Rio Beauty Scanning Laser X60 Owner's manual

Category
Light depilation
Type
Owner's manual

This manual is also suitable for

LAHC5
CLASS 1 PRODUCT
CONTAINING
CLASS 3B LASER
808nm
wavelength
Wearing laser
safety goggles is
unnecessary as
the product has
been designed
with inbuilt safety
features.
PATENTS PENDING
This product MUST be used responsibly.
Please read these Instructions carefully
before use.
Refer to your Information Guide for:
• WARNINGS
• SECURITYBUTTONSEQUENCE
• HOWDOLASERSWORK?
• SUITABLESKINTYPES
• PATCHTEST
• HAIRGROWTHCYCLE
• WHYISASERIESOFTREATMENTS
REQUIRED?
• YOURQUESTIONSANSWERED
• TROUBLESHOOTING
SALON LASER
SCANNING HAIR REMOVER x60
WARNINGS
• Readallinstructionsthoroughlyandretainforfuturereference.
• NotsuitableforAfro-Caribbean, black skincomplexionsor forGreyHair.
See“SuitableSkinTypes”inInformationGuide.
• Laserhairremovalshouldnotcausediscomfort,youmayfeelindividualhairs
beingtreated,whichislikeamildpinprick,andaslightwarmingofthearea.
Ifyoufeelanydiscomfortorsorenessthesettingmaybetoohigh.
• Inbuiltsafetyfeaturesprotecttheeyebeingexposedtothelaser,however,
neveraimtheWandatorneareyes.
• DoNOTusenearflammablematerials.
• Keeptheproductoutofreachofchildrenandpets.
• ReflectionHazard:Pleaseremovealljewelleryinthevicinityofthetreatment
areabeforeuse.
• Whennotinuse,storethekeyresponsiblyinasafeplaceawayfromchildren.
• Donottreatthesamehairrepeatedlyinanyonesession.
• Donotuseafterdrinkingalcoholorifyouarefeelingunwellorfatigued.
• Donottreatthefollowingareas:tattoos,permanentmake-up,pimples,warts,
haironblackspotsormoles,darkfreckles,skindisease,birthmarks,burns,
lips,nipples,genitaloranalareas,eczema,eyelashes,eyebrows,nearthe
eyes,nasalorearhair.
• Thisisasensitivelaserscanningproduct.Careshouldbetakentoavoid
damagetothemechanismintheWand.
• Thisapplianceisnotintendedforusebypersonswithreducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
they have been given supervision or instruction concerning use of the
appliancebyapersonresponsiblefortheirsafety.
PRECAUTIONS
• DoNOTdismantleorrepair.Ifyouhaveanyproblemsusingtheproduct,
contactourCustomerCareDepartment.
• Misuseoftheunitcancauseharm.
• DoNOToverrideanysafetyfeaturesoropentheunitorwand.
• OnlyusethisproductwiththeMainsAdaptersupplied.
• KeepWandawayfromstrongelectromagneticfieldsandmagnetsduringuse.
PATCHTEST
IMPORTANT:24hoursbeforetreatmentitisveryimportanttodoapatchtest.
Thepatchtestwillconfirmthemaximumpowerlevelforyourskintype.Eacharea
tobetreatedmustbecheckedasskincolourcanvary.Pleaserefertothe‘PATCH
TEST’sectionintheInformationGuideandontheDVDforinstructions.
Aslightrednessmayoccur,butnotalways,withinanhouroftreatment.This
localisedrednessiscausedbythedestructionofthehairfolliclesandisquite
normal.However,ifanyrednessremainsafter24hoursthiswouldindicatethe
powerlevelselectedwastoohighforyourskintype.
GETTINGSTARTED
Please ensure you read the Information Guide and understand the
‘Warnings’ and ‘Product Safety’ sections before proceeding.
• Shavetheareatobetreated.Thisensuresthatthelasergoesdirectly
tothehairrootandavoidshairburningonthesurface.
• Removealljewelleryinthevicinityofthetreatmentarea.
• Pleaseensureyouhavepatchtestedtheareatobetreated24hours
prior to treatment.
STEP 1
ConnectMainsAdapterintotheDCPowerSocketat
thebackoftheunitandplugintotheMains.
STEP2
Unlock with Key to turn on. The light around the
Keyswitchwillflashgreen.
STEP 3
Enterthe“SECURITYBUTTONSEQUENCE”.
You will find the Security Button Sequence in the
Information Guide.
ThegreenlightaroundtheKeyswitchwillfullyilluminate.
Thelightsaroundthex60SCAN,x20SCANandSINGLE
buttonswillflashbluereadyforselection.Thebottom
PowerLevelIndicatorlightwillilluminate.
STEP4
Usethe+/-buttonstoselectthecorrectpowerlevel
foryourskintype.Refertothe‘PatchTest’sectionof
theInformationGuideforskintypes.
Each time the power setting is adjusted, you will
need to reselect x60 SCAN, x20 SCAN or SINGLE
modetocontinue.
Note:Ifnobuttonsarepressedafter20minutestheUnitwillenterenergy
savingmode.The orangelightwill flashandpower level1 will remainon.
TorestartturnkeyoffandbackonagainandstartatStep3.
ADDITIONALINFORMATION
STEP 8
Turn the Keyswitch anticlockwise to lock the unit.
RemovetheKeytoasafeplaceawayfromchildren.
Note: Ifyouexperienceunexpectedbehaviourofthisproductthenitispossible
someexternalelectromagneticinterferenceisresponsiblee.g.electricmotors/
loudspeakersetc.Youshouldremovethissourceandrestarttheproductto
restorefulloperation.Atnotimewillthelaserfireunintentionally.
‘SINGLE’HAIRTREATMENT
Youcanopttotreatsinglehairsusing
theSINGLEmode.
Press the ‘SINGLE’ button once.
TheSINGLEbuttonwillilluminateblue.
The orange light on the Wand
willilluminate.
FollowthesameprocedureforSCANtreatmentfromStep6,butthistime
pressing the SINGLE button.
InSINGLEmode,thebluelightaroundtheSINGLE
buttonwillflash.
Referto‘TreatmentArea’section,SINGLEmode.
SECURITY
BUTTON
SEQUENCE”
TREATMENTAREA
Asaguidetothetreatmentarea,asmallindentationmarkwillbeleftby
pressingtheWanddownontheskin.Inx60SCANmode,overlapping
theindentationmarkslightlywhenmovingtheWandineachdirectionwill
ensureeffectivecoverage.Inx20SCANmode,overlaptheindentation
markbyhalf.
SCANmodessequentiallytargetsinglehairsineachtreatment.
SINGLEmodeisfortreatingindividualhairs.Thetreatmentareaisinthe
centreoftheindentationguideandmeasures1mmx1mm.
‘SCAN’HAIRTREATMENT
STEP 5
Press the x60 SCAN button once. The
blue light around the button will fully
illuminate.Theorangelightonthewand
willilluminate.
Alternatively,pressthex20SCANbuttononce.
STEP6
Placethewandontheskinovertheareayouwishtotreat,
ensuringtheTouchPinsareincontactwiththeskin.
TheorangelightwillturnOFFandthewhite‘ready’light
willturnON.
ThebluelightsaroundtheSCANbuttonwillrotateto
indicatetreatmentisreadytostart.
STEP 7
Press and HOLD the Laser Button on the top of the
wandtostartlasertreatment.
The white light will flash on and off to indicate laser
treatmentisinprogressandtheunitwillbeeprepeatedly
(thiscanbemuted).Youwillnotbeabletoseethelaser.
You may feel individual hairs being treated, whichis
likeamildpinprick,andaslightwarmingofthearea
beingtreated.
Whenthelasertreatmentceases,theorangelightwill
comebackon.Youcannowmoveontothenextareaof
hairstobetreated.
Whenmovingthewandtothenextareaofhairstobe
treatedtheTouchPinsmustberemovedbrieflyfrom
theskin.
Refertoscanmodesin‘treatmentarea’section.
IMPORTANTNOTES - please read carefully
• DoNOTmovethewandduringtreatment.Youmaynoticethewandbecomes
warmduringusethisisquitenormal.
• IfcontactislostbetweentheTouchPinsandskinduringtreatment,thewand’s
orangelightwillcomeon.Treatmentwillresumewhencontactismadeagain.
• Foryoursafety,ifthewandisnotpositionedcorrectlyontheskinsurfacefor
treatment,thewhiteandorangelightswillflashalternatelyandoperationof
thelaserwillbedisabled.
• Sometimesyou cansmell faint burningor even seea very, smallline of
smokeasthehairistreated.
• Successfullytreatedhairsdonotalwaysfalloutimmediately,butareshed
over time as they are released from the hair follicle, light rubbing can
encouragethis.
• Youmayfeela‘pinprick’sensationduringtreatment.Anylocalisedrednessafter
treatmentiscausedbythedestructionofthehairfolliclesandisquitenormal.If
anyrednessremainsafter24hoursthiswouldindicatethepowerlevelselected
wastoohighforyourskintype.Pleaserefertothe‘PatchTest’sectioninthe
InformationGuide.Anylongerlastingrednesswillalsodisappear.
LASERHAIRTREATMENT
1
2
5
8
7
3
4
PresstheMUTEbuttononthebackoftheUnittoturn
offtheBeepnoises.Pressagaintoturnbackon.
Note: Thisdoesn’tturnoffwarningbleeps.
resettingafter‘lockout’
If you experience a ‘lockout’ as indicated by
repeatedflashingofanyofthebluepowerlights,
simplyresetbyturningtheunitoffusingthekey,
waiting5secondsandturningtheunitonagain.
cleaninglaseraperture
Periodically check whether there are any smoke
deposits on the Laser Aperture. A build up of
depositswillaffecttheefficiencyofthelaser.Ifyou
noticeanydeposits,switchtheunitOFFandunplug
themainsadapter.Thensimplycleanwithalintfree
clothorcottonbud,ensuringnofibresareleftinthe
LaserAperture.
x60 SCANmode
x20SCANmode
SINGLEmode
Rio,Dezac,SalonLaserScanningHairRemoverx60andLaserSafeTechnologyaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2011anufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
Overlapbyathird
Overlapbyhalf
treatmentarea
indentationmark
treatmentarea
indentationmark
treatmentarea
indentationmark
1-IN-LAHC5-UK/1.2
instructions
b
e
f
g
h
i
k
j
l
m
c
a
d
n
o
p
q
r
s
COMPONENTS
a. Mains Adapter
b. Keys
c. DC Power Socket
d. Mute Button
e. Keyswitch
f. Power Level Indicator
g. Power Increase Button (+)
h. Power Decrease Button (-)
i. x60 SCAN button
j. x20 SCAN button
k. SINGLE button
l. Hand-held Wand
m. Laser Button
n. Orange Light
o. White Light
p. Touch Pins
q. Laser Aperture
r. Indentation Guide
s. Front Face
laseraperture
6
  • Page 1 1

Rio Beauty Scanning Laser X60 Owner's manual

Category
Light depilation
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI