Meinberg LANTIME M200 User manual

Type
User manual

Meinberg LANTIME M200 - NTP time server with GPS receiver provides high-precision time base to a TCP/IP network (Stratum-1-Server). It utilizes Network Time Protocol (NTP) to synchronize NTP clients with the reference. As Meinberg LANTIME M200 has an integrated GPS receiver, single-board computer, and power supply, it is ready to operate right out of the box. It features eight push buttons and a display for easy configuration. Remote configuration of the time server is also possible via TELNET, FTP, or a web browser through an integrated web server.

Meinberg LANTIME M200 - NTP time server with GPS receiver provides high-precision time base to a TCP/IP network (Stratum-1-Server). It utilizes Network Time Protocol (NTP) to synchronize NTP clients with the reference. As Meinberg LANTIME M200 has an integrated GPS receiver, single-board computer, and power supply, it is ready to operate right out of the box. It features eight push buttons and a display for easy configuration. Remote configuration of the time server is also possible via TELNET, FTP, or a web browser through an integrated web server.

TECHNICAL REFERENCE
LANTIME M200 GPS
NTP Time Server with GPS Receiver
5th April 2018
Meinberg Radio Clocks GmbH & Co. KG
Table of Contents
1 Imprint 1
2 Safety Instructions for Building-in Equipment 2
2.1 Used Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Global Information LANTIME M200/GPS 4
4 Technical Specifications LANTIME Chassis 5
5 LANTIME M200 - Front connectors 6
6 M200 GPS - Rear connectors 8
6.1 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.2 10/100base-T Ethernet (IEEE 803.2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6.3 USB Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.4 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.5 Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6.6 GPS Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7 Mounting the GPS Antenna 11
7.1 Example: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7.2 Antenna Assembly with Surge Voltage Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7.3 Antenna Short-Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
8 WEEE Compliance 14
9 Declaration of Conformity 15
Date: 5th April 2018 LANTIME M200 GPS
1 Imprint
1 Imprint
Meinberg Funkuhren GmbH & Co. KG
Lange Wand 9, 31812 Bad Pyrmont / Germany
Phone: + 49 (0) 52 81 / 93 09 - 0
Fax: + 49 (0) 52 81 / 93 09 - 230
Internet: https://www.meinbergglobal.com
Date: 2014-10-10
LANTIME M200 GPS Date: 5th April 2018 1
2 Safety Instructions for Building-in Equipment
This building-in equipment has been designed and tested in accordance with the requirements of Standard
IEC60950-1 "Safety of Information Technology Equipment, including Electrical Business Equipment".
During installation of the building-in equipment in an end application (i.e. rack) additional requirements
in accordance with Standard IEC60950-1 have to be taken into account.
The building-in equipment is a class 1 - equipment and must be connected to an earthed outlet
(TN Power System).
The building-in equipment has been evaluated for use in office environment (pollution degree 2) and
may be only used in this environment. For use in rooms with a higher pollution degree more stringent
requirements are applicable.
The building-in equipment may not be opened.
Protection against fire must be assured in the end application.
The ventilation opening may not be covered.
The equipment/building-in equipment was evaluated for use in a maximum ambient temperature of 50
C
(40
C by using Rubidium).
For safe operation the building-in equipment must be protected by max 16 A fuse in the power installation
system.
Disconnection of the equipment from mains is done by pulling the mains plug.
2 Date: 5th April 2018 LANTIME M200 GPS
2 Safety Instructions for Building-in Equipment
2.1 Used Symbols
Nr.
Symbol
Beschreibung / Description
1
IEC 60417-5031
Gleichstrom /
Direct current
2
IEC 60417-5032
Wechselstrom /
Alternating current
3
IEC 60417-5017
Erdungsanschluss /
Earth (ground) Terminal
4
IEC 60417-5019
Schutzleiterklemme /
Protective Conductor Terminal
5
Vorsicht, Risiko eines elektrischen Schlages /
Caution, possibility of electric shock
6
ISO 7000-0434
Vorsicht, Risiko einer Gefahr /
Caution, Danger
7
2012/19/EU
Dieses Produkt fällt unter die B2B Kategorie. Zur Entsorgung
muss es an den Hersteller übergeben werden.
This product is handled as a B2B category product. In order to
secure a WEEE compliant waste disposal it has to be returned
to the manufacturer.
CE label
This device follows the provisions
of the directives 93/68/EEC
LANTIME M200 GPS Date: 5th April 2018 3
3 Global Information LANTIME M200/GPS
The LANTIME (Local Area Network Time Server) provides a high precision time base to a TCP/IP network
(Stratum-1-Server). The NTP (Network Time Protocol) is used to synchronize all NTP clients with the refer-
ence. The several LANTIME variants differ from each other by the time reference and output configuration. A
GPS or GNSS (GPS, GLONASS, Galileo, BeiDou) receiver, GNS-UC (only GPS and Galileo) , a long wave
receiver (like DCF77, MSF or WWVB) or an IRIG time code receiver can be integrated as an internal reference
as well as a combination of these references (hybrid system). External references are also possible.
The LANTIME system is a set of equipment composed of an integrated GPS receiver, a single-board com-
puter and a power supply, all installed in a metal 19 inch modular chassis and ready to operate. A simplified
LINUX operating system is installed on the single-board computers flash disk. Eight push buttons and a display
can be used to configure and monitor the time server.
After the network connection has been establi shed the time server can also be configured and monitored
remotely from a workstation via TELNET or FTP. An integrated web server enables access to the LANTIME by
using an ordinary web browser.
4 Date: 5th April 2018 LANTIME M200 GPS
4 Technical Specifications LANTIME Chassis
4 Technical Specifications LANTIME Chassis
Protection
Rating: IP20
Power
Consumption: Base configuration: 30 W
(max. 50 W - depending on the integrated module options)
Ambient
Temperature: 0 ... 50
C
Storage Temperature: -20 ... 70
C
Humidity: max. 85% (non-condensing) @ 30
C
LANTIME M200 GPS Date: 5th April 2018 5
5 LANTIME M200 - Front connectors
1
2
3
GPS: NORMAL OPERATION
NTP: Offset PPS: -4µs
UTC 12: 00 : 00
Mon , dd.mm.yyyy
LANTIME M200
OK
ESC
F1
F2
Time Service
Ref. Time
Network
Alarm
1. The main menu is displayed after switching on the
device and having completed the initialization phase.
In the main menu the most important status informa-
tion are displayed. In the top line of the display the
operating mode of the reference clock / reference time
is shown. Instead of "GPS: NORMAL OPERATION"
the messages, "GPS: COLD BOOT", "GPS: WARM
BOOT" or "GPS: UPDATE ALMANAC" can appear.
In case the antenna connection is interrupted, the fol-
lowing message is shown: "GPS: ANTENNA FAULTY".
GPS: NORMAL OPERATION
NTP: Offset PPS: -4µs
UTC 12: 00 : 00
Mon , dd.mm.yyyy
2. By using the 4 arrows and the "ESC", "F1" and
"F2" buttons of the keypad you can navigate through
each menu in the display. You can always return to
the main menu by pressing the "ESC" button several
times.
OK
ESC
F1
F2
6 Date: 5th April 2018 LANTIME M200 GPS
5 LANTIME M200 - Front connectors
3.
"Ref. Time"
green: the reference clock (e.g. build-in GPS) provides a valid time
red: the reference clock does not provide a valid time
"Time Service"
green: NTP is synchronized to the
reference clock, e.g. GPS
red: NTP is not synchronized or
switched to the "local clock"
"Network"
green: all monitored network interfaces
are connected ("Link up")
red: at least one of the monitored
network interfaces is faulty
"Alarm"
off: no error
red: general error
Time Service
Ref. Time
Network
Alarm
LANTIME M200 GPS Date: 5th April 2018 7
6 M200 GPS - Rear connectors
100-240V AC
50/60Hz
GPS
Antenna
O
I
1
6
2
3
4
CONSOLE
38400/8N1
A
N
T
R
0
5
6.1 Power Connector
Input Voltage Range: 100-240 V AC, 50 - 60Hz
Input Current: 0.65 Amax
Input Fuse: UL/IEC127, 250 V AC S 3.15 A
Connector: input IEC320 AC inlet
O
I
100-240 V , 50-60 Hz
6.2 10/100base-T Ethernet (IEEE 803.2)
Link Speed: 10/100 MBit
Connector Type: 8P8C (RJ45)
Cable: CAT 5.0
Duplex Modes: Half/Full/Autonegotiaton
0
8 Date: 5th April 2018 LANTIME M200 GPS
6 M200 GPS - Rear connectors
6.3 USB Port
All devices of the LANTIME M-Series dispose a USB
interface, which can be used to plug in a USB Stick.
The USB Stick can be deployed for the following tasks:
to lock the keys on the LC-Display, to prevent
unauthorized access
to save the LANTIME configuration
to transfer the configuration between several
LANTIMES
to save log files
USB
6.4 Terminal
To connect a serial terminal (according to the device
model), use the RJ45 connector of the LAN-CPU. Via
the serial terminal connection it is possible to con-
figure parameters with a command line interface. You
have to use a CAB-CONSOLE-RJ45 cable to establish
a connection to your PC or Laptop computer. You can
use e.g. the standard Hyperterminal program shipped
with your Windows operating system. Configure your
terminal program with 38400 Baud, 8 Databits, no
parity and 1 Stopbit. The terminal emulation have to
set to VT100. After connecting to the timeserver there
will be displayed the login message (press RETURN
for first connection:
(default user: root; password: timeserver).
CONSOLE
38400 / 8N1
DCD_IN
RXD_IN
TXD_OUT
GND
3
4 + 5
6
7
6.5 Status LEDs
3.
"Ref. Time"
green: the reference clock (e.g. build-in GPS)
provides a valid time
red: the reference clock does not provide a valid time
"Time Service"
green: NTP is synchronized to the
reference clock, e.g. GPS
red: NTP is not synchronized or
switched to the "local clock"
"Network"
green: all monitored network interfaces
are connected ("Link up")
red: at least one of the monitored
network interfaces is faulty
"Alarm"
off: no error
red: general error
A
N
T
R
(Alarm)
(Network)
(Time Service)
(Ref. Time)
LANTIME M200 GPS Date: 5th April 2018 9
6.6 GPS Antenna
Cable: shielded coax
Cable Length: max. 300m to RG58,
max. 700m to RG213
Connector: BNC female or N-type female
Input GPS: Antenna circuit
1000 V DC insulated
Local Oscillator
to Converter Frequency: 10 MHz
1
First IF Frequency: 35.4 MHz
1
1) these frequencies are transfered via the antenna cable.
Power Requirements: 12V ... 18V, 100mA (via antenna cable)
GPS
Antenna
GPS
Antenna
BNC N-Norm
N-type
10 Date: 5th April 2018 LANTIME M200 GPS
7 Mounting the GPS Antenna
7 Mounting the GPS Antenna
The GPS satellites are not stationary, but circle round the globe with a period of about 12 hours. They can only
be received if no building is in the line-of-sight from the antenna to the satellite, so the antenna/downconverter
unit must be installed in a location that has as clear a view of the sky as possible. The best reception is
achieved when the antenna has a free view of 8
angular elevation above the horizon. If this is not possible, the
antenna should be installed with the clearest free view to the equator, because the satellite orbits are located
between latitudes 55
North and 55
South. If this is not possible, you may experience difficulty receiving the
four satellites necessary to complete the receivers position solution.
The antenna/converter unit can be mounted on a wall, or on a pole up to 60 mm in diameter. A 50 cm
plastic tube, two wall-mount brackets, and clamps for pole mounting are included. A standard RG58 coaxial
cable should be used to connect the antenna/downconverter unit to the receiver. The maximum length of cable
between antenna and receiver depends on the attenuation factor of the coaxial cable.
Up to four GPS receivers can be run with one antenna/downconverter unit by using an optional antenna
splitter. The total length of an antenna line from antenna to receiver must not be longer than the max. length
shown in the table below. The position of the splitter in the antenna line does not matter.
The optional delivered MBG S-PRO protection kit can also be used for outdoor installation (degree of protec-
tion: IP55). However, we recommend an indoor installation, as close as possible to the wall where the antenna
cable is entering, to minimize the risk of overvoltage damage, for example by lightning.
7.1 Example:
Type of cable diameter Ø Attenuation at 100MHz max lenght.
[mm] [dB]/100m [m]
RG58/CU 5mm 17 300 (1)
RG213 10.5mm 7 700 (1)
(1)This specifications are made for antenna/converter units produced after January, 2005
The values are typically ones; the exact ones are to find out from the data sheet of the used cable
LANTIME M200 GPS Date: 5th April 2018 11
7.2 Antenna Assembly with Surge Voltage Protection
Optional a surge voltage protector for coaxial lines is available. The shield has to be connected to earth as
short as possible by using the included mounting bracket. Normally you connect the antenna converter directly
with the antenna cable to the system.
12 Date: 5th April 2018 LANTIME M200 GPS
7 Mounting the GPS Antenna
7.3 Antenna Short-Circuit
(systems with front display only)
In case of an antenna line short-circuit the following message appears in the display:
ANTENNA
SHORT-CIRCUIT
DISCONNECT POWER
! ! !
If this message appears the clock has to be disconnected from the mains and the defect eliminated. After that
the clock can be powered-up again. The antenna supply voltage must be 15VDC .
LANTIME M200 GPS Date: 5th April 2018 13
8 WEEE Compliance
Compliance with EU Directive 2011/65/EC (RoHS)
We hereby declare that this product i s conform to
the European Directive 2011/65/EC, “Restrictions of
Hazardous Substances in Electrical and Electronic
Equipment. We ensure that electrical and electronic
products sold in the EU do not contain lead, cad-
mium, mercury, hexavalent chromium, polybrominated
biphenyls (PBBs), and polybrominated diphenyl ethers
(PBDEs) above the legal threshold.
WEEE status of the product
This product is handled as a B2B (Business to Busi-
ness) category product. In order to secure a WEEE
compliant waste disposal it has to be returned to the
manufacturer. Any transportation expenses for return-
ing this product (at its end of life) have to be incurred
by the end user, whereas Meinberg will bear the costs
for the waste disposal itself.
14 Date: 5th April 2018 LANTIME M200 GPS
9 Declaration of Conformity
9 Declaration of Conformity
Konformitätserklärung
Doc ID: LANTIME M200/GPS-2014-10-10
Hersteller Meinberg Funkuhren GmbH & Co. KG
Manufacturer Lange Wand 9, D-31812 Bad Pyrmont
erklärt in alleiniger Verantwortung, dass das Produkt,
declares under its sole responsibility, that the product
Produktbezeichnung LANTIME M200/GPS
Product Designation
auf das sich diese Erklärung bezieht, mit den folgenden Normen übereinstimmt
to which this declaration relates is in conformity with the following standards
EN55032:2012, Class B Limits and methods of measurement of radio interference characteristics
of information technology equipment
EN55024:2010 Limits and methods of measurement of Immunity characteristics of information
technology equipment
EN 60950-1:2006 Safety of information technology equipment
(A11:2009 + A1:2010 + A12:2011 + AC:2011 + A2:2013)
EN 50581:2012 Technical documentation for the assessment of electrical and electronic products
with respect to the restriction of hazardous substances
gemäß den Richtlinien 2014/30/EU (Elektromagnetische Verträglichkeit), 2014/35/EU (Niederspannungsrichtlinie),
2011/65/EU (Beschränkung der Verwendung bestimmter gefährlicher Stoffe) und 93/68/EWG (CE Kennzeichnung)
sowie deren Ergänzungen.
following the provisions of the directives 2014/30/EU (electromagnetic compatibility), 2014/35/EU (low voltage
directive), 2011/65/EU (restriction of the use of certain hazardous substances) and 93/68/EEC (CE marking) and
its amendments.
Bad Pyrmont, 2014-10-10
LANTIME M200 GPS Date: 5th April 2018 15
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Meinberg LANTIME M200 User manual

Type
User manual

Meinberg LANTIME M200 - NTP time server with GPS receiver provides high-precision time base to a TCP/IP network (Stratum-1-Server). It utilizes Network Time Protocol (NTP) to synchronize NTP clients with the reference. As Meinberg LANTIME M200 has an integrated GPS receiver, single-board computer, and power supply, it is ready to operate right out of the box. It features eight push buttons and a display for easy configuration. Remote configuration of the time server is also possible via TELNET, FTP, or a web browser through an integrated web server.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI