Danfoss PVEA User guide

Type
User guide

This manual is also suitable for

COMPLIANT
TM
CONNECTOR MATES
WITH DEUTCH
CONNECTOR #DTM-06-125A
PIN #1
INDICATED
1
12
6
7
47.1 mm
[1.85]
51.6 mm
[2.03]
LED INDICATOR
LIGHTS
CONNECTOR MATES
WITH DEUTCH
CONNECTOR #DTM-06-125A
1
12
6
7
97.0 mm
[3.82]
142.0 mm
[5.59]
144.5 mm
5.69
158.2 mm
6.23
2x 25.2 mm
[1.0]
2x
7.0
[.28]
MOUNTING
DIRECTION
#2
PLUS+1
GUIDE
Software
PLUS+1 Compliant
S4 PVE A H S
Function Block
User Manual
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
2
11020635
·
Rev DA
·
November 2012
About this Manual
Organization
and Headings
T
o help you quickly find information in this manual, the material is divided into sections,
topics, subtopics, and details, with descriptive headings set in red type. Section titles
appear at the top of every page in large red type.
In the PDF version of this document, clicking an item underlined in blue italic type jumps
you to the referenced page in the document.
Special Text Formatting Controls and indicators are set in bold black type.
Table of Contents
A Table of Contents (TOC) appears on the next page. In the PDF version of this document,
the TOC entries are hyperlinked.
Revision History
Revision Date Comment
Rev DA November 2012
©2012 Sauer-Danfoss. All rights reserved.
Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material.
Sauer-Danfoss reserves the right to alter its products without prior notice. This also applies to products already
ordered provided that such alterations can be made without affecting agreed specifications.
All trademarks in this material are properties of their respective owners.
PLUS+1, GUIDE, and Sauer-Danfoss are trademarks of the Sauer-Danfoss Group. The PLUS+1 GUIDE, PLUS+1
Compliant, and Sauer-Danfoss logotypes are trademarks of the Sauer-Danfoss Group.
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
Contents
S4_PVE_A_H_S Function Block ...................................................................................................................... 4
Overview ......................................................................................................................................................... 4
Inputs ............................................................................................................................................................... 4
Outputs ............................................................................................................................................................ 5
About Function Block Connections...................................................................................................... 6
Status and Fault Logic ............................................................................................................................... 7
About the Threshold and Maximum Values ..................................................................................... 8
Setup Inputs .................................................................................................................................................. 9
MC ControllerInput Configuration ................................................................................................. 10
How to Configure a DigIn .............................................................................................................. 10
How to Configure a DigAn ............................................................................................................ 11
How to Configure a MFIn ............................................................................................................... 12
MC ControllerOutput Configuration ............................................................................................. 13
How to Configure a MFOut ........................................................................................................... 13
How to Configure a DigOut .......................................................................................................... 14
SC ControllerInput Configuration .................................................................................................. 15
How to Configure a DigAn ............................................................................................................ 15
How to Configure a MFIn ............................................................................................................... 16
SC ControllerOutput Configuration .............................................................................................. 17
How to Configure a MFOut ........................................................................................................... 17
How to Configure a DigOut .......................................................................................................... 18
How to Power Two or More PVE-Type Valve Actuators from a Single DigOut .................. 19
11020635
l
Rev DA
l
November 2012
3
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
Overview
This function block controls the output of a Sauer-Danfoss PVEA, PVEH, or PVES valve
actuator.
If you want to:
Power two or more PVE-type actuators from a single DigOut, see How to Power Two or
More PVE-Type Valve Actuators from a Single DigOut on page 19.
Power two or more PVE-type actuators from a single MFOut on an MC controller, you
must use a PVE_Power_MF function block for power management.
For more information about this function block, refer to the Plus+1 Compliant PVE
Power MF Function Block User Manual (Sauer-Danfoss part 11007213).
See About Function Block Connections on page 6 for more about this function block’s
signals and connections.
Inputs
Function Block Inputs
Input Type Range Description
Enable BOOL —— Enables the function block’s Output.
T = Enables the Output.
F = Disables the Output.
Fdbk BOOL —— Reports a short circuit in the output used by the function block.
Error_Pin BOOL —— Monitors the input from the valve actuator’s Error_Pin.
The valve actuator outputs a T if an error occurs in the actuator.
By default, a T turns off the function block’s Output.
Thld U16 0–10000 Sets the threshold values of Output produced by Input commands of 1 and +1.
Set as a percentage of upper and lower range of the Output.
10000 = 100.00%.
4
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
Function Block Inputs
Input Type Range Description
Input S16 ±10000 Specifies the requested Output.
+10000 = Commands the full travel of the valve actuator spool in Direction B.
0 = Commands the valve actuator or spool to a neutral position.
10000 = Commands the full travel of the valve actuator spool in Direction A.
Outputs
Function Block Outputs
Output Type Range Description
Status U16 —— Reports the status of the function block.
This output follows the standard bitwise scheme described in the Basic Function Blocks Library User’s Manual
(Sauer-Danfoss part 10103408).
Fault U16 —— Reports function block faults.
This output follows the standard bitwise scheme described in the Basic Function Blocks Library User’s Manual
(Sauer-Danfoss part 10103408).
Supply BOOL —— Controls the MFOut or DigOut that supplies power to the Power pin on a valve actuator.
AND the Supply output with the SOS output when you use a single MFOut or DigOut to supply power to
two or more valve actuators.
T = Requests power on.
F = Requests power off.
SOS BOOL —— Not required when you control a just one valve actuator.
AND the SOS output with the Supply output when you use a single MFOut or DigOut to supply power to
two or more valve actuators.
T = Requests power on.
F = Requests power off.
Output S16 2500-7500 Outputs a bus with an OutputValue signal that commands the valve actuator.
11020635
l
Rev DA
l
November 2012
5
About Function Block Connections
Function Block Connections
Item Description
1 A T input enables the function block’s Output.
2 Reports the status of the MFOut used by the Output.
3 Reports the status of the Error_Pin on the valve actuator.
4 Sets the threshold Output value produced by an Input of ±1. The Thld value is a percentage of the
upper and lower Output ranges.
5 Input for an S16 signal that commands the Output.
6 Reports the status of the function block.
7 Reports function block faults.
8 Powers the valve actuator.
AND this output with the SOS output when you use a single MFOut or DigOut to supply power to two
or more valve actuators.
9 AND this output with the Supply output when you use a single MFOut or DigOut to supply power to
two or more valve actuators.
No connection is needed when you control a just one valve actuator.
10 Commands the valve actuator.
6
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
Status and Fault Logic
Status Logic
Status Bit* Reported While
Parameters are corrupt. 3 Thld < 0 or > 10000.
*Position of set bit in a 16 bit fault or status code. Bit 1 is the least significant bit. Bit 16 set to 1 identifies a standard Sauer-Danfoss status code or fault
code.
Output outputs an OutputValue signal that goes from 2500 to 7500. This signal
commands the valve actuator.
Fault Logic
Fault Cause Bit* Response Delay
Latch
Correction
Input value too low. Input < 10000. 1
OutputValue
holds at
5000.
No. No. Fix the Input.
Input value too high. Input > +10000. 2
Short circuit. Measured Ω < (Nominal Ω ÷ 3). 4
Yes. Yes.
Check for a short circuit or low
resistance between the output pin and
ground.
Hardware.
T input to the Error_Pin indicates
an error in the valve actuator.
6
Check for an open circuit or high
resistance between the output pin and
ground.
*Position of set bit in a 16 bit status or fault code. Bit 1 is the least significant bit. Bit 16 set to 1 identifies a standard Sauer-Danfoss status code or
fault code.
A delayed fault is reported if the detected fault condition persists for a specified delay time. A delayed fault cannot be cleared until the fault
condition remains undetected for the delay time.
The function block maintains a latched fault report until the latch releases. The function block attempts a release each time the Error_Pin is F
while the Input returns to 0.
11020635
l
Rev DA
l
November 2012
7
About the Threshold and Maximum Values
The function block outputs a bus with an OutputValue signal. This signal commands the
valve actuator.
The following illustration shows a plot of OutputValue between its minimum, threshold,
and maximum values.
The range of the OutputValue is 5000, going 2500 above and below a midpoint of
5000.
In this plot, the Thld value is 10% of the 2500 value (250).
As soon as the Input is +1, the OutputValue jumps to its Direction A threshold value
of 5250.
When the Input is +10000, the OutputValue reaches its full Direction A output value
of 7500.
As soon as the Input is 1, the OutputValue jumps to its Direction B threshold value
of 4750.
When the Input is 10000, the OutputValue reaches its full Direction B output value
of 2500.
8
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
Setup Inputs
As needed, enter the function block to change the FaultReaction and SuppTimeAtNeu
(Supply Time at Neutral) responses.
Setup
Inputs
Output Type Range Description
FaultReaction BOOL —— An error at the valve actuator causes the function block’s Error_Pin input to go T.
The value set here determines the function blocks response to a T on its Error_Pin input.
T = The function block disables its Output.
F = The function block does not disable its Output.
SuppTimeAtNeu S16 0-30000 The amount of time that Supply stays on after the function block’s Output returns to neutral.
1 = Supply is always on.
1000 = 1000 ms.
11020635
l
Rev DA
l
November 2012
9
MC ControllerInput Configuration
Valve actuators have an Error_Pin output. You can route this output to the function
block’s Error_Pin input through either a DigIn, a DigAn, or a MFIn.
How to Configure a DigIn
You must configure a DigIn to accept the signals from the valve actuator’s Error_Pin.
1. In the GUIDE template, enter the Inputs page.
2. Enter the DigIn that receives the input from the valve actuator’s Error_Pin.
3. Make the changes that are shown in the preceding figure.
10
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
How to Configure a DigAn
You must configure a DigAn to accept the signals from the valve actuator’s Error_Pin.
1. In the GUIDE template, enter the Inputs page.
2. Enter the DigAn that receives the input from the valve actuator’s Error_Pin.
3. Make the changes that are shown in the preceding figure.
11020635
l
Rev DA
l
November 2012
11
How to Configure a MFIn
You must configure a MFIn to accept the signals from the valve actuator’s Error_Pin.
1. In the GUIDE template, enter the Inputs page.
2. Enter the MFIn that receives the input from the valve actuator’s Error_Pin.
3. Make the changes that are shown in the preceding figure.
12
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
MC ControllerOutput Configuration
You route this function block’s:
Output to a MFOut.
Supply output to a DigOut.
How to Configure a MFOut
You must configure a MFOut to accept the signals from the function block’s Output.
1. In the GUIDE template, enter the Outputs page.
2. Enter the MFOut that receives the function block’s Output.
3. Make the changes that are shown in the preceding figure.
11020635
l
Rev DA
l
November 2012
13
How to Configure a DigOut
You must configure a DigOut to accept the signals from the function block’s Supply
output.
1. In the GUIDE template, enter the Outputs page.
2. Enter the DigOut that receives the function block’s Supply output.
3. Make the changes that are shown in the preceding figure.
14
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
SC ControllerInput Configuration
Valve actuators have an Error_Pin output. You can route this output to the function
block’s Error_Pin input through either a DigAn or a MFIn.
How to Configure a DigAn
You must configure a DigAn to accept the signals from the valve actuator’s Error_Pin.
1. In the GUIDE template, enter the Inputs page.
2. Enter the DigAn that receives the input from the valve actuator’s Error_Pin.
T
Not all DigAn inputs have a Direction configuration. The DigAn input that you modify
may not have a Direction configuration.
3. Make the changes that are shown in the preceding figure.
11020635
l
Rev DA
l
November 2012
15
How to Configure a MFIn
You must configure a MFIn to accept the signals from the valve actuator’s Error_Pin.
1. In the GUIDE template, enter the Inputs page.
2. Enter the MFIn that receives the input from the valve actuator’s Error_Pin.
3. Make the changes that are shown in the preceding figure.
16
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
SC ControllerOutput Configuration
You route this function block’s:
Output to a MFOut.
Supply output to a DigOut.
How to Configure a MFOut
You must configure a MFOut to accept the signals from the function block’s Output.
1. In the GUIDE template, enter the Outputs page.
2. Enter the MFOut that receives the function block’s Output.
3. Make the changes that are shown in the preceding figure.
11020635
l
Rev DA
l
November 2012
17
How to Configure a DigOut
You must configure a DigOut to accept the signals from the function block’s Supply
output.
1. In the GUIDE template, enter the Outputs page.
2. Enter the DigOut that receives the function block’s Supply output.
3. Make the changes that are shown in the preceding figure.
18
11020635
l
Rev DA
l
November 2012
PLUS+1 Compliant S4 PVE A H S Function Block
User Manual
S4_PVE_A_H_S Function Block
How to Power Two or More PVE-Type Valve Actuators from a Single DigOut
Use the following figure as a guide if you want to power two or more PVE-type valve
actuators from a single DigOut.
Function Block Connections
Item Description
1 Commands.
2 All Supply outputs route to an OR component.
3 All SOS outputs route to an AND component.
4 This AND output goes T when all Supply outputs are T and at least one SOS output is T.
5 To the Power pins on all valve actuators.
6 To the Output pin on a valve actuator.
T You must use a PVE_Power_MF function block if you want to power two or more PVE-
type valve actuators from a single MFOut on an MC controller. For more information,
refer to the Plus+1 Compliant PVE Power MF Function Block User Manual (Sauer-Danfoss
part 11007213).
11020635
l
Rev DA
l
November 2012
19
Products we offer:
Bent Axis Motors
Closed Circuit Axial Piston Pumps
and Motors
Displays
Electrohydraulic Power Steering
Electrohydraulics
Hydraulic Power Steering
Integrated Systems
Joysticks and Control Handles
Microcontrollers and Software
Open Circuit Axial Piston Pumps
Orbital Motors
PLUS+1™ GUIDE
Proportional Valves
Sensors
Steering
Transit Mixer Drives
Local address:
Sauer-Danfoss Inc.
3500 Annapolis Lane North
Minneapolis, MN 55447, USA
Phone: +1 763 509-2000
Fax: +1 763 559-5769
Sauer-Danfoss (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239-6000
Fax: +1 515 239-6618
Sauer-Danfoss ApS
DK-6430 Nordborg, Denmark
Phone: +45 7488 4444
Fax: +45 7488 4400
Sauer-Danfoss GmbH & Co. OHG
Postfach 2460, D-24531 Neumünster
Krokamp 35, D-24539 Neumünster,
Germany
Phone: +49 4321 871-0
Fax: +49 4321 871 122
Sauer-Danfoss-Daikin LTD
Shin-Osaka TERASAKI 3rd Bldg. 6F
1-5-28 Nishimiyahara, Yodogawa-ku
Osaka 532-0004, Japan
Phone: +81 6 6395 6066
Fax: +81 6 6395 8585
www.sauer-danfoss.com
11020635
l
Rev DA
l
November 2012
Members of the Sauer-Danfoss Group:
Comatrol
www.comatrol.com
Schwarzmüller-Inverter
www.schwarzmueller-inverter.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Sauer-Danfoss-Daikin
www.sauer-danfoss-daikin.com
Sauer-Danfoss is a global manufacturer and supplier of high-
quality hydraulic and electronic components. We specialize in
providing state-of-the-art technology and solutions that excel in
the harsh operating conditions of the mobile off-highway market.
Building on our extensive applications expertise, we work closely
with our customers to ensure exceptional performance for a broad
range of off-highway vehicles.
We help OEMs around the world speed up system development,
reduce costs and bring vehicles to market faster.
Sauer-Danfoss—Your Strongest Partner in Mobile Hydraulics.
Go to www.sauer-danfoss.com for further product information.
Wherever off-highway vehicles are at work, so is Sauer-Danfoss.
We offer expert worldwide support for our customers, ensuring the
best possible solutions for outstanding performance. And with an
extensive network of Global Service Partners, we also provide
comprehensive global service for all of our components.
Please contact the Sauer-Danfoss re
p
resentative nearest
y
ou.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20