Programming Steps
WARNING: DO NOT PRESS RESET BUTTON WHILE
PROGRAMMING OR THE ENTIRE PROGRAM WILL BE
LOST
.
SET OR MODIFY
THE TIME OF DAY:
1.
Turn selector switch to “SET”.
2. Press the numbered button corresponding to the day. For
examaple press ´2´ for Monday.
3. Enter the current time of day. For example, if the time is
8:00 AM press 800 and press “AM”.
4. For our example, the display will show: “2 ‘8:00”.
5. Press “CLOCK” button.
6.
The display will now show: “- --:--.”
7.
To verify that the correct time is set, turn the selector
switch to “AUT
O” or “MAN”. If the time is incorrect repeat
steps 1-6.
8. Turn selector switch to “SET”.
PREPARE “ON” AND “OFF” SET POINTS FOR
PROGRAMMING.
1. List all desired ON and OFF set points as shown in the
example.
Example: The lighting load must switch ON when dark-
ness is sensed after 8:00 AM anytime from Monday thru
Saturday. The load must switch OFF at 11:00 PM
Monday thru Thursday and OFF at 2:00 AM on Friday
and Saturday (actually Saturday and Sunday morning).
DAY TIME AM/PM ON/OFF
2 (Mon) 8:00 AM ON
2 (Mon) 11:00 PM OFF
Since Tuesday thru Thursday repeat Monday the
COPY feature can be used. Refer to example 2 to follow.
6 (Fri) 8:00 AM ON
7 (Sat) 2:00 AM OFF
7 (Sat) 8:00 AM ON
1 (Sun) 2:00 AM OFF
Complete the above list for all on/off set points.
2. Now list all days to be repeated(exactly) from days
already programmed.
Example:Tuesday, Wednesday and Thursday repeat
Mondays schedule.
Day To Repeat ON Day Being Repeated
3 (Tue) ON 2 (Mon)
4 (Wed) ON 2 (Mon)
5 (Thu) ON 2 (Mon)
NOTES:
1. Any day can repeat any programmed day. A repeat day
may not be repeated.
2. If a day already has a program, it cannot repeat another
days cycle unless the scheduled events for that day
are removed.
3. If a day being repeated has a program change, the day
repeating it will recognize that change
automatically.
ENTER THE PROGRAM
1. Enter the program in the exact order:
Day; Time; AM/PM; ON/OFF
Example; for above listed on/off set pts.
Press 2 800 AM ON
Displays 2 --:-- 2 -8:00 2 ´8:00 - --:--
Press 2 1100 PM OFF
Displays 2 --:-- 2
-
11:00 2 ,11:00 - --:--
Press 6 800 AM ON
Displays 6 --:-- 6 -8:00 6 ´8:00 - --:--
Press 7 200
AM OFF
Displays 7 --:-- 7 -2:00 7 ´2:00 - --:--
Press 7 800 AM ON
Displays 7 --:-- 7 -8:00 7 ´8:00 - --:--
Press 1 200 AM OFF
Displays 1 --:-- 1 -2:00 1 ´2:00 - --:--
NOTE:
AM is indicated as ˝ ´ ˝ flashing.
PM is indicated as ˝ ‚ ˝ flashing.
2. Enter the program for repeat cycles.
Example; for above listed repeat cycles:
Press 3 ON 2
Displays 3 --:-- 3 --:-- - --:--
flashing
Press 4 ON 2
Displays 4 --:-- 4 --:-- - --;--
flashing
Press 5 ON 2
Displays 5 --:-- 5 --:-- - --:--
flashing
3. The program is now complete. It is suggested that the
program be reviewed before activating the loads. Follow
the procedures shown in “REVIEW”.
REVIEW
1. Turn the selector switch to “REVIEW”.
2. Press the button corresponding to the day being
reviewed.
3. The display will show one of the following:
• Example: Press 3;3 -2:-- (Tuesday “3” repeats
Monday “2”)
or
• Example: Press 2;--:-- (Monday events can be re-
viewed). In the second example, each time the “ON”
button is pressed, the correct time for that operation
will appear. Likewise each time “OFF” is pressed, off
times will be displayed. Continue pressing ´ON´ and
´OFF´ until ˝- --:--˝ is displayed thus indicating all
possible setpoints have been reviewed.
To modify a set point, that set point must first appear on the
display. Next, the clear button is pressed. Display will then
show ˝- --:--˝ indicating that setpoint has been removed.
Turn the selector switch to “SET” and enter the new infor-
mation in the correct order (day; time; AM/PM; ON/OFF).
COUNTING SET POINTS
Count each on and off set point. Our example would total 6.
Do not count repeat daily schedules. Up to 28 on or off set
points can be programmed. The display would show
“E EE:EE” if you tried to program the 29th set point.
OPERATION (Automatic)* (See Note* Bottom of Page 2)
1. Turn selector switch to “AUTO”.
2. Apply voltage to loads.
NOTE: When in automatic operation, if the “ON” or “OFF”
buttons are pressed, the loads will activate accordingly.
The load will stay in this condition until the next
programmed event.
BATTERY POWERED CARRYOVER
If the power goes out, the batteries will maintain the pro-
gram and keep the correct time to within .01%, for a period
of 24 hours. In order to achieve 24 hours of carryover
, the
batteries need to have been charged for at least 24 hours.
Battery recharging is automatic when the timer is in opera-
tion.
CAUTION: USE ONL
Y
NICKEL CADMIUM RECHARGE-
ABLE BATTERIES, AA SIZE, RATED 1.25 VOLTS. DO
NOT
USE
ANY
OTHER
TYPE OF BA
TTER
Y
.
While under battery power, normally “open” loads will not
activate. The timer will recognize the set points and keep
the time of day. As batteries are depleted, the display will
dim and go out, but the program and time may still be main-
tained. Once power returns, if the display shows the correct
time, the time and program have been retained.
T
o reset the
time of day
, refer to the section SET OR MODIFY THE TIME
OF DAY.
-3-
CAUTION
When installing batteries
observe correct polarity.
+
+
+
+