MS-CRD-FIXTURE Series

Swagelok MS-CRD-FIXTURE Series Operating instructions

  • Hello! I'm a chat assistant ready to help you with your Series 5, 10, and 20 Weld Head Tube Fixture Block. I have reviewed the user manual, which contains instructions for attaching the centering gauge and adjusting the alignment. I can answer questions about these procedures or any other topics covered in the documentation.
  • What size screws are used to attach the lanyard and centering gauge?
    What is the first step in alignment adjustment?
    What do you need to insert to align the device?
Series 5, 10, and 20 Weld Head Tube Fixture Block
Attaching Centering Gauge to Plenum
1. Attach a
screw
(#4-40 UNC), a lock washer, and
one end of the
lanyard
to the side of the
plenum
2. Use a
screw
(#4-40 UNC) and lock washer to
attach the
centering gauge
to the other end of
the
lanyard
.
Fixture side plates
Plenum
Plenum
Lanyard
Screw
Centering
Centering
gauge
Collets
Cap
Cap
screws
Cap
Cap
Cap
Cap
Cap
Cap
Latch
Series 5, 10, and 20 Weld Head Tube Fixture Block
Alignment Adjustment Instructions
1. Loosen the four
cap screws
on the
xture side
plate
pointed to by the arrows on the
plenum
.
2. Place a minimum length of tubing in the
collets
so it rests across both side plates.
Swagelok − TM Swagelok Company July 2005, R0
© 2005 Swagelok Company MS-CRD-FIXTURE
Weld Head Series
Minimum Tubing Length,
in. (mm)
Series 5
1.50 (38.1)
Series 10
2.00 (50.8)
Series 20
3.00 (76.2)
3. Lock down the stationary
xture side plate
and
then the loosened
xture side plate
using the
latches
at the top of the fi xture side plates.
4. Tighten the four
cap screws
loosened in step 1.
5. Release the latching mechanism, and remove the