Frigidaire FGQ1442ES3 Installation guide

Category
Electric laundry dryers
Type
Installation guide
Installation Instructions
Gas & Electric Dryer
Instructionsd'lnstallation
r
Secheuse a Gaz ou Electrique
instrucciones para la instalaci6n
Secadora a Gas y Electrica
\
www.frigidaire.com P/N 137101400 (0806)
CONTENTS
Pre-lnstallation Requirements .......................................................................................................................................... 2
Electrical Requirements .................................................................................................................................................. 3
Gas Supply Requirements ............................................................................................................................................... 3
Exhaust System Requirements ...................................................................................................................................... 3-5
Location of Your Dryer.................................................................................................................................................... S
Rough-In Dimensions ..................................................................................................................................................... 6
Unpacking ................................................................................................................................................................... 7
General Installation ....................................................................................................................................................... 7
Replacement Parts........................................................................................................................................................ 7
Mobile Home Installation ............................................................................................................................................... 8
Reversing Door Swing ................................................................................................................................................. 8-10
Electrical Installation .................................................................................................................................................... 11
Grounding Requirements .............................................................................................................................................. 11
Gas Connection ............................................................................................................................................................ 11
Electrical Connections--3-wire ....................................................................................................................................... 12
Electrical Connections--4-wire ........................................................................................................................................ 12
Francais......................................................................................................................................................................... 13-23
Espahol...................................................................................................................................................................... 24-34
SAFETY INSTRUCTIONS
Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier.
install the clothes dryer according to the manufacturer's instructions and local codes.
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the dryer is
installed correctly and safely. Leave these instructions near the Dryer after installation for future reference.
NOTE: The electrical serviceto the Dryer must conform with localcodes and ordinances and the latest edition of the National Electrical
Code, ANSI/NFPA70, or in Canada, the Canadian electrical code C22.1 part 1.
NOTE: The gasserviceto the Dryer must conform with local codes and ordinances and the latest edition of the National FuelGasCode
ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000
NOTE: The Dryer isdesigned under ANSIZ 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions for HOME USE only.
This Dryer is not recommended for commercial applications such as restaurants or beauty salons, etc.
RiSK OF FIRE, For your safety the information in this manual must be followed to minimize the risk of fire or
explosion or to prevent property damage, personal injury or lossof life. SAVE THESEINSTRUCTIONS.
Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Your safety and the safety of others is very important.
We have provided many important safety messages in the Use & Care Guide, Operating Instructions, Installation Instructions and on
your appliance. Always read and obey all safety messages.
This isthe safety alert symbol. This symbol alerts you to hazards that can kill or hurt you or others. All safety messages
will be preceded by the safety alert symbol and the word "DANGER" or "WARNING". These words mean:
You will be killed or seriously injured if you don't follow instructions.
You can be killed or seriously injured ff you don't follow instructions.
All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the
instructions are not followed.
PRE-INSTALLATION REQUIREMENTS
Tools and Materials Required for installation:
1. Phillips head screwdriver. 6.
2. Channel-lock adjustable pliers. 7.
3. Carpenter's level. 8.
4. Flat or straight blade screwdriver. 9.
5. Duct tape.
Rigid or flexible metal 4 inch (10.2 cm) duct.
Vent hood.
Pipe thread sealer (Gas).
Plastic knife.
ELECTRICAL REQUIREMENTS
i ELECTRICDryer
CIRCUIT- individual 30 amp. branch circuit fused with 30 amp.
time delay fuses or circuit breakers.
Use separately fused circuits for washers and dryers, and DO
NOToperate a washer and a dryer on the same circuit.
POWER SUPPLY- 3 wire or 4-wire, 240 volt, single phase, 60
Hz,Alternating Current.
]
POWER SUPPLYCORD KIT- 3 wire - the dryer MUSTemploy a
3-conductor power supply cord NEMA 10-30 type SRDTrated at
240 volt AC minimum, 30 amp., with 3 open end spade lug
connectors with upturned ends or closed loop connectors and
marked for use with clothes dryers. See ELECTRICAL
CONNECTIONSFORA 3-WIRE SYSTEM.
GAS SUPPLY REQUIREMENTS
Replace copper connecting pipe that is not
plastic-coated. Stainless steel or plastic-coated brass MUST
be used.
1. Installation MUSTconform with local codes,or in the absence
of local codes, with the National FuelGasCode, ANSIZ223.1
(latest edition).
,
3.
4 wire - The dryer MUST employ a 4-conductor power supply 4.
cord NEMA 14-30 type SRDTor ST(asrequired) rated at 240 volt
AC minimum, 30 amp., with 4 open end spade lug connectors 5.
with upturned ends or closed loop connectors and marked for use
with clothes dryers. See ELECTRICALCONNECTIONS FOR A 4-
WIRE SYSTEM.
(Canada - 4-wire power supply cord is installed on dryer.) 6.
WARNING - Risk of Shock, Appliance grounded to neutral
conductor through a link. Grounding through the neutral link is
prohibited for (1) New branch circuit installations (2) mobile homes;
(3) recreational vehicles; and (4) areas where local codes do not
permit grounding through the neutral, (1) disconnect the link from
the neutral, (2) usegrounding terminal or leadto ground appliance
in accordance with local codes and (3) connect neutral terminal
or lead to branch circuit neutral in usual manner (if the appliance
isto be connected by means of a cord kit, use4-conductor cord
for this purpose). USECOPPERCONDUCTOR ONLY.
OUTLET RECEPTACLE- NEMA 10-30R receptacle to be located
so the power supply cord is accessible when the dryer is in the
installed position. (Canada - NEMA 14-30R receptacle.)
NEMA 10-30R NEMA 14-30R
i GAS Dryer ]
CIRCUIT- Individual 15 amp. branch circuit fused with a 15 amp.
maximum time delay fuse or circuit breaker.
POWER SUPPLY- 3 wire, 120 volt single phase,60 Hz,Alternating
Current.
POWER SUPPLYCORD - The dryer isequipped with a 120 volt 3-
wire power cord.
NOTE: Do not under any _f _t_ _
circumstances remove
grounding prong from
plug.
G PRONG
,
The gas supply line should be of 1/2 inch (1.27 cm) pipe.
If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
The gas supply line MUSThave an individual shutoff valve.
A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible for
test gauge connection, MUST be installed immediately
upstream of the gas supply connection to the dryer.
The dryer MUSTbe disconnected from the gas supply piping
system during any pressure testing of the gas supply piping
system at test pressures in excess of 1/2 psig (3.45 kPa).
Thedryer MUSTbe isolated from the gassupply piping system
during any pressure testing of the gas supply piping system
at test pressures equal to or less than 1/2 psig (3.45 kPa).
EXHAUST SYSTEM REQUIREMENTS
Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible
metal duct and approved vent hood which has a swing-out
damper(s) that open when the dryer is in operation. When the
dryer stops, the dampers automatically dose to prevent drafts
and the entrance of insects and rodents. Toavoid restricting the
outlet, maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or anyother obstruction.
The following are specific requirements for
proper and safe operation of your dryer. Failure to follow
these instructions can create excessive drying times and
fire hazards.
Do not install a dothes dryer with flexible
plastic venting materials. If your present system is made up
of plastic duct or metal foil duct, replace it with a rigid or semi-
rigid metal duct. InCanada and the United States if metal (foil
type) duct is installed, it must be of a specific type identified by
the appliance manufacturer assuitable for usewith clothes dry-
ers and in the United States must also comply with the Outline
for Clothes Dryer Transition Duct, ULstandard 2158A. Flexible
venting materials are known to collapse, be easily crushed and
trap lint. These conditions will obstruct clothes dryer airflow and
increase the risk of fire. Ensure the present duct is free of
any lint prior to installing dryer duct.
f
iI _ i i_i
ii _iII_
\,y
Correct
DO
Correct
Incorrect
E
Incorrect
- Risk of Fire - A clothes dryer must be ex-
hausted outdoors. Do not exhaust dryer into a chimney, a
wall, a ceiling, an attic, a crawl space or any concealed space
of a building A clothes dryer produces combustible lint. If the
dryer is not exhausted outdoors some fine lint will be expelled
into the laundry area. An accumulation of lint in any area of the
home can create a health and fire hazard. The dryer must be
connected to an exhaust outdoors, Regularly inspect the
outdoor exhaust opening and remove any accumulation of lint
around the outdoor exhaust opening and in the surrounding
area.
Do not allow combustible materials (for ex-
ample: clothing, draperies/curtains, paper) to come in con-
tact with exhaust system. Thedryer MUSTNOT be exhausted
into a chimney, a wall, a ceiling, or any concealed space of a
building which can accumulate lint, resulting in a fire hazard.
Exceeding the length of duct pipe or num-
ber of elbows allowed in the "MAXIMUM LENGTH" charts
can cause an accumulation of lint in the exhaust system. Plug-
ging the system could create a fire hazard, as well as increase
drying times.
Do not screen the exhaust ends of the vent
system, nor use any screws, rivets or other fastening means
that extend into the duct and catch lint to assemble the
exhaust system, Lint can become caught in the screen, on the
screws or rivets, clogging the duct work and creating a fire haz-
ard as well as increasing drying times. Use an approved vent
hood to terminate the duct outdoors, and sealalljoints with duct
tape. All male duct pipe fittings MUSTbe installed downstream
with the flow of air.
Explosion hazard. Do not install the dryer
where gasoline or other flammables are kept or stored. If
the dryer is installed in a garage, it must be a minimum of 18
inches (45.7 cm) above the floor. Failure to do so can result in
death, explosion, fire or burns.
Number
of
90 °
Turns
0
1
2
3
4
Number
of
90 °
Turns
0
1
2
3
MAXIMUM LENGTH
of 4" (10.2 cm) Dia. Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
Louvered
(10.2 cm)
50 ft.(18.28 m)
52 ft.(15.84 m) 40 ft.(12.19 m)
44 ft.(13.41 m) 32 ft. (9.75 m)
32 ft.(9.75 m) 24 ft. (7.31 m)
28 ft.(8.53 m) 16 ft. (4.87 m)
MAXIMUM LENGTH
(6.35cm)
48 ft.(14.53 m)
of 4" (10.2 cm) Dia. Flexible Metal Duct
VENT HOOD TYPE
_(Preferred)
I Louvered
_10.2 cm)
30 ft. (9.14 m)
22 ft. (6.71 m)
14 ft. (4.27 m)
(6.35cm)
18ft. (5.49m)
14 ft. (4.27 m)
lO ft. (3.05m)
NOT RECOMMENDED
CT
INSTALL MALE FITTINGS IN CORRECT DIRECTION
In installations where the exhaust system isnot described in the
charts, the following method must be used to determine if the
exhaust system is acceptable:
1. Connect an inclined or digital manometer between the dryer
and the point the exhaust connects to the dryer.
2. Setthe dryer timer and temperature to air fluff (cool down)
and start the dryer.
3. Read the measurement on the manometer.
4. The system back pressure MUSTNOTbe higher than 0.75
inches of water column. If the system back pressure is less
than 0.75 inches of water column, the system isacceptable.
If the manometer reading ishigher than 0.75 inchesof water
column, the system istoo restrictive and the installation is
unacceptable.
Although vertical orientation of the exhaust systemisacceptable,
certain extenuating circumstances could affect the performance
of the dryer:
• Only the rigid metal duct work should be used.
• Ventingverticalthrougharoofmayexposetheexhaustsystem
todowndraftscausinganincreaseinventrestriction.
Runningtheexhaustsystemthroughanuninsulatedareamay
causecondensationandfasteraccumulationoflint.
Compression or crimping of the exhaust system will cause an
increase in vent restriction.
The exhaust system should be inspected and cleaned a minimum
of every 18 months with normal usage. The more the dryer is
used, the more often you should check the exhaust system and
vent hood for proper operation.
EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or left
side of the cabinet or the bottom of the dryer. On gas dryers,
exhausting can beto the right side of the cabinet or the bottom of
the dryer. Directional exhausting can be accomplished by install-
ing ExhaustKit, P/N131456800, available through your parts dis-
tributor. Follow the instructions supplied with the kit.
EXHAUST DUCT LOCATING DIMENSIONS
3 3/4"
AS OTHER SIDE
3 3/4"
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES REAR TOP FRONT
Alcove 0(0cm) 0(0cm)
Closet 0 (0 cm) 0 (0 cm) 1 (2.54 cm)
Closet door ventilation required: 2 Iouvered openings each 60
square inches (387 square centimeters)-- 3 inches (7.6 cm) from
bottom and top of door.
This dryer MUST be exhausted outdoors.
5 Thefollowing illustrations show minimum clearancedimensions
for proper operation in a recessor closet installation.
LOCATION OF YOUR DRYER
DO NOTINSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1
inch (2.54 cm).
INSTALLATION IN RECESSOR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUSTbe exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same
closet as the Gasdryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
,
A minimum of 120 squareinches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, isrequired.
Air openings are required to be unobstructed when a door is
installed. A Iouvered door with equivalent air openings for the
full length of the door isacceptable.
II
ii mm
---_,_--0 (Ocm)
II
II
CLOSET DOOR
o" (Ocrn)
1" (2.54 cm)
II
u
_11 "_
II
II
0"(0 cm)
ii
_11 _
Dryer Installation Dimensions
Free-Standing & Under Counter
48.5" To clear open door
(123.19cm)
D
i
(72.39cm)
28.5"
Gas supply pipe
on rear of unit
\
(5. 72cm)
2.25 _
5.0" (12.7cm)
Center line height
rear, right, left
vent
4.375" To side exhausts (11.12cm)
5.875" To base exhaust (14.93cm)
27.25 to front of cabinet (69.22cm)
27.75 to clear knobs (70.49cm)
28.5 to clear door handle (72.39cm)
_r_
'j,
0 o,_
i.......i
D
i
j.'r',_
r i- J
i
To rear &
base exhaust.,
27.0"
l=
(68. 58cm)
Electrical supply
on rear of unit
/
/
36"
(91.44cm)
(94.29cm)
Stacked Dryer Installation Dimensions
J
(11.12cm)
4.375"
Side
exhausts
41.00"
(104.14cm)
height for rear,
right, left vents
T
72.00"
(182.88cm)
Ja
28.25" to front of cabinet(71.76cm)
28.75" to clear knobs (73.03cm)
29.5" to clear door handle (74.93cm)
49" to clear open door(124.46cm)
4
(34.29cm)
13.5" <
Gas supply pipe
on rear of unit
i
JI_ , 'dl"
2.375"
(6.o3cm)_
38.25"
(97.16cm)
(68. 58cm)
27.0"
001
°_,
l
i
t ..-r-.
--_--+--4-
l
0 i.
ILl 0
UNPACKING
1. Using the four shipping carton corner posts (two on each side),
carefully lay the dryer on its left side and remove the foam
shipping base.
Toprevent damage, do not usethe control panel
as a means to pick up or move the dryer.
2. Return the dryer to an upright position.
,
,
,
If your dryer does not operate, please review the "Avoid Ser-
vice Checklist" located in your Use and Care Guide before
calling for service.
Placethese instructions in a location near the dryer for future
reference.
NOTE: A wiring diagram islocated inside the dryer console or
under the top panel.
To stack your dryer on a compatible washer, visit web site
www, frigidaire.com, call your local dealer or call the Toll
Freenumber (1- 800 - 444 - 4944) to find your local distributor
to purchase stacking kit accessory part number STACKIT2.
FOAM
PAD
PACKING
,
GENERAL INSTALLATION
Connect the exhaust duct to outside exhaust system (seepages
3 and 4). Useduct tape to seal all joints.
,
With the dryer in its final position, adjust one or more of the
legs until the dryer isresting solid on all four legs. Placea level
on top of the dryer. The dryer MUST be level and resting
sofid on all four legs.
3. Plug the power cord into a grounded outlet. NOTE:Check to
ensure the power isoff at circuit breaker/fuse box before plug-
ging the power cord into the outlet.
4. Turn on the power at the circuit breaker/fuse box.
_ -" " ' Before operating the dryer, make sure the
dryer area is clear and free from combustible materials,
gasoline, and other flammable vapors. Also see that noth-
ing (such as boxes, clothing, etc.) obstructs the flow of
combustion and ventilation air.
5. Runthe dryer through a cycle check for proper operation.
NOTE: On gas dryers, before the burner will light, it isneces-
sary for the gas line to be bled of air. If the burner does not
light within 45 seconds the first time the dryer is turned on,
the safety switch will shut the burner off. If this happens, turn
the timer to "OFF" and wait 5 minutes before making another
attempt to light.
6. If your dryer does not operate, please review the "Avoid Ser-
vice Checklist" located in your Use and Care Guide before
calling for service.
REPLA CEMENT PARTS
Pedestal
A pedestal accessory, Model No. NLPWD15 (White),
NLPWD15GB (Glacier Blue), NLPWD15P (Platinum) and
NLPWD15E (Black), specifically designed for this dryer may be
used when elevating the dryer for ease of use. Failure to use
accessoriescertified by the manufacturer could result in personal
injury, property damage or damage to the dryer.
If replacements parts are needed for your dryer, contact the source
where you purchased your dryer, call 1-800-944-9044, or visit our
website, www.frigidaire.com, for the Frigidaire Company
Authorized PartsDistributor nearest you.
Label all wires prior to disconnection when
servicingcontrols. Wiring errorscan causeimproper and dangerous
operation. Verify proper operation after servicing.
Destroy the carton and plastic bags after the dryer
is unpacked. Children might use them for play. Cartons covered
with rugs, bedspreads, or plastic sheets can become airtight
chambers causing suffocation. Place all materials in a garbage
container or make materials inaccessible to children.
The instructions in this manual and all other
literature included with this dryer are not meant to cover every
possible condition and situation that may occur. Good safe practice
and caution MUST be applied when installing, operating and
maintaining any appliance.
,
,
MOBILE HOME INSTALLATION
Dryer MUSTbe exhausted outside (outdoors, not beneath the
mobile home) using metal ducting that will not support
combustion. Metal ducting must be 4 inches (10.16 cm)in
diameter with no obstructions. Rigid metal duct ispreferred.
If dryer isexhausted through the floor and area beneath the
mobile home isenclosed, the exhaust systemMUST terminate
outside the enclosure with the termination securely fastened
to the mobile home structure.
,
,
,
6.
When installing a gas dryer into a mobile home, a provision
must be made for outside make up air. This provision isto be
not lessthan twice the area of the dryer exhaust outlet.
This dryer MUST be fastened to the floor. Mobile Home
Installation Kit No. 346764 isavailable from your dealer.
Referto pages2 and 3 for other important venting requirements.
Installation MUST conform to current Manufactured Home
Construction & Safety Standard (which isa Federal Regulation
Title 24 CFR-Part32-80) or when such standard isnot applicable,
with American National Standard for Mobile Homes.
The dryer isdesigned under ANSI Z21.5.1 or ANSI/
UL2158 - CAN/CSA C22.2 (latest editions) for HOME USEonly.
\ )'
I
Correct
L
_iill
ii _: i _
DON'T
'\. S
incorrect
L
REVERSING DOOR SWING
Sofid Door Reversing Instructions:
1. Open door and remove four (4) plugs in the door opening
opposite the hinges. Retain all parts for uses later, un-
less otherwise noted. Note: Use care in removing plugs
in not scratching paint on the front panel.
REMOVE 4 SCREWS
(ONE FROM EACH
HINGE FIRST)
,
Begin removing the four (4) screws that attach the hinge
to the front panel. Forbest results, start by only removing
one screw per hinge. Then only loosen the two remaining
screws while firmly holding door to prevent damage to
hinge, front panel or door. After the remaining screws are
loosened, continue to remove all.
3. Placedoor handle side down on a towel or pad to prevent
any possible scratches to door. Remove all remaining
four (4) screws between hinge and door.
4. Remove four (4) screws on opposite side of door.
5. Separateinner door from outer door by placing a flat screw
driver or putty knife. Rotate the inner door 180 degree
and reassemble the two door halves.
6. Install four (4) screws securing door halves where hinge
was previously attached.
7. Install four (4) screws securing hinge to door assembly.
8. Remove striker and discard.
9. Remove square plug and reinstall in hole striker was just
removed.
l O.Install striker (included in literature bag)into hole square
plug was previously installed.
11.Grasping firmly the top of the door, position the door near
the door opening and align the top hinge hole to the top
hole in the front panel door opening. Once the first screw
is started, attach the second screw to the lower hinge.
Once both screws are tightened, install the remaining
two screws.
Window Door Reversal Instructions
Figure 1
1.Open door and remove four (4) plugs in the door opening
opposite the hinges. Retain all parts for uses later, unless
otherwise noted. (Figure 1) Note: Use care in removing plugs
in not scratching paint on the front panel.
Figure 4
5. Remove two (2) door handle screws and two (2) hole plugs
from door. Again taking care not to scratch paint on door.
(Figure 4)
Figure 2
2. Begin removing the four (4) screws that attach the hinge to
the front panel. (Figure 2) For best results, start by only
removing one screw per hinge. Then only loosen the two
remaining screws while firmly holding door to prevent damage
to hinge, front panel or door. After the remaining screws are
loosened, continue to remove all.
Figure 5
6. Pull handle away from door assembley. (Figure 5)
Figure 6
7. Separate the outer door from the inner door assembly with
a putty knife or flat screw driver. (Figure 6)
Figure 3
3. Placedoor on a towel or pad handle side down to prevent
any possible scratches to door. Remove all remaining four (4)
screws between hinge and door. (Figure 3)
4. Remove four (4) screws from side of door opposite of where
hinge was mounted.
Figure 7
11. Reassemble lens to transition ring with holes to install
handle on right-hand side of door assembly. For proper fit
insure the retention tabs on transition ring are on top of lens
8. Remove lens locating screw. (Figure 7)
Figure 8
9. Disengaging several of the retention tabs and pull lens away
from the transition ring. (Figure 8)
Figure 9
Figure 10
Figure 11
12. Reassemblyouter door to inner door assembly. (Figure 11)
13. Install four (4) screws securing hinge to door assembly in
the new location, take note to place hinge in correct
orientation.
14. Install four (4) screws into holes that had secured the
hinge.
15. Remove striker and discard.
16. Remove square plug and reinstall in hole striker was just
removed.
17. Install striker (included in literature bag) into hole square
plug was previously installed.
10. Remove two (2) transition ring plugs and reinstall on
previous handle side. (Figures 9 and 10)
Figure 12
18. Reinstall door handle by placing the handle mounting
bossesthrough holes in lens and transition ring and installing
screws through inner door and tighten into handle bosses.
(Figure 12).
19. Grasping firmly the top of the door, position the door near
the door opening and align the top hinge hole to the top hole
in the front panel door opening. Once the first screw isstarted,
attach the second screw to the lower hinge. Once both screws
are tightened, install the remaining two screws.
20. Install four (4) plugs into the front panel door opening
where hinges were originally installed.
ELECTRICAL INSTALLATION
I ELECTR/CDryer I
The following are specific requirements for
proper and safe electrical installation of your dryer. Failure
to follow these instructions can create electrical shock and/
or a fire hazard.
This appliance MUST be properly grounded.
Electrical shock can result if the dryer is not properly grounded.
Follow the instructions in this manual for proper grounding.
Do not use an extension cord with this dryer.
Some extension cords are not designed to withstand the amounts
of electrical current this dryer utilizes and can melt, creating
electrical shock and/or fire hazard. Locate the dryer within reach
of the receptacle for the length power cord to be purchased,
allowing some slack in the cord. Refer to the pro-installation
requirements in this manual for the proper power cord to be
purchased.
A U.L. approved strain relief must be installed
onto power cord. If the strain relief isnot attached, the cord can
be pulled out of the dryer and can be cut by any movement of the
cord, resulting in electrical shock.
Do not use an aluminum wired receptacle with
a copper wiredpower cord andplug (or vice versa). A chemical
reaction occurs between copper and aluminum and can cause
electrical shorts. The proper wiring and receptade is a copper
wired power cord with a copper wired receptacle.
NOTE: Dryers operating on 208 volt power supply will have longer
drying times than operating on 240 volt power supply.
GROUNDING REQUIREMENTS
I USA ELECTR/CDryer 1
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt asto whether the appliance
isproperly grounded.
For a grounded, cord-connected dryer:
1. The dryer MUSTbe grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electricalshock
by a path of least resistance for electrical current.
,
If your dryer isequipped with a power supply cord having an
equipment-grounding conductor and a grounding plug, the
plug MUST be plugged into an appropriate, copper wired
receptacle that is properly installed and grounded in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician. Do not modify plug provided
with the appliance.
-i
Canadian ELECTR/CDryer j
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt asto whether the appliance
isproperly grounded.
Fora grounded, cord-connected dryer:
1. The dryer must be grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.
,
Since your dryer isequipped with a power supply cord having
an equipment-grounding conductor and a grounding plug, the
plug must be plugged into an appropriate outlet that isproperly
installed and grounded in accordance with all local codes and
ordinances. If in doubt, call a licensed electrician. Do not
modify plug provided with the appliance.
ALL GASDryers
1.The dryer isequipped with a three-prong (grounding) plug
for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong
from the plug.
,
GAS CONNECTION
Remove the shipping cap from gas pipe at the rear of the
dryer.
NOTE: DO NOTconnect the dryer to L.R gas servicewithout
converting the gasvalve.An L.Rconversion kit must be installed
by a qualified gas technician.
2.Connect a 1/2 inch (1.27 cm)I.D, semi-rigid or approved pipe
from gas supply line to the 3/8 inch (0.96 cm) pipe located on
the back of the dryer (seepages 6 and 7). Use a 1/2 inch to 3/
8 inch (1.27 cm to 0.96 cm) reducer for a connection. Apply
an approved thread sealer that is resistant to the corrosive
action of liquefied gases on all pipe connections.
3. Open the shutoff valve in the gas supply line to allow gas to
flow through pipe.
4. Testall connections by brushing on a soapy water solution.
NEVER test for gas leaks with an open flame.
For a permanently connected dryer:
1. ThedryerMUSTbe connected to a grounded metal, permanent
wiring system;or an equipment grounding conductor must be
run with the circuit conductors and connected to the
equipment-grounding terminal or lead on the appliance.
11
VALVE OPEN /
GAS FLOW POSITION
[
1.
,
,
,
,
,
,
,
ELECTRICALCONNECTIONS
FOR 3- WIRE SYSTEM
USA ELECTRICDryer
J
Remove the screws securing the terminal block access cover
and the strain relief mounting bracket located on the back of
the dryer upper corner.
install a U.L. approved strain relief into the power cord entry
hole of the mounting bracket. Finger tighten the nut only at
this time.
GREEN
GROUND
SCREW
SILVERTERMINAL
NEUTRAL
GROUND
WIRE
IUT
TIGHTEN NUT
TO THESE
THREADS
RELIEF
MOUNTING
BRACKET
POWER CORD
Thread a U.L. approved 30 amp. power cord, NEMA 10-30
type SRDT,through the strain relief.
Attach the power cord neutral (center wire) conductor to the
silver colored center terminal on the terminal block. Tighten
the screw securely.
Attach the remaining two power cord outer conductors to the
outer brass colored terminals on the terminal block. Tighten
both screws securely.
Do not make a sharp bend or crimp wiring/
conductor at connections.
Reattach the strain relief mounting bracket to the back of the
dryer with two screws. Tighten screws securely.
Tighten the screws securing the cord restraint firmly against
the power cord.
Tighten the strain relief nut securely so that the strain relief
does not turn.
9. Reinstall the terminal block cover.
[
1.
,
,
ELECTRICALCONNECTIONS FOR4-WIRE SYSTEM
USA ELECTRICDryer
]
Remove the screws securing the terminal block accesscover
and the strain relief mounting bracket located on the back of
the dryer upper corner.
Install a U.L. approved strain relief in the entry hole of the
mounting bracket. Finger tighten the nut only at this time.
Remove the ground wire from the green ground screw
located above the terminal block.
GREEN POWER CORD
GREEN GROUND WIRE
GROUND _ SILVERTERMINAL
SCREW _ [_._,_.._ . /
_ __:_TERMINALBLOCK
NEUTRAL-- YY BACK 'o H? g2UT
A NUT
_/// RELIEF
/ MoRuENTING
/ /POWERCORD
4. Thread a U.L. approved 30 amp power cord, NEMA 14-30
type STor SRDTthrough the strain relief.
TYPICAL 4
CONDUCTOR_ TYPICAL 4 BLACK
COND UCTOR _ WHITE
30 AMP NEMA 14-30 TYPE SRDT OR ST _GREEN
5. Attach the green power cord ground wire to the cabinet with
the green ground screw.
,
Attach the white (neutral) power cord conductor from the
power cord and the neutral ground wire from the dryer harness
to the silver-colored center terminal on the terminal block.
Tighten the screw securely.
7. Attach the red and black power cord conductors to the outer
brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly against
the power cord.
9. Tighten the strain relief nut securely so the strain relief does
not turn.
l O.Reinstallthe terminal block access cover.
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Frigidaire FGQ1442ES3 Installation guide

Category
Electric laundry dryers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI