Sanyo KMHS0772 Technical & Service Manual

Category
Split-system air conditioners
Type
Technical & Service Manual

This manual is also suitable for

CMH1972 (3-room multi unit)
CMH2472 (4-room multi unit)
CMH3172 (4-room multi unit)
< Applicable Multi-Outdoor Units >
TECHNICAL & SERVICE MANUAL
INDOOR UNIT : KMHS0772
KMHS0972
KMHS1272
KMHS1872
KMHS2472
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
FILE NO.
Destination: North America
Wall Mounted Type Indoor Unit
KMHS0772
KMHS0972
KMHS1272
KMHS1872
KMHS2472
REFERENCE NO. SM700659-02
Product Code No.
1 852 099 92
1 852 099 93
1 852 099 94
1 852 099 95
1 852 099 96
Capacity
7,500BTU / h
9,000BTU / h
11,900BTU / h
17,500BTU / h
24,200BTU / h
Indoor Model No.
KMHS0772
KMHS0972
KMHS1272
KMHS1872
KMHS2472
NOTE
AIR
C
O
N
DITIONER
A
IR
C
O
N
DITIONER
IMPORTANT
These air conditioners employ new
refrigerant R410A.
Pay special attention when
servicing the unit.
For details about the combinations, refer to
“Unit Combination Table” in the
T. Service
Manual
for the Multi Outdoor Units.
When Wiring
ELECTRICAL SHOCK CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH.
ONLY A QUALIFIED, EXPERIENCED
ELECTRICIAN SHOULD ATTEMPT TO
WIRE THIS SYSTEM.
SPECIAL PRECAUTIONS
This symbol refers to a hazard
or unsafe practice which can
result in severe personal
injury or death.
This symbol refers to a hazard
or unsafe practice which can
result in personal injury or
product or property damage.
CAUTION
CAUTION
WARNING
WARNING
Important!
Please Read Before Starting
This air conditioning system meets strict safety and operating
standards. As the installer or service person, it is an
important part of your job to install or service the system so it
operates safely and efficiently.
For safe installation and trouble-free operation, you must:
Carefully read this instruction booklet before beginning.
Follow each installation or repair step exactly as shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices given
in this manual.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help for
a special problem, contact our sales/service outlet or
your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.
Do not supply power to the unit until all wiring and tubing
are completed or reconnected and checked.
Highly dangerous electrical voltages are used in this
system. Carefully refer to the wiring diagram and these
instructions when wiring. Improper connections and
inadequate grounding can cause accidental injury or death.
Ground the unit following local electrical codes.
Connect all wiring tightly. Loose wiring may cause
overheating at connection points and a possible fire
hazard.
When Transporting
Be careful when picking up and moving the indoor and
outdoor units. Get a partner to help, and bend your knees
when lifting to reduce strain on your back. Sharp edges or thin
aluminum fins on the air conditioner can cut your fingers.
When Installing
In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the unit’s
weight. It may be necessary to construct a strong wood or
metal frame to provide added support.
In a Room
Properly insulate any tubing run inside a room to prevent
"sweating" that can cause dripping and water damage to walls
and floors.
In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a
solid, level foundation for the outdoor unit. This prevents water
damage and abnormal vibration.
In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is higher than
drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
Use the flare method for connecting tubing.
Apply refrigerant lubricant to the matching surfaces of the
flare and union tubes before connecting them, then tighten
the nut with a torque wrench for a leak-free connection.
Check carefully for leaks before starting the test run.
When Servicing
Tu rn the power off at the main power box (mains) before
opening the unit to check or repair electrical parts and
wiring.
Keep your fingers and clothing away from any moving parts.
Clean up the site after you finish, remembering to check
that no metal scraps or bits of wiring have been left inside
the unit being serviced.
Others
Ventilate any enclosed areas when installing or testing the
refrigeration system. Escaped refrigerant gas, on contact
with fire or heat, can produce dangerously toxic gas.
Confirm upon completing installation that no refrigerant gas
is leaking. If escaped gas comes in contact with a stove,
gas water heater, electric room heater or other heat source,
it can produce dangerously toxic gas.
2
Table of Contents
APPLICABLE MULTI-OUTDOOR UNITS
1. OPERATING RANGE
2. SPECIFICATIONS
2-1. Unit Specifications
2-2. Major Component Specifications
2-3. Other Component Specifications
3. DIMENSIONAL DATA
4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
5. PERFORMANCE DATA
5-1. Air Throw Distance Charts
6. ELECTRICAL DATA
6-1. Electric Wiring Diagrams
7. FUNCTIONS
7-1. Operation Functions
7-2. Protective Functions
8. TROUBLESHOOTING
8-1. Precautions before Performing Inspection or Repair
8-2. Method of Self-Diagnostics
8-3. Checking the Indoor and Outdoor Units
8-4. Trouble Diagnosis of Fan Motor
8-5. Noise Malfunction and Electromagnetic Interference
APPENDIX A INSTRUCTION MANUAL
APPENDIX B INSTALLATION INSTRUCTIONS
4
5
6
16
21
22
24
25
30
32
34
35
35
38
41
42
A-1
A-2
...................................................................................
...................................................................................................................
.............................................................................................................
.......................................................................................
.......................................................................................
....................................................................................................................
..................................................................................................
.......................................................................................................
....................................................................................................
...........................................................................................................
...........................................................................................................
..........................................................
.................................................................................................
..............................................................................
..........................................................................................
..........................................................
.........................................................................................
............................................................................
Page
3
APPLICABLE MULTI-OUTDOOR UNITS
KMHS0772
KMHS0972
KMHS1272
KMHS1872
KMHS2472
3-Room
CMH1972
YES
YES
YES
YES
NO
4-Room
CMH2472
YES
YES
YES
YES
YES
4-Room
CMH3172
YES
YES
YES
YES
YES
Indoor Unit
Multi-Outdoor Unit
4
95 °F D.B. / 71 °F W.B.
67 °F D.B. / 57 °F W.B.
80 °F D.B. / 67 °F W.B.
_
D.B. /
_
W.B.
1. OPERATING RANGE
Maximum
Minimum
Maximum
Minimum
115 °F D.B.
67 °F D.B.
75 °F D.B. / 65 °F W.B.
0 °F D.B.
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Heating
5
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit KMHS0772
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.11
25
0.11
25
7,500
2.20
8,500
2.50
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
230V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
33 / 30 / 27 / 2333 / 30 / 27 / 23
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer, 1-Hour OFF Timer
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 230V >
Type
241 (410) 271 (460)Air Circulation (High) ft
3
/min (m
3
/h)
2.77 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
6
Indoor Unit KMHS0772
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.12
25
0.12
25
7,500
2.20
8,500
2.50
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
208V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
33 / 30 / 27 / 2333 / 30 / 27 / 23
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 208V >
Type
241 (410) 271 (460)Air Circulation (High) ft
3
/min (m
3
/h)
2.77 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
7
Indoor Unit KMHS0972
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.15
35
0.15
35
9,000
2.65
12,200
3.60
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
230V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
34 / 31 / 28 / 2334 / 31 / 28 / 23
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 230V >
Type
259 (440) 282 (480)Air Circulation (High) ft
3
/min (m
3
/h)
3.4 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
8
Indoor Unit KMHS0972
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.17
35
0.17
35
9,000
2.65
12,200
3.60
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
208V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
34 / 31 / 28 / 2334 / 31 / 28 / 23
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 208V >
Type
259 (440) 282 (480)Air Circulation (High) ft
3
/min (m
3
/h)
3.4 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
9
Indoor Unit KMHS1272
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.15
35
0.15
35
11,900
3.50
14,300
4.20
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
230V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
34 / 31 / 29 / 2536 / 33 / 29 / 25
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 230V >
Type
282 (480) 294 (500)Air Circulation (High) ft
3
/min (m
3
/h)
4.26 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
10
Indoor Unit KMHS1272
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.17
35
0.17
35
11,900
3.50
14,300
4.20
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
208V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
19.8
24.3
2.82
(9.0)
(11.0)
10-1/32 (255)
35-7/16 (900)
13-25/32 (350)
7-7/16 (189)
32-15/32 (825)
11-7/32 (285)
(0.08)
1/4 (6.35)
3/8 (9.52)
Flare Type
34 / 31 / 29 / 2536 / 33 / 29 / 25
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 208V >
Type
282 (480) 294 (500)Air Circulation (High) ft
3
/min (m
3
/h)
4.26 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
11
Indoor Unit KMHS1872
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.15
35
0.15
35
17,500
5.15
20,400
6.00
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
230V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
26.5
33.1
4.23
(12.0)
(15.0)
14-29/32 (379)
44-7/8 (1,140)
11-3/8 (289)
8-19/32 (218)
41-15/16 (1,065)
11-23/32 (298)
(0.12)
1/4 (6.35)
1/2 (12.7)
Flare Type
40 / 37 / 34 / 2841 / 38 / 34 / 28
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 230V >
Type
500 (850) 500 (850)Air Circulation (High) ft
3
/min (m
3
/h)
4.89 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
12
Indoor Unit KMHS1872
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.17
35
0.17
35
17,500
5.15
20,400
6.00
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
208V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
26.5
33.1
4.23
(12.0)
(15.0)
14-29/32 (379)
44-7/8 (1,140)
11-3/8 (289)
8-19/32 (218)
41-15/16 (1,065)
11-23/32 (298)
(0.12)
1/4 (6.35)
1/2 (12.7)
Flare Type
40 / 37 / 34 / 2841 / 38 / 34 / 28
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 208V >
Type
500 (850) 500 (850)Air Circulation (High) ft
3
/min (m
3
/h)
4.89 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
13
Indoor Unit KMHS2472
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.20
45
0.20
45
24,200
7.10
29,000
8.50
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
230V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
26.5
33.1
4.23
(12.0)
(15.0)
14-29/32 (379)
44-7/8 (1,140)
11-3/8 (289)
8-19/32 (218)
41-15/16 (1,065)
11-23/32 (298)
(0.12)
1/4 (6.35)
5/8 (15.88)
Flare Type
43 / 40 / 37 / 3044 / 41 / 38 / 30
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 230V >
Type
541 (920) 541 (920)Air Circulation (High) ft
3
/min (m
3
/h)
4.89 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
14
Indoor Unit KMHS2472
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Vertical
dB-AIndoor : Hi/Me/Lo/Qt*
Air Filter
Refrigerant
0.22
45
0.22
45
24,200
7.10
29,000
8.50
Shipping Volume
Cooling Heating
Cooling Heating
Net
Shipping
Package Dimensions
Weight
Width
Depth
Height
Height
Ib. (kg)
Ib. (kg)
cu.ft (m
3
)
inch (mm)
inch (mm)
inch (mm)
208V Single-Phase 60Hz
inch (mm)
inch (mm)
187 to 253
Dimensions & Weight
(*Qt = Quiet mode)
Refrigerant Tubing Connections
Unit Dimensions
Operation Sound
Electrical Rating
WPower Input
V
A
Available Voltage Range
Running Amperes
Refrigerant Tubing Kit / Accessories
Narrow tube
Wide tube
Refrigerant inch (mm)
Tube Diameter inch (mm)
26.5
33.1
4.23
(12.0)
(15.0)
14-29/32 (379)
44-7/8 (1,140)
11-3/8 (289)
8-19/32 (218)
41-15/16 (1,065)
11-23/32 (298)
(0.12)
1/4 (6.35)
5/8 (15.88)
Flare Type
43 / 40 / 37 / 3044 / 41 / 38 / 30
R410A
Washable, Anti-Mold
Manual
Auto
Timer
Indoor Fan Speeds
24-Hour ON or OFF Timer Control
Auto and 3 steps
Airflow Direction (Indoor) Horizontal
Control / Temperature Control
Control Unit
Microprocessor / I.C. Thermister
Wireless Remote Control Unit
Features
Optional / Air Clean Filter
BTU/h
Performance
Voltage Rating
kW
Capacity
Wall Mounted Type Indoor Unit
< 208V >
Type
541 (920) 541 (920)Air Circulation (High) ft
3
/min (m
3
/h)
4.89 -Moisture Removal (High) Pints/h
Width
Depth
inch (mm)
15
Indoor Unit KMHS0772
MP24Z3
Flap Motor
Type Stepping Motor
Rating
Model
Coil Resistance Ohm
(Ambient Temp. 77 °F (25 °C))
Each Pair of Terminal : 400 +/- 7%
DC 12V
Aluminum Plate Fin / Copper Tube
2
19.5
2.02 (0.188) Face Area
Coil
Rows
Fins per inch
Heat Exchanger Coil
ft
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Yes
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3A
CB-KMHS0772
1 ... D3-11/16 / L24-31/32 (D94/L634)
RCS-4MHVPIS4U
Cross-Flow
DC Motor
SIC-39CVL-D487-4 ... 1
8
-
47
1,050 / 1,100
Internal Controller
Yes
-
-
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
inch (mm)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over-Current Protection
Over-Heat Protection
(Ambient Temp. 68 °F (20 °C))
Run Capacitor Micro F
VAC
W
Ohm
2-2. Major Component Specifications
2-2-1. Indoor Unit
16
Indoor Unit KMHS0972
MP24Z3
Flap Motor
Type Stepping Motor
Rating
Model
Coil Resistance Ohm
(Ambient Temp. 77 °F (25 °C))
Each Pair of Terminal : 400 +/- 7%
DC 12V
Aluminum Plate Fin / Copper Tube
2
19.5
2.02 (0.188) Face Area
Coil
Rows
Fins per inch
Heat Exchanger Coil
ft
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Yes
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3A
CB-KMHS0972
1 ... D3-11/16 / L24-31/32 (D94/L634)
RCS-4MHVPIS4U
Cross-Flow
DC Motor
SIC-39CVL-D847-4 ... 1
8
-
47
1,100 / 1,150
Internal Controller
Yes
-
-
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
inch (mm)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over-Current Protection
Over-Heat Protection
(Ambient Temp. 68 °F (20 °C))
Run Capacitor Micro F
VAC
W
Ohm
17
Indoor Unit KMHS1272
MP24Z3
Flap Motor
Type Stepping Motor
Rating
Model
Coil Resistance Ohm
(Ambient Temp. 77 °F (25 °C))
Each Pair of Terminal : 400 +/- 7%
DC 12V
Aluminum Plate Fin / Copper Tube
2
19.5
2.02 (0.188) Face Area
Coil
Rows
Fins per inch
Heat Exchanger Coil
ft
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Yes
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3A
CB-KMHS1272
1 ... D3-11/16 / L24-31/32 (D94/L634)
RCS-4MHVPIS4U
Cross-Flow
DC Motor
SIC-39CVL-D847-4 ... 1
8
-
47
1,200 / 1,200
Internal Controller
Yes
-
-
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
inch (mm)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over-Current Protection
Over-Heat Protection
(Ambient Temp. 68 °F (20 °C))
Run Capacitor Micro F
VAC
W
Ohm
18
Indoor Unit KMHS1872
MP24Z3
Flap Motor
Type Stepping Motor
Rating
Model
Coil Resistance Ohm
(Ambient Temp. 77 °F (25 °C))
Each Pair of Terminal : 400 +/- 7%
DC 12V
Aluminum Plate Fin / Copper Tube
2
19.5
3.07 (0.285) Face Area
Coil
Rows
Fins per inch
Heat Exchanger Coil
ft
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Yes
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3A
CB-KMHS1872
1 ... D3-11/16 / L33-9/32 (D94/L845)
RCS-4MHVPIS4U
Cross-Flow
DC Motor
SIC-39CVL-D847-2 ... 1
8
-
30
1,200 / 1,200
Internal Controller
Yes
-
-
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
inch (mm)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over-Current Protection
Over-Heat Protection
(Ambient Temp. 68 °F (20 °C))
Run Capacitor Micro F
VAC
W
Ohm
19
Indoor Unit KMHS2472
MP24Z3
Flap Motor
Type Stepping Motor
Rating
Model
Coil Resistance Ohm
(Ambient Temp. 77 °F (25 °C))
Each Pair of Terminal : 400 +/- 7%
DC 12V
Aluminum Plate Fin / Copper Tube
2
19.5
3.07 (0.285) Face Area
Coil
Rows
Fins per inch
Heat Exchanger Coil
ft
2
(m
2
)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Yes
Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 3A
CB-KMHS2472
1 ... D3-11/16 / L33-9/32 (D94/L845)
RCS-4MHVPIS4U
Cross-Flow
DC Motor
SIC-39CVL-D847-2 ... 1
8
-
30
1,300 / 1,300
Internal Controller
Yes
-
-
Fan
Remote Control Unit
Q'ty ... Dia. and Length
Type
inch (mm)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over-Current Protection
Over-Heat Protection
(Ambient Temp. 68 °F (20 °C))
Run Capacitor Micro F
VAC
W
Ohm
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88

Sanyo KMHS0772 Technical & Service Manual

Category
Split-system air conditioners
Type
Technical & Service Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI