Astria Fireplaces EDVCR/CL Instruction Sheet

Type
Instruction Sheet

This manual is also suitable for

www.IHP.US.com 126750-01A
1
750255M Rev. B 04/2015
P750255M INSTALLATION INSTRUCTIONS
ADDENDUM
DV GAS APPLIANCES
TOP AND REAR VENT COLLARS
DV GAS APPLIANCES
TOP AND REAR VENT COLLARS
INSTALLATION INSTRUCTIONS
ADDENDUM
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
P/N 750,255M
REV. A 05/2008
GENERAL INFORMATION
This Installation Instruction Addendum has been prepared to assist in the removal of the new Top and Rear Vent Cover knockout on various direct
vent gas appliances.
INSTALLATION INSTRUCTIONS
Refer to Figures 1, 1A, and 3 for top vent usage and Figure 2, 2A and 3 for rear vent usage. The following paragraphs outline the new procedure
for removal.
When the top vent collar is being used: with a rubber mallet, tap around the outside of the knockout, at the four metal tabs attaching the knockout
to the firebox wrapper. This will disconnect the knockout from the firebox wrapper. When the four tabs have been broken, remove and discard the
knockout, then remove and discard the insulation blanket from around the vent opening. The top vent is now ready to be used.
When the rear vent collar is being used: with a rubber mallet, tap around the outside of the knockout, at the four metal tabs attaching the knockout
to the firebox wrapper. This will disconnect the knockout from the firebox wrapper. When the four tabs have been broken, remove and discard the
knockout, then remove the vent cap cover and insulation blanket from around the vent opening. The rear vent is now ready to be used.
Figure 1 Figure 1A
FIREBOX TOP
CABINET TOP
VENT
COVER PLATE
TOP VENT
COVER PLATE
SECURING SCREWS
CROSS SECTION
(INSIDE UNIT)
(OUTSIDE UNIT)
INSULATION KNOCKOUT
Figure 2A
Figure 2 CROSS SECTION
LINTEL
SECURING
SCREWS
LINTEL
COVER PLATE
SECURING SCREWS
CABINET BACK
(INSIDE UNIT) (OUTSIDE UNIT)
KNOCKOUT
VENT CAP
COVER
INSULATION
PLUG
REAR
VENT
REAR KNOCKOUT
VENT CAP COVER
INSULATION PLUG
REAR VENT OPENING
TOP
KNOCKOUT
INSULA
TION
TOP VENT
OPENING
www.IHP.US.com 126750-01A
2
750255M Rev. B 04/2015
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
IHP.US.com
P750255M
The manufacturer reserves the right to make
changes at any time, without notice, in design,
materials, specifications, prices and also to
discontinue colors, styles and products. Consult
your local distributor for fireplace code informa-
tion.
Printed in U.S.A. © 2015 by Innovative Hearth
Products
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Printed in U.S.A. © 2008 by LHP
P/N 750,255M REV. A 05/2008
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
1110 West Taft Avenue
Orange, CA 92865
What if the wrong vent collar knockout was removed
In the event that the top vent collar was prepared, when the rear vent was
to be used, proceed with the directions on page one for using the rear
vent collar. Then, using the removed vent cap, attach it to the top vent
collar. To do this, bend out the two metal tabs on the sides of the vent
cap; insert the insulation plug into the top vent opening and, using two
self tapping metal screws, screw the vent cap into the top of the firebox,
over the top vent collar (refer to Figure 4 and 4A ). Tighten until the vent
cap is flush with the firebox wrapper.
If the rear vent was prepared when the top vent was to be used, proceed
with the directions above for using the top vent. Then use the vent cap
removed from the rear vent collar and re-attach it to the rear vent cap.
Do this by bending out the two metal tabs on the sides of the vent cap,
ensuring the insulation plug is in place in the vent opening, and using
two self-tapping metal screws, screw the vent cap into the rear of the
firebox, over the rear vent collar (refer to Figure 4 and 4A ). Tighten
until the vent cap is flush with the firebox wrapper.
Figure 4A
Figure 4
Figure 3
TOP
KNOCKOUT
REAR
KNOCKOUT
BEND TABS OUT
(TWO PLACES)
VENT CAP
COVER
INSULATION
PLUG
TOP VENT
OPENING
SECURE WITH TWO (2) SELFTAPPING SCREWS
Top Vent Shown - Rear Vent Similar
  • Page 1 1
  • Page 2 2

Astria Fireplaces EDVCR/CL Instruction Sheet

Type
Instruction Sheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI