Midmark 604 Examination Table User guide

Type
User guide
Users Guide
Manual
Examination Table
For models:
604 (all)
MA706600i
Refer to compliance chart
in this manual.
English
Español
Français
Style P
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99 Rev. TA2 (5/30/19)
© Midmark Corporation 2015
English - 2
MA706500i
Model / Serial
Number Location
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Model / Serial Number:
Date of Purchase:
Midmark Authorized Service
Company [name / phone]:
Dealer [name / phone]:
Product Information
(The information below is required when calling for service)
© Midmark Corporation 2015
English - 3
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Table of Contents
Important Information
Safety Symbols ....................................................................................................................4
Warnings ..............................................................................................................................5
Intended Use ........................................................................................................................ 5
Electrical Requirements ......................................................................................................5
Electromagnetic Interference ..............................................................................................6
Disposal of Equipment ........................................................................................................6
Authorized EU Representative ...........................................................................................6
Transportation / Storage Conditions ...................................................................................6
Operation
Back Section Positioning ....................................................................................................7
Stirrups .................................................................................................................................8
Footrest & Treatment Pan ...................................................................................................9
Footstep ...............................................................................................................................9
Paper Roll & Tear Strap ....................................................................................................10
Drawer Heater (optional) ........................................................................................ 11
Pelvic Tilt (optional) ................................................................................................12
Receptacle (optional) .............................................................................................13
Upholstery Heater (optional) ...................................................................................14
Exam Assistant
®
Drawer System ......................................................................................15
Reversing the Side Drawers .............................................................................................16
Maintenance
Cleaning .............................................................................................................................17
Preventative Maintenance ................................................................................................17
Calling For Service ...........................................................................................................17
Specications
Weights & Dimensions ......................................................................................................18
Voltage, Current, Frequency Ratings & Compliance Chart ............................................19
Warranty Information
Limited Warranty ................................................................................................................20
© Midmark Corporation 2015
English - 4
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Caution
Indicates a potentially hazardous situation which may result in minor or moderate injury. It may
also be used to alert against unsafe practices.
Warning
Indicates a potentially hazardous situation which could result in serious injury.
Important Information
Safety Symbols
Equipment Alert
Indicates a potentially hazardous situation which could result in equipment damage.
Note
Ampliesaprocedure,practice,orcondition.
Protective earth ground
Fuseratingspecication
Dangerous voltage / shock hazard
TypeB,AppliedPart
(Upholstery)
Proper shipping orientation
Maximum stacking height
(palletted units)
Fragile
Keep dry
Patient Weight Limit
226 kg
500 lbs
Refer to manual
Catalogue NumberManufacturer
Serial Number
© Midmark Corporation 2015
English - 5
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Caution
To completely isolate the table from electrical mains supply, both power cords must be
unplugged.
When using high frequency surgical devices or endocardial catheters:
• Usenon-conductivematerialtoinsulatepatientfrommetalportionsofthetable.
• Consultoperatinginstructionsforthedevicebeforeusinginconjunctionwithdraweror
upholstery heater.
Failure to comply may result in electric shock or burns to patient.
Warnings
Intended Use
This product is intended to be used as a table to provide positioning and support of patients during
examinationproceduresconductedbyqualiedmedicalprofessionalsinanoceenvironment.
Electrical Requirements
Warning
Connecting equipment to the multiple socket outlet effectively leads to creating a Medical
Electrical System and the result can be a reduced level of safety.
Warning
Table must be positioned in normal use such that the power cords can be easily accessed
to unplug.
Warning
To avoid risk of electric shock, this equipment must only be connected to a supply mains with
protective earth.
Warning
Equipment is not suitable for use in
the presence of a flammable anesthetic
mixture.
Clarification: Equipment is suitable for use in the
presence of oxygen, air, or nitrous oxide.
Warning
No modification of this equipment
is allowed.
Warning
To avoid injury, do not put head or extremities under the paper tear strap.
© Midmark Corporation 2015
English - 6
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Electromagnetic Interference
This product is designed and built to minimize electromagnetic interference with other devices.
However,ifinterferenceisnoticedbetweenanotherdeviceandthisproduct:
• Removeinterferingdevicefromroom.
• Plugchairintoanisolatedcircuit.
• Increaseseparationbetweenchairandinterferingdevice.
• ContactMidmarkifinterferencepersists.
Disposal of Equipment
Attheendofproductlife,thetable,accessories,andotherconsumablegoodsmaybecomecontaminated
fromnormaluse.Consultlocalcodesandordinancesforproperdisposalofequipment,accessoriesand
other consumable goods.
Authorized EU Representative
CountriesintheEUshoulddirectallquestions,incidents,andcomplaintstoMidmark’sAuthorizedEUrepre-
sentative listed below.
Newmed Srl.
Via Lenin 79/A
QuattroCastella(RE),42020
Italy
Phone: +39.0522.875.166
Fax:+39.0522.243.096
Transportation / Storage Conditions
Ambient Temperature Range: .....................................-5°C to +38°C (+23°F to 100°F)
Relative Humidity........................................................10% to 90% (non-condensing)
Atmospheric Pressure ................................................500hPato1060hPa(0.49atmto1.05atm)
© Midmark Corporation 2015
English - 7
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Operation
Back Section Positioning
To position the back section...
A) While holding the back section in place, squeeze the
Back Release Handle (either side).
B) Move the back section to desired position.
C) Release handle to lock back section in position.
MA697500i
Back Release Handle
Max.
70° ±5°
Min.
0° ±1°
MA696700p
© Midmark Corporation 2015
English - 8
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA696300i
Stirrups
To position the stirrups...
A) Pull the stirrup out, then unfold.
B) Lift the stirrup slightly, then move it left or right as desired.
C) Release stirrup to lock in position.
Caution
Be sure the stirrups are locked in place before using.
The stirrups will not support the patient’s entire weight.
© Midmark Corporation 2015
English - 9
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA696600i
Footrest & Treatment Pan
Footstep
To access the treatment pan...
Lift footrest pad slightly, then slide pad back into table.
To extend footrest...
Pull footrest out to desired position.
To access the footstep...
Lift footstep slightly, then pull outward.
Caution
Do not use footrest to support patient’s
entire weight.
MA696401p
© Midmark Corporation 2015
English - 10
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA696800i
Paper Roll & Tear Strap
To install the paper roll...
Insert rod into sockets under head end of upholstery.
To install the paper tear strap...
Attach strap to snaps on each side of table.
Note
Up to four paper rolls may be stored under the back section.
Paper Roll Size (max.):................................................................. 21 in. wide x 3.5 in. diameter
(53 cm x 9 cm)
© Midmark Corporation 2015
English - 11
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Drawer Heater Button (white)
To turn the drawer heater ON/OFF...
Press the drawer heater button.
Drawer Heater (optional)
The drawer heater warms the contents of the drawer to approximately 98°F (37°C).
Note
The drawer heater switch illuminates when heater is ON (I).
MA697000p
© Midmark Corporation 2015
English - 12
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA702300i
Trigger
Handle
Max.
7° ±2°
Min.
1.5°
MA697500i
Pelvic
Support
Pelvic Tilt (optional)
To elevate seat section...
Lift seat until pelvic support drops into place.
To return to flat position...
A) Lift seat section slightly.
B) Pivot trigger handle upward.
C) Lower seat section.
© Midmark Corporation 2015
English - 13
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Tripped
(no power)
Reset
(power)
Receptacle (optional)
The duplex receptacle on the side of the table, provides power for accessories used during
medical procedures. There are two circuit breakers located under the seat section. If the
receptacle’s maximum load is exceeded, the circuit breakers interrupt power to the receptacle.
Maximum Load ................................................................ 5 amps
To reset circuit breaker(s)...
Push the circuit breaker toggle switch.
5
A
M
P
5
A
M
P
5
A
M
P
5
A
M
P
MA9899i
MA9894p
Circuit Breakers
© Midmark Corporation 2015
English - 14
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Equipment Alert
The maximum power loading of the heating element
is 45 W, and should only be powered by the
connection provided.
If the heated upholstery is punctured, it must be
repaired or replaced to ensure proper operation.
Upholstery Heater (optional)
Note
The upholstery heater button
illuminates when heater is ON (I).
To turn upholstery heater ON / OFF...
Press the upholstery heater button.
Note: The upholstery heater will ...
• reachoperatingtemp.in15-20minutes.
• automaticallyshutoafter8hours.
MA697000p
Upholstery Heater Button (green)
© Midmark Corporation 2015
English - 15
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA704500i
Equipment Alert
The maximum weight the shelf will support is 10 lbs (4.5 kgs).
Exam Assistant
®
Drawer System
To use the drawer front as a shelf...
Pull drawer front down to release magnetic latch.
If drawer front folds past horizontal...
Pull drawer front upward until it snaps back into the horizontal position.
© Midmark Corporation 2015
English - 16
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
MA705400i
Tabs
Reversing the Side Drawers
The side drawers can be reversed so that they open from the opposite side of the table.
Step 1: Remove side panel.
(Pull panel out from the bottom)
Step 4: Installsidepanelon
opposite side of table.
(Align panel, then push straight in)
Step 2: Remove drawer fronts.
(Pull tabs down to release)
Step 3: Installdrawerfrontson
opposite side of table.
© Midmark Corporation 2015
English - 17
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Maintenance
Cleaning
Upholstery
Washyourupholsteryweeklywithamildliquidsoapandwatermixture,rinsewithclearwater
and dry completely to remove disinfection cleaner build-up.
Disinfect your upholstery with a solution of standard bleach and water mixed 1 in 10 (10%) or chlorine based
cleaners
.
Follow this with a clear water rinse and thorough drying of material. See current CDC Guideline for
Disinfection & Sterilization in Healthcare Facilities.
Tominimizedamagecausedbydisinfectantcleanerresiduebuild-up,donotallowdisinfectantstopoolon
theupholsterysurface.Oncetheapprovedcontacttimehasbeenobtained,removeanddryexcessliquid
remaining on the surface.
Detailed care and maintenance instructions are included with your product. This information is also available
on www.midmark.comintheTechnicallibraryundertheUserInformationtabforyourproduct.
Painted Metal / Plastic Surfaces
Cleanthepaintedmetalandplasticsurfacesweeklyusingacleansoftcloth,andmildcleaner.
Preventative Maintenance
Periodically inspect the following areas:
•Powercordshouldbefreeofcutsorothervisibledamage.
•Allfastenersshouldbepresentandtightenedsecurely.
•Allmechanicalfunctionsshouldoperateproperly.
Haveaqualiedservicetechnicianinspectyourtableeverysixmonths.
Calling For Service
Ifserviceisrequired,contactyourauthorizedMidmarkdealer.
To contact Midmark directly:
1-800-MIDMARK(1-800-643-6275)
8:00 am until 5:00 pm Monday - Friday (EST) [excluding standard U.S. holidays]
© Midmark Corporation 2015
English - 18
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Maximum Patient Weight: 500 lbs (226 kg)
Paper Roll
(maximum size): (See Paper Roll & Tear Straps page)
Range of Motion & Dimensions: (See illustration below)
Weight of Table: 220 lbs (99.8 kg)
Power Cord: 6 ft. (1.8 m) long
Specications
Weights & Dimensions
MA8378i
Max.
7° ±2°
Min.
Max.
70° ±5°
Min.
1.5°
46.4 in.
(117.8 cm)
20.5 in.
(52 cm)
30.2 in.
(76.7 cm)
Up to:
16 in. (40.6 cm)
59.5 in.
(151.1 cm)
28.5 in.
(72.4 cm)
27.5 in.
(69.9 cm)
75.5 in.
(191.8 cm)
© Midmark Corporation 2015
English - 19
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
Specications (continued)
Voltage, Current, Frequency Ratings & Compliance Chart
Model Description
Electrical Ratings:
ES 60601-1
CAN / CSA
C22.2,
60601-1
CE
VAC
+/- 10%
Amps
Cycles
(Hz)
604-001 Midmark Exam Table
w/ Receptacle
115 5 50/60
604-002 Midmark Exam Table
w/ Receptacle, Pelvic Tilt,
& Drawer Heater
115 5.5 50/60
604-003 Midmark Exam Table
w/ Receptacle, Pelvic Tilt,
Drawer Heater, & Heated Upholstery
115 6.5 50/60
604-004 Midmark Exam Table - Export
w/ Pelvic Tilt
- - -
604-005 Midmark Exam Table - Export
w/ Receptacle & Pelvic Tilt
230 5 50/60
© Midmark Corporation 2015
English - 20
TP202 20-42-FO-00014 Rev A1 C2169
003-1533-99
SCOPEOFWARRANTYMidmarkCorporation(“Midmark”)warrantstotheoriginalretailpurchaserthatitwill,atMidmark’soption,repairor
replace components of the domestic and international medical products manufactured by Midmark (except for components not warranted
under “Exclusions”) that are defective in material or workmanship under normal use and service. The sole remedy under this limited warran-
tyistherepairorreplacement,atMidmark’soption,oftheapplicablecomponents.Thislimitedwarrantyshallonlyapplytodefectsthatare
reportedtoMidmarkwithintheapplicablewarrantyperiodandwhicharedeterminedtoexistuponexaminationbyMidmark,.Thiswarranty
extends only to the original retail purchaser of a product and is not transferable or assignable. Replacement components or products may
beusedand/orrefurbishedcomponentsorproducts,providedtheyareoflikequalityandspecicationsasnewcomponentsorproducts.
Midmark warrants to the original retail purchaser that during the applicable warranty period it will repair or replace software contained
within the products manufactured by Midmark (except for those not warranted under “Exclusions”) if: (1) the media on which the software is
furnished exhibits defects in material or workmanship under normal use; or (2) the software does not substantially conform to its published
specications.
APPLICABLEWARRANTYPERIODTheapplicablewarrantyperiod,measuredfromthedateofinvoicetotheoriginalretailpurchaserof
the product and shall be one (1) year for all warranted products and components.
OBTAININGWARRANTYSERVICEWarrantyservicemustbeobtainedthrougheitherMidmarkoranauthorizeddealerintheMidmark
product line for which warranty service is requested. Midmark may be contacted for warranty service inquiries or issues via email at www.
midmark.com;byphoneat1-800-MIDMARKorbymailtoMidmarkCorporation,60VistaDrive,Versailles,Ohio45380.Itistheretailpur-
chasersobligationtoarrangefordeliveryofaproducttoMidmarkoroneofitsauthorizeddealersforwarrantyservice,whichdeliveryshall
beatretailpurchasersexpense.Itisalsotheretailpurchaser’sobligationtocomplywiththewarrantyserviceinstructionsprovidedeither
by Midmark or its authorized dealer. The retail purchaser must provide Midmark with completed warranty registration information within
thirty(30)daysafterpurchaseinordertoobtainthebenetsofthislimitedwarranty.
EXCLUSIONS:ThislimitedwarrantydoesnotcoverandMidmarkshallnotbeliableforthefollowing:
(1)Defects,damageorotherconditionscaused,inwholeorinpart,bymisuse,abuse,negligence,alteration,accident,freightdamage,
negligentstorage,tamperingorfailuretoseekandobtainrepairorreplacementinatimelymanner;
(2)Productswhicharenotinstalled,used,andproperlycleanedandmaintainedasrequiredorrecommendedintheMidmark“Installation”
and/or“Installation/OperationManual”fortheapplicableproduct,includingthespeciedstructuralandoperationalenvironmentalconditions
and electrical requirements;
(3) Products considered to be of a consumable or sterile nature;
(4)AccessoriesorpartsnotmanufacturedbyMidmark;
(5)Chargesbyanyoneforadjustments,repairs,replacementparts,installationorotherworkperformeduponorinconnectionwithsuch
products which are not expressly authorized in writing in advance by Midmark;
(6) Costs and expenses of routine maintenance and cleaning; and
(7) Representations and warranties made by any person or entity other than Midmark.
(8)Matchingofcolor,grainortextureexcepttocommerciallyacceptablestandards;
(9)Changesincolorcausedbynaturalorarticiallight;
(10) Custom manufactured products;
(11)AlterationsormodicationstotheproductbyanypersonorentityotherthanMidmark;and
(12)Productsthatwouldotherwisebycoveredunderthislimitedwarranty,butareacquired:(i)fromapersonorentitythatisnotMidmark
or one of its authorized dealers; or (ii) from a Midmark dealer that is not authorized to sell the product at issue in the geographic territory
wherethepurchaserislocated,orisnotauthorizedtoselltheproductatissuewithinthemedicalmarket.
SOFTWARE;WITHRESPECTTOSOFTWARETHATISAPRODUCTORCOMPONENTTHEREOF,MIDMARKDOESNOTWARRANT
THATTHESOFTWARE:(1)ISERRORFREE;(2)CANBEUSEDWITHOUTPROBLEMSORINTERRUPTIONS;OR(3)ISFREEFROM
VULNERABILITYTOINTRUSIONORATTACKBYVIRUSESOROTHERMETHODS.
EXCLUSIVEREMEDY;CONSEQUENTIALDAMAGESDISCLAIMERMIDMARK’SONLYOBLIGATIONUNDERTHISLIMITEDWARRAN-
TYISTHEREPAIRORREPLACEMENTOFDEFECTIVEPARTS.MIDMARKSHALLNOTBELIABLEFORANDHEREBYDISCLAIMS
ANYDIRECT,SPECIAL,INDIRECT,INCIDENTAL,EXEMPLARYORCONSEQUENTIALDAMAGESORDELAYS,INCLUDING,BUT
NOTLIMITEDTO,DAMAGESFORLOSSOFPROFITSORINCOME,LOSSOFUSE,LOSSOFDATA,DOWNTIME,COVERAND
EMPLOYEEORINDEPENDENTCONTRACTORWAGES,PAYMENTSANDBENEFITS.THISDISCLAIMERSHALLSURVIVEANY
FAILUREORASSERTEDFAILUREOFTHEESSENTIALPURPOSEOFTHISLIMITEDWARRANTYORITSREMEDIESSPECIFIED
HEREIN.WARRANTYDISCLAIMERTHISWARRANTYISMIDMARK’SONLYWARRANTYANDISINLIEUOFALLOTHERWARRAN-
TIES,EXPRESSORIMPLIED.MIDMARKMAKESNOIMPLIEDWARRANTIESOFANYKINDINCLUDINGANYIMPLIEDWARRANTIES
OFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.THISWARRANTYISLIMITEDTOTHEREPAIRORREPLACE-
MENTOFDEFECTIVEPARTS.
STATUTEOFLIMITATIONSNoactionmaybebroughtagainstMidmarkforbreachofthislimitedwarranty,animpliedwarranty,ifany,orfor
anyotherclaimarisingoutoforrelatingtotheproducts,morethanninety(90)daysfollowingexpirationofthelimitedwarrantyperiod.
NOAUTHORIZATIONNopersonorrmisauthorizedtocreateorapproveforMidmarkanyotherobligationorliabilityinconnectionwith
the products.
Warranty Information
Warranty Information
Limited Warranty
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Midmark 604 Examination Table User guide