CCHHAANNNNEELLPPLLUUSS
HH1111XXLL -- HH1177XXLL SSEERRIIEESS22
IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS
INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WWAARRNNIINNGG :: IISSOOLLAATTEE MMAAIINNSS SSUUPPPPLLYY BBEEFFOORREE CCOOMMMMEENNCCIINNGG IINNSSTTAALLLLAATTIIOONN
FFIITTTTIINNGG TTHHEE BBAACCKKPPLLAATTEE
Once the Backplate has been removed from the
packaging please ensure the timeswitch is
re-sealed to prevent damage from dust, debris
etc.
The Backplate should be fitted with the wiring
terminals located at the top and in a position
which allows the relevant clearances around
the timeswitch. (See diagram)
DDIIRREECCTT WWAALLLL MMOOUUNNTTIINNGG
Offer the plate to the wall in the position where the timeswitch is to be mounted, remembering that
the Backplate fits to the right hand end of the timeswitch.
Mark the fixing positions through the slots in the Backplate (Fixing centres 60.3mm), drill and plug the
wall, then secure the plate in position. The slots in the Backplate will compensate for any
misalignment of the fixings.
WWIIRRIINNGG BBOOXX MMOOUUNNTTIINNGG
The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662,
using two M3.5 screws.
ChannelPlus series 2 timeswitches are suitable for mounting on a flat surface only, they must not be
positioned on a surface mounted wall box or on unearthed metal surfaces.
EELLEECCTTRRIICCAALL CCOONNNNEECCTTIIOONNSS
All necessary electrical connections should now be made. Flush wiring can enter from the rear through
the aperture in the Backplate. Surface wiring can only enter from beneath the timeswitch and must be
securely clamped.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring.
The recommended cable sizes are 1.0mm
2
or 1.5mm
2
.
Page 1Page 4
LEAFLET No P82730
ISSUE 1
SSPPEECCIIFFIICCAATTIIOONN HH1111XXLL -- HH1177XXLL SSEERRIIEESS 22
CCoonnttaacctt ttyyppee::
Micro dis-connection(Voltage free)
CCoonnttaacctt rraattiinngg::
3(1)Amps 230-240V AC
PPoowweerr ssuuppppllyy::
230V AC 50Hz
OOppeerraattiinngg TTeemmppeerraattuurree rraannggee::
0
o
C to 40
o
C
DDoouubbllee iinnssuullaatteedd..
DDiirrtt pprrootteeccttiioonn::
Normal situations.
EEnncclloossuurree pprrootteeccttiioonn::
IP30
PPuurrppoossee ooff ccoonnttrrooll::
Electronic timeswitch
IInnddeeppeennddeennttllyy mmoouunntteedd ccoonnttrrooll ffoorr ssuurrffaaccee mmoouunnttiinngg..
OOppeerraattiinngg ttiimmee lliimmiittaattiioonn::
Continuous
BBaatttteerryy TTyyppee::
Lithium
CCaassee mmaatteerriiaall::
Thermoplastic, flame retardant
DDiimmeennssiioonnss::
163mm x 101mm x 37mm
DDiissppllaayy::
Fully graphical LCD, back-lit
CClloocckk::
24hour /12 hour AM/PM
DDiissppllaayy ttiimmee aaddjjuussttmmeenntt::
1 Minute steps
SSwwiittcchheedd ttiimmee aaddjjuussttmmeenntt::
10 Minute steps
PPrrooggrraammmmee sseelleeccttiioonn::
Auto, On all day, On constant, Off, Holiday
OOppeerraattiinngg ppeerriiooddss ppeerr ddaayy::
Three per channel -
(Separate daily programmes for H17XL)
OOvveerrrriiddee::
Boost, 1 or 2 Hours
Extension to ON period, 1Hr or 2Hr
Instant Advance
BBaacckkppllaattee::
9 Pin terminal connection
Horstmann Controls Limited
Bristol
BS4 1UP
t:0117 9788 773 - f:0117 9788 701
Website: www.horstmann.co.uk
HHoorrssttmmaannnn CChhaannnneellPPlluuss XXLL SSeerriieess 22 -- SSiinnggllee CChhaannnneell TTiimmeesswwiittcchh..
Offers up to
three programmed operating periods per day, with independent Boost and
Advance control. This model has a fully graphical, back-lit display combined
with simple menu driven programming.
It is a direct replacement for existing Horstmann ChannelPlus H11XL and
H17XL timeswitches, utilising existing wiring and backplate connections.
GGEENNEERRAALL IINNFFOORRMMAATTIIOONN
BBAATTTTEERRYY
The programmer is fitted with a non-rechargeable, non-serviceable long life battery, which will
maintain the programmed time settings with the mains supply disconnected.
THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.
During power interruptions the display will be blank.
Before handing over the installation to the user, always ensure that the system responds correctly on all
control programmes and that other electrically operated equipment and controls are correctly adjusted.
EEXXPPLLAAIINN HHOOWW TTOO OOPPEERRAATTEE TTHHEE CCOONNTTRROOLLSS AANNDD HHAANNDD OOVVEERR TTHHEE UUSSEERRSS OOPPEERRAATTIINNGG IINNSSTTRRUUCCTTIIOONNSS TTOO TTHHEE UUSSEERR..
Lower the front flap of the unit. On right hand Channel
press the ADVANCE(Enter) and SELECT(Blue) buttons
together then release the buttons and the programmer
will return to the preset factory settings.
RREESSEETT PPRROOCCEEDDUURREE
Electronic equipment can in some circumstances be affected by electrical interference. If the display
becomes frozen or scrambled; or if you wish to revert back to the default settings please use the
following procedure.
RREESSEETTTTIINNGG TTHHEE CCHHAANNNNEELLPPLLUUSS XXLL SSEERRIIEESS 22
PPLLEEAASSEE NNOOTTEE;;
Using this procedure will restore the ChannelPlus to the original factory
programme settings, the time setting will also default to
11sstt JJaannuuaarryy 22000055
- See Adjusting
Time and Date on page 3 of the user guide.
ADVANCE
SELECT
BOOST
RESET