffic shaping, QoS, and firewall provide granular control over network traffic, allowing for better prioritization and security.

H3C SecPath L5030 is a high-performance load balancing device that provides various features to enhance network performance and availability. It offers:

  • High scalability: With multiple expansion slots and support for up to 8 interface modules, the device can be easily scaled to meet growing network demands.
  • Comprehensive load balancing: Supports various load balancing algorithms, including Layer 4 and Layer 7, to distribute traffic efficiently and optimize server utilization.
  • Advanced traffic management: Features such as traffic shaping, QoS, and firewall provide granular control over network traffic, allowing for better prioritization and security.
Installation accessories 安装附件介绍
No installation tools are provided with the device. Prepare them yourself as required.
设备不随机提供安装工具,请用户根据实际安装需求自己准备安装工具。
1
Flat-blade screwdriver
一字螺丝刀
Phillips screwdriver
十字螺丝刀
Needle-nose pliers
尖嘴钳
ESD wrist strap
防静电腕带
Diagonal pliers
斜口钳
BOM: 3104A0WC
Tool list 工具参考
H3C SecPath L5030[L5060][L5080][L5000-E] Load Balancing Device Installation Quick Start-APW101
H3C SecPath L5030[L5060][L5080][L5000-E]负载均衡设备 快速安装指南-APW101
Wear an ESD wrist strap, and make sure the wrist strap makes good skin contact and is reliably grounded.
操作者需佩戴防静电腕带,确保防静电腕带与皮肤良好接触,并确认防静电腕带已经良好接地。
Cage nut
浮动螺母
M4 screw
M4挂耳螺钉
M6 screw
M6机柜螺钉
W
ir
e
-
s
t
r
ip
p
in
g
p
li
e
r
s
线
W
ir
e
c
r
im
p
e
r
线
Mounting brackets with cable
management brackets
带走线架的挂耳
2
Installing a fan tray 安装风扇模块
The FAN-20F-2-A blows air from the power module side to the port side and the fan tray handle is blue. The
FAN-20B-2-A draws air from the port side to the power module side and the fan tray handle is red.
Before installing a fan tray, make sure the fan tray has an airflow direction that draws in cool air from the
cold aisle and exhausts hot air to the hot aisle.
You must install fan trays of the same model on a device.
FAN-20F-2-A为吹风风扇,风向为电源侧进风,端口侧出风,风扇把手为蓝色;FAN-20B-2-A为抽风风扇,
风向为端口侧进风,电源侧出风,风扇把手为红色
安装风扇模块前,请根据风扇模块的风向指示,确认气流方向和安装环境的通风要求一致。
不支持抽风风扇和吹风风扇混插。
Marker
记号笔
The device comes with the two fan tray slots empty. Before powering on the device, make sure the device
has two fan trays of the same model installed.
If one or both fan trays fail during the device operation, replace the fan trays immediately and keep the fan
trays in position before the replacement.
设备出厂时两个风扇插槽均为空为保证设备的正常散热用户必须安装两个相同型号的风扇模块否则
禁止设备上电运行
在设备运行过程中,如果一个或两个风扇模块出现故障,请及时进行更换,且更换故障风扇模块前需保持
故障风扇模块在位。
Grounding cable
地线
Removable cable tie
扎带
Slide rails and chassis rails
滑道及滑道导轨
Correctly orient the fan tray with
the "TOP" mark on top.
请确保“TOP”标识朝上
Airflow direction of the device 设备风向设计
The device can provide front-to-rear or rear-to-front airflow by using different fan trays.
设备采用前后风道设计,通过安装不同的风扇模块,提供两种散热方式,满足不同环境下的散热要求。
1
2
1
FAN-20F-2-A fan tray
FAN-20F-2-A风扇模块
FAN-20B-2-A fan tray
FAN-20B-2-A风扇模块
The installation procedure is similar for the L5030, L5060, L5080, and L5000-E devices. This guide uses the
L5000-E as an example.
L5030/L5060/L5080/L5000-E安装方法类似,本手册仅以L5000-E为例进行介绍。
3
4
Attaching the cage nuts and slide rails to the rack 安装浮动螺母及滑道
Mounting the device in a rack 安装设备
Attaching the mounting brackets and chassis rails to the
device 安装挂耳及导轨到设备
Connecting the grounding cable 连接保护地线
The device has a primary grounding point (above the power module slots) and an auxiliary grounding point.
The primary grounding point has a grounding sign and grounding screw while the auxiliary grounding point does
not. The grounding screw for the primary grounding point is also applicable to the auxiliary grounding point.
To use the auxiliary grounding point, connect the grounding cable to it before mounting the device in a rack.
主接地点(电源模块上方接地点)标有接地标识,并带有接地螺钉,备用接地点无接地标识和接地螺钉。
主接地点上的接地螺钉同样适用于备用接地点
为了防止机箱安装到机柜后无法安装备用接地线,请您先连接备用接地点。
The device provides multiple chassis rail installation positions on its sides. Determine the chassis rail
installation position based on the rack depth and make sure the front ends of slide rails reach out the
chassis rails for the device stability.
The following figure uses installing the mounting brackets near the hard disk side as an example.
设备侧面板提供了多个滑道导轨安装位,用户可根据机柜的深度,调整滑道导轨的安装位置;为保证设备
安装后的稳定性,当滑道与滑道导轨安装完成后,请确保滑道的头部露出滑道导轨。
的安装位置 ,请根据实际安装场景的
安装位置。
Rack requirements 推荐机柜尺寸
Auxiliary grounding point
备用接地点
Chassis dimensions设备尺寸 Rack requirements对机柜的要求
Height—88.1 mm (3.47 in)
Width—440 mm (17.32 in)
Depth—775.5 mm (30.53 in)
660 mm (25.98 in) for the chassis
90 mm (3.54 in) for the cable management brackets at the front
25.5 mm (1.00 in) for the power module handle at the rear
宽度 440 mm
高度 88.1 mm
装配完成后总深度 775.5 mm
机箱本体深度 660 mm
前侧信号线走线架深度 90 mm
后侧电源模块拉手深度 25.5 mm
A minimum of 1000 mm (39.37 in) in depth
(recommended)
A minimum of 100 mm (3.94 in) between the front
rack posts and the front door
A minimum of 760 mm (29.92 in) between the front
rack posts and the rear door
518 mm (20.39 in) to 858 mm (33.78 in) between
the front and rear rack posts
H3C推荐您选配1000mm及以上深的机柜,并且要求:
前方孔条到前门有不小于 100 mm空间
前方孔条到后门有不小于 760 mm空间
前后方孔条间距518mm858mm
Primary grounding point
主接地点
Installing and removing a hard disk 安装与拆卸硬盘
Installing a hard disk 安装硬盘
Hard disks are not hot swappable.
No hard disk is provided with the device. Prepare them yourself as required. For the system to identify the
disks, use disks from H3C.
To avoid ESD damage, always wear an ESD wrist strap when working with a hard disk.
Hold a hard disk by its two sides and do not touch its components or squeeze, shake, or hit the hard disk.
Install a filler module in an unused hard disk slot to prevent dust from entering the chassis.
For a hard disk to operate correctly, execute the fdisk and format commands to partition and format the
file system before using the hard disk.
Before removing a partitioned hard disk, you must use the umount command to unmount all file systems
on the hard disk.
硬盘不支持热插拔。
设备不随机提供硬盘,请您根据需求自行选购。
请采用H3C公司的硬盘,否则系统无法识别。
安装和拆卸硬盘时,请佩戴防静电腕带以避免硬盘受到静电放电的损害。
手接触硬盘时拿硬盘的两侧,不要触碰元器件或挤压、振动、撞击硬盘。
若不再安装硬盘时,请安装假面板,以避免灰尘或异物进入设备内部造成静电吸附或损坏。
为确保硬盘的正常使用,使用硬盘前,需在命令行视图下执行fdiskformat命令,对硬盘进行分区及格式
化操作。
在拔出硬盘前,需在命令行视图下执行umount命令,卸载所有的分区才能安全拔出硬盘,否则,可能会引
起硬盘存储介质的损坏。
Installing interface modules安装接口模块
Mounting the device in a rack 安装设备到机柜
U
s
e
M
6
s
c
r
e
w
s
t
o
s
e
c
u
r
e
t
h
e
d
e
v
ic
e
in
t
h
e
r
a
c
k
.
使
M
6
Interface modules are not hot swappable.
To avoid module damage, do not touch the components on an interface module.
Install a filler panel in an unused slot to prevent dust from entering the chassis and ensure good ventilation.
接口模块不支持热插拔。
请勿直接接触接口模块上的元器件,避免造成损坏。
若设备插槽没有安装接口模块,请及时安装假面板,防止灰尘进入设备,同时又保证设备的良好通风散热。
Compatible slots for the interface modules 接口模块安装槽
5
Interface module 接口模块
Compatible slots 安装槽位
NSQM1TG8A
NSQM1QG2A
NSQM1G4XS4
NSQM1GT8A
NSQM1GP8A
NSQM1GT4PFCA
Slots 1 to 3
Slots 4 to 8
Install the interface modules into the compatible slots. 不同接口模块适配的槽位不同
6
3
2
1
Remove the filler module from the hard disk slot and then push the hard disk slowly into the slot along the slide rails.
先拆下硬盘卡槽假面板,然后将硬盘沿着插槽导轨缓慢的推进插槽。
1
1
2
3
4
4
5
5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

H3C SecPath L5030 Installation, Quick Start

Type
Installation, Quick Start

H3C SecPath L5030 is a high-performance load balancing device that provides various features to enhance network performance and availability. It offers:

  • High scalability: With multiple expansion slots and support for up to 8 interface modules, the device can be easily scaled to meet growing network demands.
  • Comprehensive load balancing: Supports various load balancing algorithms, including Layer 4 and Layer 7, to distribute traffic efficiently and optimize server utilization.
  • Advanced traffic management: Features such as traffic shaping, QoS, and firewall provide granular control over network traffic, allowing for better prioritization and security.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages