3 Using the configuration menu DPU 130
14 Machine configuration manual
Setting the overload sensor
The machine's overload sensor detects when you are operating the machine on
hard ground that cannot be further compressed. You can determine how the
machine should react to overload in order to protect it from damage.
1. Press the ON/OFF switch on the machine until the following text appears on
the display:
2. After approx. 2 seconds the following text appears on the display screen and
you can set how the machine is to react in the event of overload.
Push the right control lever on the remote control forward or backward to
select the number.
Value Overload sensor
0 (Factory default setting)
The receiver units briefly flash red.
After more than 10 seconds of overload, an entry is made in
the error memory (error code 13).
The machine can be operated despite overload.
1 The receiver units briefly flash red.
No entry is made in the machine's error memory.
If overloaded, the machine immediately reduces compaction
performance.
2 The receiver units briefly flash red.
After more than 10 seconds of overload, an entry is made in
the error memory (error code 12).
If overloaded for longer than 10 seconds, the engine is
switched off.
3 The receiver units briefly flash red.
No entry is made in the machine's error memory.
If overloaded, the machine immediately switches to slow
operation (engine in idling mode), and reduces compaction
performance.
Setup
Overload sensor
Overload sensor
0