Factory reset
Leaving gateway: Press
the button for 10 seconds.
The LED will ash red 5
times and then turn off . Please
use this procedure only
when the network primary
controller is missing or
otherwise inoperable!"
Auf Werkseinstellung zurücksetzen
Drücken Sie den Knopf für 10
Sekunden. Die LED wird 5 mal rot blinken
und dann ausgehen.
Bitte verwenden Sie dieses Verfahren nur,
wenn der primäre Netzwerkcontroller fehlt
oder nicht funktionsfähig ist!
Events
User Event Noti cation Type Noti cation Event
Over voltage threshold
is met
Power Management (0x08) Over-voltage detected (0x07)
Over current
threshold is met
Power Management (0x08) Over-current detected (0x06)
Over load threshold is met Power Management (0x08) Over-load detected (0x08)
Einstellungen/Fälle
Z-Wave Benutzer Kon guration
Beschreibung Wert Größe
(Byte)
1 Status wenn
Zwischenstecker
eingesteckt ist
(230 V)
0 = Aus
1 = Ein
2 = Entspricht dem
letzten Status, vor dem
Ausstecken
1 2
3 Ermöglicht die
Freigabe/ das
Sperren der
Gruppen 2 & 3
0 = Gruppen 2 & 3 sperren
1 = Gruppe 2 freigeben
2 = Gruppe 3 freigeben
3 = Gruppen 2 & 3
freigeben
1 3
5 Überspannungs-
Alarm (V)
0 = Überspannungsalarm
gesperrt
1 – 260 = Schwellenwert
Überspannungsalarm
2 0
6 Überstromalarm 0 = Überstromalarm
gesperrt
1 – 20000 = Schwellen-
wert Überstromalarm
2 0
21 Bericht Leis-
tungsschwankung
0 = Bericht gesperrt
1 – 100 = Leis-
tungsschwankung (% W),
wenn Bericht gesendet wird.
1 10
22 Überlastbericht 0 = Überlastbericht
gesperrt
1 – 3120 = 1 bis 3120 W
2 3000
23 Leistungsübertra-
gungsbericht
0 = Bericht gesperrt
1 – 65535 = 1WH bis
65535 WH
2 1000
24 Zeit-Messbericht
(Sekunden)
0 = Bericht gesperrt
30 – 65535 = Bericht zur
Lifeline geschickt
2 3600
25 Leistungsschwel-
lenwert (W) hoch
0 = Leistungsschwellen-
wert gesperrt
1 – 65535 = Leis-
tungsschwellenwert
2 3000
26 Leistungsschwel-
lenwert (W) niedrig
0 = Leistungsschwellen-
wert gesperrt
1 – 65535 = Leis-
tungsschwellenwert
2 5
27 Leistungsschwel-
lenwert Aktionen
1 = Leistungsschwellen-
wert gesperrt
2 = Leistungsschwel-
lenwert (hoch)
freigegeben mit Signal
OFF an Gruppe 4
4 = Leistungsschwel-
lenwert (hoch)
freigegeben mit Signal
ON an Gruppe 4
8 = Leistungsschwel-
lenwert (niedrig)
freigegeben mit Signal
OFF an Gruppe 5
16 = Leistungsschwel-
lenwert (niedrig)
freigegeben mit Signal
ON an Gruppe 5
1
12 (=
8+4)*
Fall Benachrichtigungstyp Benachrichtigungsvorgang
Überspannungswert ist
erreicht
Power Management (0x08) Überspannung festgestellt
(0x07)
Überspannungswert
ist erreicht
Power Management (0x08) Überstrom festgestellt (0x06)
Überlast (Leistung) ist
erreicht
Power Management (0x08) Überlast festgestellt (0x08)
Association Group
Using association group, the Smart Plug is able to command or notify another
device of a Z-Wave® network.
Durch die Nutzung der Assoziierungsgruppe, kann der Zwischenstecker an-
dere Z-Wave Produkte im Netzwerk führen oder benachrichtigen.
Assoziierungsgruppe
Group Group Name
1 Lifeline
2 Follow State
3 Follow Complementary State
4 Metering - High Threshold - Set On/O
5 Metering - Low Threshold - Set On/O
Gruppe Gruppennamen
1 Lifeline
2 Follow State
3 Follow Complementary State
4 Metering - High Threshold - Set On/O
5 Metering - Low Threshold - Set On/O
Group 1 – Lifeline
Maximum number of devices in group: 5
This group is generally used to report information of the Smart Plug to a
Main Controller of the network, including Meter, Binary Switch Report,
Noti c ation and Device Reset Locally.
Group 2 – Follow State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) using the local button,
it will send ON (respectively OFF) command to the associated devices. No
command is sent if the Smart Plug is switched ON or OFF wirelessly. This group
is con gur able through the parameter 3.
Group 3 – Follow Complementary State
Maximum number of devices in group: 5
When the Smart Plug is switched ON (respectively OFF) using the local button,
it will send OFF (respectively ON) command to the associated devices. No
command is sent if the Smart Plug is switched ON or OFF wirelessly. This group
is con gur able through the parameter 3.
Group 4 - Metering - High Threshold - Set On/O
Maximum number of devices in group: 5
When the Smart Plug reaches over the high threshold of power defi ned by the
confi uration parameter, it will send OFF or ON command to the associated
devices. This group is con gur able through the parameter 25 and 27.
Group 5 - Metering - Low Threshold - Set On/O
Maximum number of devices in group: 5
When the Smart Plug reaches below the low threshold of power defi ned
by the confi guration parameter, it will send OFF or ON command to the
associated devices. This group is confi gurable through the parameters 25 and
27.
Gruppe 1 – Lifeline
Maximale Anzahl der Komponenten in der Gruppe: 5
Die Gruppe wird generell genutzt um Informationen des
Zwischensteckers an das Gateway des Netzwerks, inklusive Messung,
binärer Schalterbericht, Benachrichtigung und lokales Reset der
Komponente zu senden.
Gruppe 2 – Follow State
Maximale Anzahl der Komponenten in der Gruppe: 5
Wenn der Zwischenstecker an der Funktionstaste geschaltet
wird, wird das Signal EIN (bzw. AUS) an ein Gateway gesendet.
Wird der Zwischenstecker jedoch per APP geschaltet wird kein Signal
unter dieser Gruppe gesendet. Diese Gruppe wird in Parameter 3 konfi
guriert.
Gruppe 3 – Follow Complementary State
Maximale Anzahl der Komponenten in der Gruppe: 5
Wenn der Zwischenstecker an der Funktionstaste geschaltet
wird, wird das Signal AUS (bzw. EIN) an das Gateway gesendet.
Wird der Zwischenstecker jedoch per APP geschaltet wird kein Signal
unter dieser Gruppe gesendet. Diese Gruppe wird in Parameter 3 konfi
guriert.
Gruppe 4 - Metering - High Threshold - Set On/Off
Maximale Anzahl der Komponenten in der Gruppe: 5
Wenn der Zwischenstecker eine Überlast (defi niert in
den Konfi gurationsparametern) erkennt, sendet er einen OFF oder ON
Befehl an das Gateway.
Diese Gruppe wird in den Parametern 25 und 27 defi niert.
Gruppe 5 - Metering - Low Threshold - Set On/Off
Maximale Anzahl der Komponenten in der Gruppe: 5
Wenn der Zwischenstecker eine Unterlast (defi niert in
den Konfi gurationsparametern) erkennt, sendet er einen OFF oder ON
Befehl an das Gateway.
Diese Gruppe wird in den Parametern 25 und 27 defi niert.
* Leistungsschwellenwert (hoch) freigegeben mit Signal ON an Gruppe 4 und
Leistungsschwellenwert (niedrig) freigegeben mit Signal ON an Gruppe 5.
Parameter Werkseinstellung