WisyCom BX2 User manual

Type
User manual
Wisycom Srl - Via Spin, 156 - I-36060 Romano d’Ezzelino (VI) - Italy
tel. +39 0424 382605 fax. +39 0424 382733 http:// www.wisycom.com - e-mail: sales@wisycom.com
Subject to change without notice
BX2 FIRBER BOX CONNECTION AND POWER MODULE
POWER INPUTS
1- AC Power Plug: 230V
2- DC Power Plug: 10-36V
3-4-5- Removable batteries: 2x Anton Bauer lithium or 2x Lead Acid Batteries
POWER OUTPUTS
Dc Power output: 12V - 2A
Hirose Output: 12V 500mA
Power interface output: customized power interface, please refer to the power interface
wiring graphic on top. Yellow and white pins are wired on all the devices connectors, while
on the output power interface only yellow pins are wired.
Wisycom Srl - Via Spin, 156 - I-36060 Romano d’Ezzelino (VI) - Italy
tel. +39 0424 382605 fax. +39 0424 382733 http:// www.wisycom.com - e-mail: sales@wisycom.com
Subject to change without notice
BATTERY MODES
Priority mode: the BX2 will use one lithium battery at the time, once the first one is over
the system will automatically move to the second. After that, if installed both, it will switch
on the Lead Acid battery
Share Mode: the BX2 will use gradually both the batteries at the same time
Caution: When you set up share mode directly on the MFLC and MPA221 while using Lead
Acid Batteries, the BX2 will consume first the secondary power input (battery) instead of
the primary (AC or DC) until the battery doesn’t fall below 24V.
This entails that if you work in Share Mode, you might not have the backup battery if
power drops. With Anton Bauer batteries the system won’t behave like this due to the fact
that those lithium batteries work at 16V.
This behavior is independent from the Share/Priority switch on the power supply module
and only refers to Lead Acid Battery.
Note: Lead Acid battery will automatically recharge using the main power inputs AC / DC,
Anton Bauer need to have their own charger.
LED INDICATORS
Red: alimentation missing
Blue: shows which alimentation is in use
Green: available alimentation but not currently in use
Orange: Lead Acid Battery in charge (through AC/DC).
  • Page 1 1
  • Page 2 2

WisyCom BX2 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI