Model R57 & R59 Instructions
2005, Shure Incorporated
27E2585 (Rev. 9)
Printed in U.S.A.
CA RTRIDGE
TRAN SFORMER
XL R C ONNE CTO R
GREEN
YELLOW RED
BLUE
BLACK
2
1
3
+
BLACK
(If Applicable)
Model R57 & R59 Instructions
IMPORTANT: Twist the cartridge three times counterclockwise before screwing
the cartridge onto the case. This prevents strain on the wires.
Remove and attach the new cartridge using a soldering iron as shown.
The GREEN wire attaches to the terminal next to the embossed plus (+) sign
(or single-digit number).
plus (+) sign
Green
Yellow
3 X
NOTE: On older models, there may be a third,
black wire. Connect this wire to the case ground
nut between the green and yellow terminals on
the cartridge.