NIGHTJAR SERIES
06
3.7 RESET AFTER SHUTDOWN
Whenever the power supply latches into shutdown state due to fault condition on
its output, the power supply will return to normal operation only after the fault has
been removed and the PS_ON# has been pulled low again. If the power supply
latches into shutdown state due to fault condition on 5Vsb, the power supply will
return to normal operation only after the fault has been removed and the power
switch (power cord) has been cycled off/on (plugged out/in) with A MINIMUM
OFF TIME OF 3 SECONDS.
4.0 ENVIRONMENT
4.1 OPERATING
AMBIENT OPERATION TEMPERATURE: 0 to 45 . (The rated power will
derate from 100% to 80% from 40 to 45 Linearly)
AMBIENT OPERATION RELATIVE HUMIDITY: To 85% relative humidity
(non-condensing)
4.2 SHIPPING / STORAGE
AMBIENT STORAGE TEMPERATURE:-40 to 85
AMBIENT STORAGE RELATIVE HUMIDITY: To 95% relative humidity
(non-condensing)
5.0 MTBF
Over 100,000 hours at 25 .
6.0 EMC
Comply to EN55022: 2006 +A1: 2007 Class B, EN55024: 1998 +A1: 2001 +A2:
2003, EN61000-3-2: 2006 +A1: 2009 +A2: 2009 Class A/D, EN61000-3-3: 2008,
FCC Part 15, Subpart B, Class B, CISPR 22: 2008, ICES-003: 2004, ANSI C63.4
(2003),AS/NZS CISPR 22:2009.
7.0 SAFETY
Confirm to IEC 60950-1: 2009, EN 60950-1/A12: 2011, UL 60950-1, 2nd Edition &
CSA C22.2 No. 60950-1-07, 2nd Edition.
8.0 MECHANICAL
Dimension: 150 mm (W) × 86 mm (H) × 160mm (D)