IKEA HOB 473/B/01 Program Chart

  • Hello! I am an AI chatbot trained to assist you with the IKEA HOB 473/B/01 Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
HOB 473 PRODUCT DESCRIPTION SHEET
DE AT
5019 619 61131
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame setting .
At the same time, press the button with the
star .
The spark plug gives out a spark that causes
the burner to ignite.
Once the burner is lit, keep the knob pressed
for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the
operation.
Important
Improper use of the grids can result in damage
to the hob: do not position the grids upside
down or slide them across the hob.
Do not use:
- cast iron griddles or terracotta pots and pans
- heat diffusers such as metal mesh, or any
other types
- two burners simultaneously for one receptacle
(e.g. fish kettle).
Note:
- Should particular local conditions of the
delivered gas make the ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
- The burner safety system serves to prevent
the emission of gas if the flame should be
extinguished accidentally (draughts,
interruptions in gas supply, dousing with
liquids, etc.).
- For Austria only:
ÖVGW Directives G 1 and G 2 and local
building regulations must be complied with.
1. Removable panstand grids
2-3-5. Medium burners
4. Large burner
6. Medium burner control knob
7. Medium burner control knob
8. Large burner control knob
9. Medium burner control knob
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/delivery
and electric ignition
Small flame
Minimum opening or
reduced delivery
DIMENSIONS OF COOKING HOB AND WORKTOP
NOTES: In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance.
(DE) CATEGORY II2ELL3B/P
INJECTORS TABLE (AT) CATEGORY II2H3B/P
* Not supplied in Austria
Type of gas used Type of
burner
Injector
marking
Rated
heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
large
medium
128
94
3.00
1.65
286 l/h
157 l/h
0.60
0.35
17 20 25
NATURAL GAS
(Methane)* G 25
large
medium
138
106
3.00
1.65
332 l/h
183 l/h
0.60
0.35
18 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G 30
large
medium
79
58
3.00
1.65
218 g/h
120 g/h
0.85
0.52
42.5 50 57.5
LIQUID
PETROLEUM GAS
(Cylinder) G 31
large
medium
79
58
2.62
1.43
187 g/h
102 g/h
0.85
0.52
42.5 50 57.5
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G 20 20 mbar 4G 7.95 757 l/h 15.9
G 20 20 mbar* 4G 7.95 881l/h 15.9
G 30 50 mbar 4G 7.95 578 g/h 15.9
G 31 50 mbar 4G 6.91 493 g/h 13.82
/