HQ Power vdpl300mf6 User manual

Category
Stroboscopes & disco lights
Type
User manual
V
D
COPER
N
COPER
N
COPER
N
COPER
N
COPER
N
USER
M
GEBRU
NOTIC
E
MANU
A
BEDIE
N
DP
N
ICUS I
V
N
ICUS I
V
N
ICUS I
V
N
ICUS I
V
N
ICUS I
V
M
ANUA
L
IKERS
H
E
D’EM
P
A
L DEL
N
UNGS
A
P
L
3
V
- DM
X
V
- LED
M
V
- MO
O
- LED
M
V
- LED
L
H
ANDL
E
P
LOI
USUA
R
A
NLEI
T
3
0
0
X
LED M
O
M
OONF
L
O
NFLO
W
M
OONFL
O
MOON
F
E
IDIN
G
R
IO
T
UNG
0M
O
ONFL
O
L
OWER
W
ER À D
E
O
WER
-
C
F
LOWE
R
G
M
F
O
WER -
4
- DMX-
G
E
L - PI
L
C
ONTRO
R
- DMX-
6
4
69 LE
D
G
ESTUU
L
OTAGE
LADO P
O
GESTE
U
D
s
RD - 46
DMX -
4
O
R DMX
U
ERT -
4
9 LEDS
4
69 LED
- 469 L
E
4
69 LED
s
E
Ds
s
V
D
1
T
o
I
m
e
n
If
T
h
b
u
d
e
2
3
D
PL300MF6
CO
P
. Int
r
o
all resid
e
m
portant
e
This
lifec
y
mu
n
sho
u
n
vironment
a
in doubt,
h
ank you fo
u
ilt-in progr
e
vice was d
a
. Saf
e
Damage c
and the d
e
A qualifie
d
Do not sw
Protect th
e
temperat
u
This devic
e
a qualifie
d
Make sur
e
this manu
a
Do not cri
m
if necessa
r
Disconnec
by the plu
Do not lo
o
Keep the
d
top of the
Note that
Mechanic
a
Keep the
d
. Gen
This devic
e
should on
l
Lighting e
f
their lives
.
Do not sh
a
Select a l
o
Use an ap
Familiaris
e
operation
unprofess
i
Be
v
elect
Kee
p
Unp
l
P
ERNI
C
r
oducti
o
e
nts of th
e
e
nvironm
e
symbol o
n
y
cle could
h
n
icipal wast
u
ld be retu
r
a
l rules.
contact y
o
r choosing
ams. Pleas
e
a
maged in
e
ty Ins
t
aused by
d
e
aler will n
o
d
technicia
n
itch the de
e
device a
g
u
re.
e
falls und
e
d
person ca
e
that the a
a
l.
m
p the po
w
r
y.
t the devic
g only.
o
k directly
a
d
evice awa
y
device.
damage c
a
a
l wear is n
d
evice awa
y
eral G
u
e
is design
e
l
y be used
f
fects are
n
.
a
ke the de
v
o
cation wh
e
propriate s
e
yourself
w
by unquali
f
i
onal use o
f
v
ery careful
troshocks.
p
this devi
c
l
ug the ma
i
C
US IV
o
n
e
Europea
e
ntal info
r
n
the devic
e
h
arm the
e
e; it shoul
d
r
ned to yo
u
o
ur local
w
HQPOWE
R
e
read the
transit, do
n
t
ructio
n
d
isregard o
f
o
t accept r
e
n
should in
s
vice on im
m
g
ainst dam
a
e
r protecti
o
rry out the
vailable vo
w
er cord a
n
e from the
a
t the light
y
from spl
a
a
used by u
s
ot covered
y
from chil
d
u
idelin
e
e
d for prof
e
indoors an
d
n
ot design
e
v
ice. Avoid
e
re the dev
afety cabl
e
w
ith the fu
n
f
ied people
f
the devic
e
during th
e
c
e awa
y
fro
i
ns lead be
f
VD
– DMX
n Union
r
mation a
b
e
or the pa
c
e
nvironmen
d
be taken
u
r distribut
o
w
aste dis
p
! The CO
P
manual th
o
n
't install o
r
n
s
f
certain g
u
e
sponsibili
t
s
tall and s
e
m
ediately
a
a
ge by lea
v
o
n class I.
I
electric c
o
ltage does
n
d protect i
mains to
c
source as
a
shing and
s
er modific
a
by warran
d
ren and u
e
s
e
ssional us
d
connecte
e
d for perm
brute forc
e
ice is prot
e
e
to fix the
n
ctions of t
. Any dam
a
e
.
e
installatio
m rain an
d
f
ore openi
n
3
PL300
M
LED M
O
b
out this
p
c
kage indi
c
t. Do not
d
to a speci
a
o
r or to a l
o
p
osal aut
h
P
ERNICUS
o
roughly b
e
r
use it and
u
idelines in
t
y for any
e
e
rvice this
d
a
fter it has
v
ing it swit
c
I
t is theref
o
o
nnection.
not excee
d
t against d
c
lean it or
w
sensitive p
dripping li
q
a
tions to t
h
ty.
nauthorise
e on stage
,
d to an alt
e
anent ope
r
e
when ins
t
e
cted again
device (e.
g
he device
b
a
ge that m
n: touchin
g
d
moisture.
n
g the hou
s
M
F6
O
ONFL
O
p
roduct
ates that
d
d
ispose of t
a
lized com
p
o
cal recycli
h
orities.
IV is a po
w
e
fore bringi
n
contact y
o
this manu
a
e
nsuing de
f
d
evice.
been expo
c
hed off un
o
re essenti
a
d
the volta
g
amage. Ha
w
hen it is n
eople may
q
uids. Nev
e
h
e device i
s
d users.
,
in discos,
e
rnating cu
r
ation: reg
u
t
alling or o
p
st extrem
e
g
. VDLSC7
b
efore actu
ay occur w
g
live wire
s
s
ing.
O
WER
d
isposal of
t
he unit (or
p
any for re
c
ng service.
w
erful RGB
L
n
g this dev
i
o
ur dealer.
a
l is not co
v
f
ects or pr
o
sed to cha
n
til it has r
e
a
l that the
g
e stated i
n
ve an aut
h
ot in use.
H
go into ep
i
e
r put obje
c
s
not cover
e
theatres,
e
rrent of 2
3
u
lar operat
i
p
erating th
e
heat, dus
t
or VDLSC
8
ally using i
ill most pr
o
s
can caus
e
469 L
t
he device
batteries)
c
ycling. Thi
Respect t
h
L
ED moonfl
i
ce into ser
v
v
ered by t
h
o
blems.
n
ges in te
m
e
ached roo
m
device be
e
n
the speci
f
h
orised dea
H
andle the
i
leptic seiz
u
c
ts filled w
i
e
d by the
w
e
tc. The V
D
3
0VAC/50H
z
i
on breaks
e device.
t
and mois
t
8).
t. Do not
a
o
bably be
d
e
life-threa
t
HQPOW
E
EDs
after its
as unsorte
s device
h
e local
ower with
v
ice. If the
h
e warrant
y
m
perature.
m
e
arthed. H
a
f
ications of
ler replace
power cor
d
u
re if they
d
i
th liquid o
n
w
arranty.
D
PL300M
F
z
.
will prolon
g
t
ure.
a
llow
d
ue to
t
ening
E
R™
d
y
a
ve
it
d
d
o.
n
F
6
g
V
D
4
1.
2.
3.
4.
5.
6.
7.
5
a
)
b
)
6
S
e
E
N
1
2
3
D
PL300MF6
Use the o
r
All modifi
c
Only use
t
electrosh
o
. Des
DMX outp
u
DMX inpu
t
power out
power inp
u
sound sen
micropho
n
DIP switc
h
. Ins
t
)
Mountin
g
Have the
d
norms.
The carryi
without d
e
The instal
l
Never sta
n
qualified t
e
Install the
Overhead
installatio
n
attempt t
o
result in i
n
Adjust th
e
Make sur
e
Have a qu
Connect t
h
The instal
l
)
Fuse Rep
Only fit or
Replace a
1. Rem
2. Rem
3. Repl
a
. Op
e
e
lect the co
N
TER butto
n
Stand-Al
o
r
iginal pac
k
c
ations of t
h
t
he device
f
o
cks, crash
,
criptio
n
u
t
t
put
u
t
sitivity adj
u
n
e
h
es
t
allatio
n
g
the Devi
c
d
evice inst
a
ng constru
c
e
forming.
l
ation mus
t
n
d directly
e
chnician
c
device in
a
mounting
r
n
material
t
o
install th
e
n
juries.
e
desired in
e
there is n
o
alified elec
h
e device t
o
l
ation has
t
lacement
replace a
f
blown fus
e
ove the fu
s
ove the ol
d
a
ce the fu
s
e
ration
ntrol mod
e
n
. See me
n
o
ne Mode
k
aging if th
e
h
e device
a
f
or its inte
n
,
etc. Usin
g
n
u
stment k
n
n
c
e
a
lled by a
q
c
tion must
t
always b
e
below the
d
c
heck the d
a
location
w
r
equires e
x
t
o be used
e
device yo
u
clination a
n
o
flammabl
trician car
r
o
the main
s
t
o be appr
o
f
use when
e
with a fu
s
s
e holder u
d
fuse and
i
s
e holder.
e
using the
n
u on page
Red dimm
e
Green dim
m
Blue dimm
e
device is
a
re forbidd
e
n
ded purpo
g
the devic
e
n
ob
q
ualified p
e
be able to
e
secured
w
d
evice wh
e
evice once
w
ith few p
a
x
tensive ex
Have th
e
u
rself if yo
u
n
gle via th
e
e material
r
y out the
e
s
with the
p
o
ved by an
the device
s
e of the sa
nder the p
o
i
nstall a ne
and
b
2.
e
r
m
er
er
4
to be tran
s
e
n for safe
t
se. All oth
e
e
in an una
e
rson, resp
e
support 1
0
w
ith a seco
n
e
n it is bein
a year an
d
a
ssers-by t
h
perience:
c
e
material
a
u
lack thes
e
mounting
within a 0.
e
lectric con
p
ower plug
expert bef
o
is unplugg
me type a
n
o
wer sock
e
w one.
b
uttons on
s
ported.
t
y reasons.
e
r uses ma
y
uthorised
w
e
cting EN
6
0
times the
n
dary attac
g mounted
d
once bef
o
h
at is inacc
c
alculating
w
a
nd the de
v
e qualifica
t
bracket a
n
5m radius
nection.
. Do not c
o
o
re the de
v
ed from th
e
n
d rating:
e
t at the ba
the contro
y
lead to s
h
w
ay will vo
i
6
0598-2-1
7
weight of
t
hment e.g.
, removed
o
re you bri
n
essible to
u
w
orkload li
v
ice itself c
h
t
ions as im
p
n
d tighten
t
of the dev
i
o
nnect it to
v
ice is take
n
e
mains.
ck of the d
l panel. En
h
ort circuit
s
i
d the warr
a
7
and all ot
h
t
he device
a safety c
or service
d
n
g it into s
e
u
nauthoris
e
mits, dete
r
h
ecked reg
p
roper inst
a
t
he bracke
t
i
ce.
a dimmin
g
n into serv
i
evice.
ter the mo
d
HQPOW
E
s
, burns,
a
nty.
h
er applica
for 1 hour
a
ble.
d
. Have a
e
rvice.
e
d persons
.
r
mining th
e
ularly. Do
n
a
llation m
a
t
screws.
g
pack.
i
ce.
d
e using t
h
E
R™
ble
.
e
n
ot
a
y
h
e
VDPL300MF6 HQPOWER™
5
Auto Mode
1
Flash
2 Automatic fade in and fade out
3 Automatic 7-colour change
4 Chase lights
5 Chase lights speed
Sound-Active Mode
1
Sound chase lights
2 Sound 7-colour flash
3 Se00~Se15
Master/Slave Mode
1 Master Choose mode (stand-alone, auto, sound-active)
2 Slave
7. DMX512 Mode
When operating the VDPL300MF6 through a DMX controller, you can create your own programs
and tailor them to your own needs. Each individual fixture is controllable through a standard DMX
controller. To run your projector in DMX mode, connect a controller using a standard DMX cable.
Press MODE until D.XXX is displayed. Set the DMX address.
Detailed DMX Values per Channel
Channel Function From To Description
1 LED control
0 9 LED off
10 199 Macro 1 ~ macro 38
200 239 Flash 1 ~ 11Hz
240 255 LED on
2 Speed 0 255 Slow to fast macro/flash
3 ~ 9
Single gobo
0 63 Static gobo
64 255 Gobo chase
Single gobo 0 255 Static gobo
10 Sound control
0 127 Control channel 1 ~ 9
128 255 Sound control
DMX512 Connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side
to the male 3-pin XLR input of the VDPL300MF6. Multiple VDPL300MF6s can be linked through
serial linking. The linking cable should be a two-core screened cable with XLR input and output
connectors.
DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has
to run a long distance or is in an electrically noisy environment (e.g. discos).
The terminator prevents corruption of the digital control signal by electrical
noise. The DMX terminator is simply an XLR plug with a 120 resistor
between pins 2 and 3, which is then plugged into the XLR output socket of
the last device in the chain. Please see illustrations.
VDPL300MF6 HQPOWER™
6
DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the
signals. This start address is the channel number from which the device starts to “listen” to the DMX
controller. Enter the correct number and read it from the display located on the base of the
VDPL300MF6.
You can use the same starting address for a whole group of devices or enter an individual one for
every device.
When all devices have the same address, all the VDPL300MF6s will “listen” to the control signal on
one particular channel. In other words: changing the settings of one channel will affect all devices
simultaneously. If you set different addresses, each device will “listen” to a separate channel
number. Changing the settings of one channel will only affect the device in question.
In the case of the 10-channel VDPL300MF6, you will have to set the start address of the first
VDPL300MF6 to 1, the second VDPL300MF6 to 11 (1 + 10), the third to 21 (11 + 10) and so on.
8. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling,
suspension, trussing) should not be deformed, modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician
maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
9. Technical Specifications
Power Supply 230VAC/50Hz
Power Consumption 50W
DMX Channels 10
DMX Connections 3-pin XLR
LEDs 469 x 5mm
Dimensions 800 x 700 x 800mm
Total Weight 5kg
Use this device with original accessories only. Velleman Components nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.hqpower.com. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman Components
nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or
reduced to any electronic medium or otherwise without the prior written consent of the copyright
holder.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

HQ Power vdpl300mf6 User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI