Description
The release includes updated firmware for DAT 160 SAS tape drives.
HP StorageWorks Librar y and Tape Tools (HP L&TT) must be used to download firmware to the tape drive.
Drive firmware version: WS86
Update recom
mendation
Recommended
Supersedes WS77
Product models
• HP StorageWorks DAT 160 SAS Internal Q1587A
• HP StorageWorks DAT 160 SAS External Q1588A
Operating s
ystems
• Operating systems supported by HP StorageWorks Library & Tape Tools. See
h
ttp://www.hp.com/support/tapetools.
Languages
• English (American)
• English (International)
Driveresetissuewithqueuedcommands
The error was occurring because DDS tape drives do not support command queuing. If software
applications issued inquiry commands whilst a rewind or space command was being performed, the
previous firmware could not execute an inquiry command before the command timed out. Since timeouts
are normally indicative of a more serious problem, the HBA then issued a hard reset which also aborts
the rew
ind (or space command).
The new firmware has been modified to execute an inquiry command while a rewind (or space) is
in progress.
Missing Filemark (FM) when reading
All records in the sequence were returned correctly but the Filemark was sometimes ignored. This issue
has now been fixed.
Pressing Eject hangs drive after 17.4 days inactivit y
If there is a cartridge in the drive and there has been no tape activity for a m inimum of 17.4 days, the
READY LED will flash continuously when the Eject button is pressed and there will be no attempt by the
driv
etoejectthetape.AllSCSIcommandswillhang.Thedrivewillremaininthisstateforafurther17.4
days when the cartridge will be ejected.
This problem has now been fixed.
HP StorageWorks DAT 160 SAS Tape Drives release notes
3