Sony BKSI-2441, BKSI-2040 Series, BKSI-2042, BKSI-2043, BKSI-2044, BKSI-2440 Series Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Sony BKSI-2441 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
iDC CPU BOARD
BKSI-2440
iDC LINK INTERFACE BOARD
BKSI-2441
IDC SERIAL I/F CONNECTOR BOARD
BKSI-2042
IDC PARALLEL I/F CONNECTOR BOARD
BKSI-2043
IDC S-BUS I/F CONNECTOR BOARD
BKSI-2044
INSTALLATION MANUAL
2nd Edition (Revised 1)
Serial No. 10112 and Higher: BKSI-2440
Serial No. 10026 and Higher: BKSI-2441
Serial No. 10490 and Higher: BKSI-2042
Serial No. 10589 and Higher: BKSI-2043
Serial No. 10730 and Higher: BKSI-2044
BKSI-2440
! WARNING
This manual is intended for qualified service personnel only.
To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so. Refer all servicing to
qualified service personnel.
! WARNUNG
Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt.
Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die
Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei
Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben
Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung
dazu besitzen.
! AVERTISSEMENT
Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin
de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les
réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres.
Pour toute réparation faire appel à une personne compétente uniquement.
BKSI-2440
PRECAUTION
Do not install with turning the power on
Touching the power contact portion or the primary
winding circuit may cause electric shock. Turn off the
power and unplug the appliance from the outlet before
installing.
When disconnecting a connector, be careful about
the edges on the connector panel
Disconnecting a connector with excessive force may
cause an injury of your fingers from the edges on the
connector panel.
Hold a harness of a connector firmly, and disconnect it
softly.
1 (P)
BKSI-2440
1 (E)
Table of Contents
Manual Structure
Purpose of this manual ........................................................................................ 3 (E)
Related manual .................................................................................................... 3 (E)
Contents ............................................................................................................... 4 (E)
Trademarks .......................................................................................................... 4 (E)
1. Installation
1-1. Overview ............................................................................................... 1-1 (E)
1-2. Installation of the Board ........................................................................1-3 (E)
1-2-1. Plug-in Board Installation .................................................... 1-3 (E)
1-2-2. Connector Panel Installation ................................................ 1-4 (E)
1-3. Connection ............................................................................................ 1-6 (E)
1-3-1. Connection between SMS Gateway and SIU-80A/80 ......... 1-6 (E)
1-3-2. Connection of iDC Link ....................................................... 1-6 (E)
1-4. Information of BKSI-2440 .................................................................... 1-8 (E)
1-4-1. Setting and Function of Switches/LEDs on Board .............. 1-8 (E)
1-5. Information of BKSI-2441 .................................................................. 1-10 (E)
1-5-1. Location and Function of Connectors ................................1-10 (E)
1-5-2. Connecting Connector and Cables .....................................1-10 (E)
1-5-3. Signal Inputs/Outputs ......................................................... 1-11 (E)
1-5-4. Switch Setting ....................................................................1-11 (E)
1-6. Information of BKSI-2042 .................................................................. 1-12 (E)
1-6-1. Location and Function of Connectors ................................1-12 (E)
1-6-2. Connecting Connector ........................................................1-12 (E)
1-6-3. Signal Inputs/Outputs ......................................................... 1-13 (E)
1-6-4. Switch Setting ....................................................................1-13 (E)
1-6-5. Connection of the RS-232C/422A Connectors ..................1-14 (E)
1-7. Information of BKSI-2043 .................................................................. 1-15 (E)
1-7-1. Location and Function of Connectors ................................1-15 (E)
1-7-2. Connecting Connector ........................................................1-15 (E)
1-7-3. Signal Inputs/Outputs ......................................................... 1-15 (E)
1-8. Information of BKSI-2044 .................................................................. 1-16 (E)
1-8-1. Location and Function of Connectors ................................1-16 (E)
1-8-2. Connecting Connector and Cable ....................................... 1-16 (E)
1-8-3. S-BUS/VS-BUS Connection Examples ............................. 1-17 (E)
1-9. Specifications ...................................................................................... 1-18 (E)
3 (E)
BKSI-2440
Purpose of this manual
This manual is Installation Manual of the Intelligent Device Controller (iDC)
boards BKSI-2040 series and BKSI-2440 series.
This manual is intended for use by trained system and service engineers, and
describes the information when installing the following boards.
BKSI-2440 series
. BKSI-2440 iDC CPU Board
. BKSI-2441 iDC Link Interface Board
BKSI-2040 series
. BKSI-2042 IDC Serial I/F Connector Board
. BKSI-2043 IDC Parallel I/F Connector Board
. BKSI-2044 IDC S-BUS I/F Connector Board
Related manual
The following manual is prepared for this series.
..
..
. BKSI-2440 Maintenance Manual (Available on request)
This manual describes the general service information and detailed information
with the intention of servicing based on the component parts of BKSI-2440 series.
For obtaining, contact to your local Sony Sales Office/Service Center.
Part number: 9-968-014-0X
Manual Structure
4 (E)
BKSI-2440
Contents
This manual is organized by following sections.
1-1. Overview
This section describes the overview of BKSI-2440 series.
1-2. Installation of the Board
This section describes the installation of the boards to System Interface Unit SIU-
80A/80.
1-3. Connection
This section describes the connections between gateway and System Interface Unit
SIU-80A/80, and between two or more SIU-80A/80s.
1-4. Information of BKSI-2440
This section describes the information for BKSI-2440.
1-5. Information of BKSI-2441
This section describes the information for BKSI-2441.
1-6. Information of BKSI-2042
This section describes the information for BKSI-2042.
1-7. Information of BKSI-2043
This section describes the information for BKSI-2043.
1-8. Information of BKSI-2044
This section describes the information for BKSI-2044.
1-9. Specifications
This section describes the specifications of BKSI-2040 series and BKSI-2440 series.
Trademarks
Trademarks and registered trademarks used in this manual are follows.
. Ethernet is a registered trademark of Xerox Corporation.
. PC/AT is a registered trademark of International Business Machine, Inc.
1-1 (E)
BKSI-2440
1-1. Overview
Intelligent Device Controller (iDC) boards BKSI-2040 series (BKSI-2042/2043/2044) and BKSI-2440
series (BKSI-2440/2441) are installed in System Interface Unit SIU-80A/80, so as to control the devices
(Network Storage System, VTR, Routing Switcher, etc.) which are used in Server Management System
(SMS).
. The required power for operation of each board is supplied from System Interface Unit SIU-80A/80.
. The model label (1 set) is supplied with each board.
BKSI-2440 : iDC CPU BOARD (CPU-356 BOARD)
This is the main CPU board, and is used for the following two purposes.
1. For root controller
Transmits the application commands sent through the SMS gateway to the iDC boards
*
which are
controlled each device.
Multiple iDC boards controlling each device can be controlled by only one this board that is installed
in each Server Management System (SMS).
(The number of iDC boards which can be controlled by one this board depends on the installing
application software.)
*: Hereinafter, BKSI-2440/2441/2042/2043/2044 is described as iDC board.
2. For device controller
Each device of the SMS can be controlled when this board is used as a pair with each board BKSI-
2042, BKSI-2043 or BKSI-2044.
BKSI-2441 : iDC LINK INTERFACE BOARD (IF-905 BOARD)
This connector panel carrys out the interface with SMS gateway, or the interface between iDC boards.
BKSI-2042 : IDC SERIAL I/F CONNECTOR BOARD (IO-111 BOARD)
This connector panel is used for the RS-232C/422A interface.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
BKSI-2043 : IDC PARALLEL I/F CONNECTOR BOARD (IO-109 BOARD)
This connector panel is used for the interface of the input and output signals at
the parallel contacts.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
BKSI-2044 : IDC S-BUS I/F CONNECTOR BOARD (IO-110 BOARD)
This connector panel is used for the S-BUS/VS-BUS interface.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
n
To control the devices with the boards described above, the optional software (Server Management
Software BSS-1) is required.
Refer to the Installation manual supplied with the software for the installation procedures.
Section 1
Installation
1-2 (E)
BKSI-2440
Device controller CPU
BKSI-2440
BKSI-204x
Root controller CPU
BKSI-2440
BKSI-2441
Device controller CPU
BKSI-2440
BKSI-204x
Device controller CPU
BKSI-2440
BKSI-204x
LAN
Ethernet
SMS gateway
IBM PC/AT compatible machine with
BSS-1 software
SIU-80A/80
iDC
Controlled devices
PC with
Application software
iDC Concept
1-3 (E)
BKSI-2440
Procedures
1. Turn the SIU-80A/80 power off and remove the front
panel and shield plate.
(Refer to the Installation Manual supplied with SIU-
80A or SIU-80.)
2. Set the switches on the board. (Refer to “1-4-1. Setting
and Function of Switches/LEDs on Board”.)
3. Insert the board into a slot, and then turn the board
levers in the direction of the arrow 1 and connect the
board securely to the connector of the SIU-80A/80
units mother board.
4. Insert the Compact flash card into the Plug-in board.
5. Install the shield plate.
Then, attach the model label supplied with the board
on the right side of the shield plate.
This label position should be aligned with the slot
installing the board.
6. Install the front panel.
n
When removing the board, pull the board out from the
slot turning the board levers in the direction of the
arrow 2.
1-2. Installation of the Board
This section describes the installation procedures for the
front plug-in board and rear connector panel in a System
Interface Unit SIU-80A/80.
For more details of each procedure, refer to the applicable
sections and Installation Manual supplied with SIU-80A or
SIU-80.
1-2-1. Plug-in Board Installation
Flow for installation
Start
Slot selection
Switch setting on board
Plug-in board installation (BKSI-2440)
Compact flash card installation
Model label attachment
End
General information for installation
. The plug-in board (BKSI-2440) is inserted into any slot
No.1 to No.8 in the front of SIU-80A/80.
For the number of maximum boards to be installed in
SIU-80A/80, refer to the Installation Manual supplied
with SIU-80A or SIU-80.
. Install the Plug-in board (BKSI-2440) before inserting
the Compact flash card supplied with the BKS-2440 in
it.
. The model label supplied with the board is attached to
the shield plate to prevent the board inserting into the
incorrect slot when the board replacement and others.
1
2
1
2
1
2
Board lever Board lever
1 Install
2 Remove
SIU-80A/80
Plug-in board
Compact flash card
Front panel
PSW 3 x 6
Shield plate
SIU-80A/80
Model label
1-4 (E)
BKSI-2440
1-2-2. Connector Panel Installation
Flow for installation
Start
Slot selection
Switch setting on board
Model label attachment
Connector panel installation (BKSI-2441/2042/2043/2044)
End
General information for installation
. The connector panels (BKSI-2441/2042/2043/2044) are
inserted into any slot No.1 to No.8 in the rear of SIU-
80A/80.
. Each connector panel is inserted into the slot with the
same number as the BKSI-2440 installed in the front of
SIU-80A/80.
. The model label supplied with the connector panel is
attached to the chassis to prevent the panel inserting into
the incorrect slot when the connector panel replacement
and others.
w
Do not install with the power on
Touching the power contact portion or the primary
winding circuit on the SIU-80A/80 may cause electric
shock. Turn off the power and unplug the power cord from
the outlet before installing.
Information for inserting slot
A. When the board uses for root controller
Insert this board into the No.1 slot.
It is necessary to install the one root controller board in the
one Server Management System (SMS).
n
The root controller BKSI-2440 is able to control the
multiple iDC boards in the one Server Management
System by the only one.
For that reason, the root controller board has only to install
in the one out of multiple SIU-80A/80 units which are
installed in the iDC boards.
Theres no need to install the root controller board to the
other SIU-80A/80 units.
(Refer to 1-3-2. Connection of iDC Link.)
B. When the board uses for device controller
Insert this board into any slot No.2 to No.8.
1-5 (E)
BKSI-2440
5. When remove the connector panel, turn the power off
and remove the power cord plug from the receptacle,
and then remove the panel in the reverse order of steps
1 through 4.
n
To remove the connector panel, pull the right and left
handles on the connector panel until the connection
with the mother board is sufficiently loose, then pull
out the connector panel gently.
Information for inserting slot
BKSI-2441
Insert this connector panel into the No.1 slot.
Use this panel a pair with the root controller BKSI-2440
(plug-in board) which is inserted into the No.1 slot in the
front of SIU-80A/80.
n
When Server Management System has the multiple SIU-
80A/80 units installed the iDC boards, the root controller
BKSI-2440 is installed in the only one of SIU-80A/80
units.
BKSI-2042/2043/2044
These connector panels are inserted into any slot No.2 to
No.8 in the rear of SIU-80A/80.
Use each panel a pair with device controller BKSI-2440
which is inserted in the front slot of SIU-80A/80.
Blank panel
BVTT 3 x 6
SIU-80A/80
Connector panel
Model label
SIU-80A/80
BVTT
3 x 6
Procedures
1. Turn the SIU-80A/80 power off and unplug the power
cord from the outlet, and remove the blank panel at the
rear. (Refer to the Installation Manual supplied with
the SIU-80A or the SIU-80.)
2. Set the switches and connectors on the board (BKSI-
2042 only).
3. Attach the model label supplied with the connector
panel in the chassis near the slot to install the board.
n
After the connector panel is inserted into a slot, the
slot label cannot be seen.
4. Insert the connector panel to the matching slot and
secure the panel by the two screws which installed the
blank panel to the SIU-80A/80.
1-6 (E)
BKSI-2440
1-3. Connection
1-3-1. Connection between SMS Gateway
and SIU-80A/80
Connect the BKSI-2441 installed in the rear of SIU-80A/
80 with SMS gateway (IBM PC/AT compatible machine)
for the interface of commands with SMS gateway.
n
The Ethernet cables are used for the connection through
the Ethernet switching hub (100 Base-TX-capable).
Required equipments
. SMS gateway (IBM PC/AT compatible machine)
. Switching hub
. Ethernet cables
Connection of one SIU-80A/80 installed iDC
boards
1. Install the boards to the SIU-80A/80.
Front slot No.1 : Install the root controller BKSI-2440.
Rear slot No.1 : Install the BKSI-2441.
2. In the dip switch (ADDRESS) on the rear side of SIU-
80A/80, set #1 to Up.
3. Connect the Ethernet cables to the SMS gateway
throught the switching hub.
*1: Connected when a dual homing system (such as the FT server) is used
as the SMS gateway.
BKSI-2441
SMS gateway
SIU-80A/80 (Rear side)
Rear side
1
2
SMS GW
RJ-45
LAN connectors
RJ-45
Ethernet
switching hub
Ethernet cables
(Straight cable)
Ethernet cables
(Straight cable)
*1
12
ADDRESS
34
Connection of multiple SIU-80A/80 units installed iDC
boards
Connection is the same as the one of one SIU-80A/80.
n
Install the root controller BKSI-2440 to the one SIU-
80A/80, of which was connected with SMS gateway,
out of multiple SIU-80A/80 units.
1-3-2. Connection of iDC Link
Connection of one SIU-80A/80 installed iDC
boards
Set as follows the link termination switches on the
BKSI-2441 which is installed on the rear of the SIU-
80A/80 (Terminate the communication path.)
iDC LINK IN: ON
iDC LINK OUT: OFF
*1: Connected when a dual homing system (such as the FT server) is used
as the SMS gateway.
BKSI-2441
SMS gateway
SIU-80A/80 (Rear side)
Rear side
LAN connectors
RJ-45
Ethernet
switching hub
Ethernet cables
(Straight cable)
*1
12
ADDRESS
34
1
2
iDC LINK IN
Switch setting
1
2
iDC LINK OUT
100 Z
ONOFF
100 Z
ONOFF
1-7 (E)
BKSI-2440
Connection of multiple SIU-80A/80 units installed iDC boards
As an example, describes about the three SIU-80A/80 units connections.
Use the BKSI-2441 installed in the rear of each SIU-80A/80, when connecting the SIU-80A/80 units.
n
The maximum number of the connecting SIU-80A/80 units and iDC boards which are installed in
each SIU-80A/80 are depended on the installing software.
1. Install the boards to each SIU-80A/80.
Unit A : Install the BKSI-2441 to the No.1 slot in the rear of SIU-80A/80.
Install the root controller BKSI-2440 to the No.1 slot in the front of SIU-80A/80.
Unit B/C : Install the BKSI-2441 to the No.1 slot in the rear of SIU-80A/80.
(The No.1 slot in the front of SIU-80A/80 is empty.)
n
In this case, the root controller BKSI-2440 has only to install to the unit A of which is one out of
three SIU-80A/80 units. Theres no need to install the root controller BKSI-2440 to the unit B and
unit C.
(The root controller BKSI-2440 is able to control the multiple iDC boards in the one Server
Management System by the only one.)
2. Connect the SIU-80A/80 units using any cables RCC-5G, RCC-10G, and RCC-30G as shown in the
figure.
*1: Connected when a dual homing system (such as the FT server) is used as the SMS gateway.
n
The maximum total length of the cables connecting the SIU-80A/80 units is 30 m. (maximum data
transmission distance).
The cable shown in the figure 1 + 2 < 30 m
The cable shown in the figure 3 + 4 < 30 m
3. Set the link termination switches on the BKSI-2441 as shown in the figure.
n
Terminate the communication path at the start and finish (set to ON).
BKSI-2441
BKSI-2441
BKSI-2441
SMS gateway
1 RCC-5G/10G/30G cable 2 RCC-5G/10G/30G cable
3 RCC-5G/10G/30G cable 4 RCC-5G/10G/30G cable
Unit A
SIU-80A/80
(Rear side)
Unit B
SIU-80A/80
(Rear side)
Unit C
SIU-80A/80
(Rear side)
Rear side
LAN connectors
RJ-45
Ethernet
switching hub
Ethernet cables
(Straight cable)
*1
12
ADDRESS
34
12
ADDRESS
34 12
ADDRESS
34
1
2
iDC LINK IN
Switch setting
1
2
iDC LINK OUT
100 Z
ONOFF
100 Z
ONOFF
1
2
iDC LINK IN
Switch setting
1
2
iDC LINK OUT
100 Z
ONOFF
100 Z
ONOFF
1
2
iDC LINK IN
Switch setting
1
2
iDC LINK OUT
100 Z
ONOFF
100 Z
ONOFF
1-8 (E)
BKSI-2440
1-4. Information of BKSI-2440
1-4-1. Setting and Function of Switches/
LEDs on Board
n
Never change the setting of the switches shown by Facto-
ry use only.
CPU-356 board
(A side/component side)
n
( ) marks show the address on board.
..
..
. Switches
S100 (A-5): System setting (dip switch)
This switch is used for setting of the system operation.
The following figure shows the factory settings.
S100-1: ON Boot monitor
OFF Usual (factory setting)
S100-2: ON Factory use only
OFF Usual (factory setting)
S100-3 to 4: Unassigned (factory settings: OFF)
CN1300
D714
CN400
D401
S400
S700
S501
CN1201
CN1200
S100
S500
S1200
D100
D600
ND700
ND701
ND100
ND101
S1201
CN700
CN100
CN1301
CN1204
CN1203
CN1202
CN500
1
ON
234
S700 (A-4): System setting (dip switch)
This switch is used for setting of the system operation.
The following figure shows the factory settings.
S700-1: ON Boot monitor
OFF Usual (factory setting)
S700-2: ON Factory use only
OFF Usual (factory setting)
S700-3 to 4: Unassigned (factory settings: OFF)
S500 (A-5), S501 (A-4), S1202 (A-4): CPU reset (push
switch)
CPUs on the CPU-356 board are reset, when these switch
are pressed.
S500: Reset switch for IC100
S501: Reset switch for IC700
S1201: Reset switch for IC100 and IC700
S400 (A-3): Compact flash card release (push switch)
This switch is used for releasing the compact flash card.
S1200 (A-6): System setting (dip switch)
This switch is used for setting when this board uses for
root controller.
The following figure shows the factory settings.
S1200-1 to 8: Unassigned (factory settings: OFF)
1
ON
234567 8
1
ON
234
1-9 (E)
BKSI-2440
..
..
. Connectors
n
( ) marks show the address on board.
Ref No. Name Function
CN100 (A-5) Factory use only
CN500 (A-3)
CN700 (A-3)
CN1200 (A-5)
CN1201 (A-4)
CN1300 (D-1)
CN1301 (C-6)
CN400 (A-2) Compact flash card Connects the Compact flash card supplied with the main unit.
..
..
. LEDs
n
( ) marks show the address on board.
Ref No. Name Function
D100 (A-5) MAIN CPU indicator Displays the operation status for the MAIN CPU.
Blinks in green: MAIN CPU is normal.
Blinks in orange: Flash ROM is being written.
Blinks in red: Communication between route and sub boards is
abnormal, or writing error occurred in Flash ROM.
D600 (A-6) Root indicator Lights when this board is used for root controller.
D401 (A-3) Compact flash card Displays the operation status for the Compact flash card.
indicator Lights in green: Compact flash card is being connected.
Blinks in green: Compact flash card is in operation.
Blinks in red: Compact flash card is in preparation to be
connected/released.
No light: Compact flash card is ready to be relased.
D714 (A-1) IF CPU indicator Displays the operation status for the IF CPU.
. For route board
Blinks in green: IF CPU is logging in to SMS/GW.
Lights in green: IF CPU is re-logging in to SMS/GW.
Blinks in orange: IF CPU is logging out from SMS/GW.
Lights in orange: IF CPU is waiting for re-login to SMS/GW.
. For sub board
Blinks in green: IF CPU is normal.
ND100, ND101 (A-6) 7-seg indicator The indication depends on a software to be installed.
*1
ND700, ND701 (A-1)
*1: For details about the indication, refer to the file “SETUPE.WRI” in the disc supplied with the Server Management Software BSS-1.
1-10 (E)
BKSI-2440
100 Z
OFF
ON
100 Z
OFF
ON
12 12 12
iDC LINK OUT SNS GWiDC LINK IN
BKSI-2441
1
2
3
1-5. Information of BKSI-2441
1-5-1. Location and Function of Connectors
1 iDC LINK connectors (D-sub 9-pin)
These connectors are used for communications between iDC boards which are installed in multiple
SIU-80A/80 units.
2 Link termination switches
These are the link termination switches.
When this switch turns ON, the communication path is terminated.
When the SIU-80A/80 with the iDC board is one, set the iDC LINK IN to ON and the iDC LINK
OUT to OFF.
3 SMS GW connectors (8-pin modular jack)
These connectors are used for communications between SMS gateway and root controller BKSI-
2440.
Connect to the LAN connectors on the SMS gateway.
1-5-2. Connecting Connector and Cables
When connecting cable to connectors on the connector panel at the time of installing or servicing, use the
following connector, cables or equivalents.
Connectors on BKSI-2441 Matching connector/cables
Panel Indication Connector Connector/cables Sony Part No.
SMS GW 1 8-pin modular jack RJ-45
SMS GW 2 LAN cable (shield type)
*1
iDC LINK IN1 D-sub 9-pin, female D-sub 9-pin, male 1-560-651-00 (connector)
iDC LINK IN2 1-561-749-00 (shell)
iDC LINK OUT1 RCC-5G/10G/30G cables
*2
iDC LINK OUT2
*1: To prevent from the malfunction by noise, be sure to use the LAN cable of shield type.
*2: These cables are optional accessories. Each length is 5 m, 10 m, and 30 m.
1-11 (E)
BKSI-2440
1-5-3. Signal Inputs/Outputs
Input and output signals of the connectors on the connector
panel are shown below.
SMS GW 1/GW 2: 100BASE-TX (8-pin modular jack)
<External View>
Pin No. Signal
1TX+
2TX_
3RX+
4 - 5 NC
6RX_
7 - 8 NC
iDC LINK IN 1/OUT 1: D-sub 9-pin (female)
<External View>
Pin No. Signal
1NC
2 LINK OUT (+)
3 LINK IN (_)
4 GND
5 FRAME SIGNAL
6 GND
7 LINK OUT (_)
8 LINK IN (+)
9 NO REF
iDC LINK IN 2/OUT 2: D-sub 9-pin (female)
<External View>
Pin No. Signal
1NC
2 LINK IO (+)
3 GND
4 GND
5 FRAME SIGNAL
6 GND
7 LINK IO (_)
8 GND
9 NO REF
1-5-4. Switch Setting
IF-905 board
(A side/component side)
..
..
. Switches
S2000, S2001: Link termination (select switch)
S2000: ON (factory setting)
S2001: OFF (factory setting)
1
8
5
9
6
1
5
9
6
1
S2000 S2001
1-12 (E)
BKSI-2440
1-6. Information of BKSI-2042
1-6-1. Location and Function of Connectors
1
2
345
6
BKSI-2042
RS232C/422A
232C 232C 232C 232C 232C 232C
1 RS-232C/422A connectors
2 RS-232C indication slots
1 RS-232C/422A connectors (D-sub 9-pin)
These are RS-232C/422A communication connectors.
Connect the signal conforming with RS-232C, RS-422A (M), or RS-422A (S) to these connectors
depending upon the internal connection of connectors on the board.
2 RS-232C indication slots
When the internal connection connector on the board is connected to RS-232C, it can be confirmed
through this slot.
1-6-2. Connecting Connector
When connecting cable to connectors on the connector panel at the time of installing or servicing, use the
following connector or equivalent.
Connectors on BKSI-2042 Matching connector
Panel Indication Connector Connector Sony Part No.
1 D-sub 9-pin, Female D-sub 9-pin, Male 1-560-651-00 (connector)
2 1-561-749-00 (shell)
3
4
5
6
/