i3 International Ax75RM(v2) Quick start guide

Type
Quick start guide
SAFETY
When installing your Ax75RM(v2) camera be sure to avoid:
excessive heat, such as direct sunlight or heating appliances
contaminants such as dust and smoke
strong magnetic elds
moisture and humidity
areas with mechanical vibrations
uorescent lamps or objects that reect light and unstable light sources
temperatures below -40° C (-40° F) and above 50° C (122° F).
To avoid electrical shock and to preserve the product warranty, DO NOT disassemble the
camera. Refer servicing to qualied personnel only.
POWER SUPPLY
Ensure the supplied voltage meets the power consumption requirements of this camera
before powering the camera on. Incorrect voltage may cause irreparable damage to the
video camera and will effectively void the camera warranty.
Ax75RM(v2) requires DC12V, AC24V or PoE power.
CLEANING
For maximum optical clarity, the camera dome or lens must remain clean. Use a soft,
dry cloth to remove nger prints or dust from the dome cover.
Use a blower to remove dust from the lens.
Clean the body with a soft, dry cloth. If it is very dirty, use a cloth dampened with a
small quantity of neutral detergent, then wipe dry.
Do not use volatile solvents such as alcohol, benzene, or thinners, as they may
damage the surface nishes.
PACKAGE CONTENTS
Ensure that the items received match those listed on the order form and the packing slip.
In addition to this manual and a fully assembled camera, the dome camera packing box
includes:
A. Standard RJ45 Connector x2
B. Round Head Screw (Tapping Type) w/ O-ring x4
C. Plastic Anchor x4
D. Dessicant x1. Use in all outdoor installations.
Attach to the underside of the camera’s inner liner/shroud.
E. 3ft network cable x1
F. Surface Mount template x1
G. Flush Mount template x1
H. Security torx bit x1
I. Long Machine type screws x3
(for Flush Mounting with back box installations)
CAMERA PARTS AND DEFINITIONS
Quick Start Guide
4MP Infrared Outdoor IP Dome Camera w/ Motorized Lens
Ax75RM(v2)
i3-TRNG-CAMS-Ax75RM(v2)-QSG.indd
Rev. 180111
1. Dome bubble housing / Dome cover
2. Screws securing the dome bubble housing to camera module (x3, silver)
3. Lexan bubble
4. Removable back box. Back box comes with six (6) 90% pre-drilled hole dimples.
For surface mounting, complete drilling a minimum of two (2) holes.
5. Camera module / second housing.
6. Tilt bracket with locking screw
7. Inner liner / Shroud. Inner liner is attached to the camera module but can be partially
detached for easier lens adjustment. Attach the desiccant to the inside of the Inner Liner,
without obstructing the lens movement.
8. IR board
9. Pre-installed BNC video output connector for spot monitor output. (Remove back box to
reveal connector)
10. Input/output connectos: Audio In/Out and pre-installed BNC out.
11. 3/4” waterproof rubber plug. For best waterproof performance, use a network cable 5mm
or more in diameter. To maintain IP67 waterproof rating, use sealant on the threads during
installation. If using the side conduit hole, replace the rubber plug with the metal plug from
the side conduit. Rubber plug is not recommended for use in the side conduit hole.
12. 3/4” side conduit hole with metal plug. If using the side conduit hole, remove the metal plug
and use it instead of the rubber plug in the top conduit hole. To maintain IP67 waterproof
rating, use sealant on the threads during installation.
13. Six (6) 90% pre-drilled hole dimples.
14. Reset pin-hole button. Press for 1 second to reboot the camera.
15. Default pin-hole button. Press for 6 seconds to restore camera settings to factory defaults.
16. Service Video Output RCA Port. Connect an analog service monitor for a live image output
preview.
17. Screws attaching camera module to the back box (x3, silver)
18. Screws to engage locking arms (x2, black)
19. Micro SD Card slot for on-camera video storage. (microSD card sold separately)
Lens Direction
GUIDE PATTERN
Scan this QR code or visit www.i3international.
com to view and download the full User Manual
for this camera. Also available for download is the
AnnexxusConfigurationTool or ACT program used to
locate and congure your cameras with your SRX-Pro
software. This program is already installed in SRX-Pro
v3.3.3.69 and higher. Please contact our Technical
Support team if you have any questions or concerns
regarding camera installation or you require software
services or support. Technical support can be reached
by email at: [email protected] or by
phone toll free 1.877.877.7241.
QR Code for Complete
User Manual and ACT
4
5
8
6
7
3
G
H
GUIDE PATTERN
Cut Line
Camera Outline
A
B
C
E
I
F
D
63 mm (2.5”)
63 mm (2.5”)
84 mm (3.3”)
147 mm (5¾”)
68 mm (2.67”)
94 mm (3.7”)
158 mm (6¼”)
1
2
DEFAULT
RESET
MONITOR
RESET
MONITOR
DEFAULT
9
10
11
12
13
14
15
16
17
17
17
18
18
19
DISASSEMBLING THE CAMERA
I/O CONNECTORS
Ax75RM(v2) IP Dome Camera
QUICK START GUIDE
1. Use the provided security
Torx key to loosen three silver
screws securing the dome
bubble housing to camera
module (#6). Do not completely
remove the screws from the
dome bubble. Set the dome
bubble aside.
2. Next, loosen three silver screws
attaching camera to the back
box (#16).
3. Remove camera’s back box and
set aside.
Once the camera’s back box has been removed, the Ax75RM(v2) input/output connectors
will be revealed on the camera’s module, including RJ45 Ethernet/PoE connector, Audio and
Alarm connectors and AC24V/DC12V power port.
1. Audio I/O connectors. Ax75RM(v2) is compatible with i3 Mo-1 microphones. BNC video
output connector is pre-installed in the GND/TV Out ports for spot monitor output.
2. AC 24V / DC 12V Port. Connect either DC 12V or AC 24V power supply.
3. RJ45 Ethernet Connector / PoE. Connect RJ45 network cable for Ethernet/Internet
connectivity. PoE (Power over Ethernet) is supported.
Caution: Do not apply power until the camera is properly and securely mounted.
4. Orange LED. Flashing orange LED indicates data transmission between the camera
and the Internet.
5. Green LED. Solid green LED indicates a current live connection.
FLUSH MOUNTING w/LOCKING ARMS
Note: Based on installation location and surface type, supplied screws and anchors may
not be adequate. Use this installation method for indoor installations only. This method
is suitable for drywall and T-bar installations only. See complete manual for additional
mounting options.
1. Use the Flush Mounting Template to cut
a hole in the mounting surface.
2. Disassemble the camera. Remove
camera’s back box and set aside. It will
not be used in this type of installation.
3. Insert the microSD card into the
microSD slot on the camera module (if
using).
4. Insert the camera into the cut hole in
the surface.
5. Feed all cables through the opening in
the mounting surface and connect to the
camera. Do not apply power until the
installation is complete.
6. Use a Phillips screwdriver to turn two
black-coloured screws on the camera
module clockwise to engage the locking
arms. Tighten the arms securely against the
mounting surface.
7. Adjust the lens angle by rotating and
panning the camera lens base. Lift off
the camera liner for easy lens position
adjustment. Do not over-rotate the camera
lens beyond the stop point to avoid damage
to the camera.
8. Once the desired view is achieved, replace camera liner until it snaps back into place.
9. Replace the camera’s dome bubble on top of the camera module. Use the red dots on
both modules for easy alignment.
10. Use the supplied Torx bit to re-tighten 3 silver screws securing the dome bubble
housing to the camera module.
1
2
3
4 5
1.866.840.0004
www.i3international.com
Canada 780 Birchmount Road, Unit 16,
Scarborough, ON, M1K 5H4
U.S.A 4450 Witmer Industrial Estates Unit 4
Niagara Falls, NY 14305
Rev. 180111
CONNECT CAMERA TO i3 SRX-PRO SERVER
Camera’s default IP address: 192.0.0.16.
Camera’s default Subnet mask address: 255.255.255.0.
Login: i3admin / Password: i3admin
Change your Annexxus camera’s default IP Address:
1. Close SRX-Pro Server software by pressing Alt+Shift+Ctrl+F4.
2. Change the IP address of the onboard NIC (LAN) of your SRX-Pro Server (or
of NIC1 if your SRX-Pro Server has two onboard NIC cards) to 192.0.0.XXX to
match the default IP range of your Annexxus IP camera.
3. Connect your Annexxus camera to i3 SRX-Pro Server (see diagram above).
4. Restart SRX-Pro Server software. Log in and go to the Setup -> IP Camera
tab.
5. Click ACT Config Tool icon. If your NVR does not have
Annexxus Conguration Tool, download and install it from
http://i3international.com/software-downloads website.
6. In ANNEXXUS Conguration Tool window, a list of active network cameras will
be displayed. Select your desired camera in the list.
7. Enter the new IP address and Subnet Mask of the camera in the Device(s)
Communication Update area and click Update. The new camera IP address
must match the
original
range of your SRX-Pro LAN or NIC1 card. E.g. If
your original SRX-Pro Server’s IP address was 192.138.10.122, change your
Annexxus camera’s IP address to 192.138.10.XXX.
Remember:
Annexxus Cameras cannot share an IP address, each camera
requires its own unique IP address.
8. Wait a few moments for a “Success” message in the Result eld.
9. Repeat Steps 7-9 for all detected Annexxus cameras in the ACT.
10. Change the IP address of the NIC back to its original setting (reverse Step 2).
Ensure you can connect to your camera using its new IP Address:
1. Open an Internet browser window and enter the new IP Address you have just
assigned to your Annexxus camera in Step 7.
2. Enter the default camera User Name and default Password in the pop-up login
window.
3. Annexxus camera interface will be displayed in the Internet Explorer window.
You should be able to see the camera image on the screen.
If you do not see the camera image on the screen, call i3 International
technical support team for troubleshooting tips: 1.877.877.7241
Add your Annexxus camera to IP Camera tab in SRX-Pro Server:
1. Ensure that the latest version of GiPi updater is installed on your SRX-Pro
Server. Latest GiPi available from http://i3international.com/software-
downloads.
Note:
SRX-Pro must be closed while GiPi updater is installed. After GiPi
updater installation, start i3 SRX-Pro Server software again.
2. Log In and go to the Setup -> IP Camera tab.
3. Click the Search & Add button to display connected Annexxus cameras.
4. Select the detected camera in the list and click Select.
5. In the
Select IP Camera
window, enter the default camera User Name and
Password, then click Add. Selected camera will be added to the IP Camera
list.
6. Assign the IP camera to the SRX-Pro video channel in the Ch In. column.
7. To enable monotrized lens’ autofocus feature, go to Hardware tab and select
i3 GiPi from the PTZ Camera Type drop-down menu for the corresponding
channel.
Your Annexxus camera is now connected to SRX-Pro Server and is ready to record.
Change resolution and frame rate for the Annexxus camera in the IP Camera tab
menu or via Web Setup.
LAN
Via Gigabit Switch
i3 SRX-Pro Server
Connection Type 1:
(Camera requires AC power):
Connection Type 2:
i3 SRX-Pro Server
i3 INTERNATIONAL INC.
Audio In
GND
GND
GND
Audio Out
N/A
N/A
TV Out
24V
12V
~~
+
Audio In
GND
GND
GND
Audio Out
N/A
N/A
TV Out
Audio In
Audio Out
GND
GND
N/A
N/A
GND
TV Out
Audio In Audio Out
BNC Spot Out
(pre-installed)
  • Page 1 1
  • Page 2 2

i3 International Ax75RM(v2) Quick start guide