  • Hello! I am an AI chatbot trained to assist you with the Dometic 3313107.016 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
REVISION A
Form No. 3313172.011 01/17
©2017 Dometic Corporation
LaGrange, IN 46761
Important: Before making the thermostat replace-
ment determine which unit is installed (air conditioner
or heat pump). Follow appropriate instructions below.
A. Heat Pump (3100292.139 Air Distribution Box)
1. Mount the thermostat 3311951.010 to the front
cover with screws as shown in FIG. 1.
2. Connect the Grey or White with Grey stripe
wire to pin 4 (L).
3. Connect the Blue with Black stripe from 9 pin
connector Or white with Black stripe wire to
pin 3 (C).
4. Connect the Blue or Blue with White stripe
from switch wire to pin 6 (H).
5. Verify wiring is correct as compared to FIG. 1 and
reinstall the covers.
6. Turn on 220 VAC power supply and check opera-
tion.
GENERAL INSTRUCTIONS
The thermostat kit is designed specically for the
3100292.121 and 3100292.139 mechanical air distribu-
tion box.
Important: Keep these instructions with air condition-
er owners manual for future reference.
The kit consists of:
(1) Thermostat
(1) Instruction Sheet
INSTALLATION INSTRUCTIONS
These instructions must be read and understood
before installation of this kit. This kit must be in-
stalled by a Dometic Corporation Service Cen-
ter or a qualied service technician. Modication
of this product can be extremely hazardous and
could result in personal injury or property damage.
3313107.016 THERMOSTAT KIT
REPLACEMENT INSTRUCTIONS
SERVICE OFFICE
Dometic Corporation
For Information Contact:
www.eDometic.com
Read and follow all safety information and
instructions to avoid personal injury.
Disconnect all 220 VAC power supplies. Fail-
ure to obey this instruction may create a
shock hazard.
SAFETY INSTRUCTIONS
This manual has safety information and instruc-
tions to help users eliminate or reduce the risk
of accidents and injuries.
RECOGNIZE SAFETY INFORMATION
This is the safety alert symbol. It is used to alert
you to personal injury hazards. Obey all safety
messages that follow this symbol to avoid pos-
sible injury or death.
UNDERSTAND SIGNAL WORDS
A signal word, when used with the safety alert
symbol, will identify a safety hazard and its level
of risk for personal injury. A signal word, without
the safety alert symbol, will be used for property
damage messages only.
WARNING indicates a hazard-
ous situation which, if not avoided, could result
in death or serious injury.
CAUTION, used with the safe-
ty alert symbol, indicates a hazardous situation
which, if not avoided, could result in minor or
moderate injury.
NOTICE is used to address
practices not related to personal injury.
Read and follow all safety information and
instructions to avoid personal injury.
2
Alternate Thermostat 313620.004 Re-
placement Instructions
Important: Before making the thermostat replacement deter-
mine which unit is installed (air conditioner or heat pump). Follow
appropriate instructions below.
A. Air Conditioner (3100292.121 Air Distribution Box)
1. Mount thermostat in direction shown in FIG. 1.
2. Rewire new thermostat as shown in FIG. 1.
3. Mark thermostat as described in FIG. 3.
B. Heat Pump (3100292.139 Air Distribution Box)
1. Mount thermostat in direction shown in FIG. 2.
2. Rewire new thermostat as shown in FIG. 2.
3. Mark thermostat as described in FIG. 3.
C. Turn on 220 VAC power supply and check operation.
3100292.121 Air Distribution Box Used
With Model 3253.XXX Air Conditioner
FIG. 1
Grey
White Or
White With
Black Stripe
To Neutral Field
Connection
3100292.139 Air Distribution Box Used
With Model 3254.XXX Heat Pump
FIG. 2
Blue Or Blue With White
Stripe From Switch
Grey Or White With Grey Stripe
Blue With Black
Marker From
9 Pin Connector
Or White With
Black Stripe
If ADB Wiring Decal Is Numbered 2, 3, & 4 Write Numbers 3 & 4
Here. If Numbered Different Than Shown, Do Not Write Numbers
On The Part And Black Out Any Numbers That Are Hand Written
On It.
FIG. 3
Blue Or White With
Brown Strip
FIG. 1
3100292.139 Air Distribution Box Used
With Model 3254.XXX Heat Pump
(3) Blue With Black Stripe From
9 Pin Connector Or White With
Black Strip (3/C)
B. Air Conditioner (3100292.121 Air Distribution
Box)
1. Mount the thermostat (3311951.010) to the front
cover with screws as shown in FIG. 2.
2. Connect the White or White with Black stripe
wire to pin 4(L).
3. Connect the Blue or White with Brown stripe
and Black (to neutral wire to pin 3 (C).
4. Connect the Grey wire to pin 6 (H).
5. Verify wiring is correct as compared to FIG. 2 and
reinstall the covers.
6. Turn on 220 VAC power supply and check opera-
tion.
(4) Blue Or Blue With
White Stripe From
Switch (6/H)
FIG. 2
3100292.121 Air Distribution Box Used
With Model 3253.XXX Air Conditioner
(2) Grey Or White With Grey Stripe (4/L)
(2) White Or White With
Black Stripe (4/L)
(3) Blue Or White With Brown Stripe And
Black To Neutral (Field Connection) (3/C)
(4) Grey (6/H)
/