Bosch DKE96 User manual

Category
Cooker hoods
Type
User manual
Bosch
ventilation
installation
manual
DKE96
Table of Contents
Safety ...................................................................................................................... 1
Installation ............................................................................................................... 2
Before You Begin .................................................................................................................... 2
Installation Procedure.............................................................................................................. 4
Service.................................................................................................................... 7
Before Calling Service............................................................................................................. 7
Product Data Plate............................................................................................................. 7
Questions?
1-800-944-2904
www.boschappliances.com
5551 McFadden Ave.
Huntington Beach, CA 92649
We look forward to hearing from you!
1901 Main Street
Irvine, CA 92614
English 1
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE AFTER INSTALLATION IS COMPLETE.
IMPORTANT: SAVE FOR THE LOCAL INSPECTOR'S USE.
Important Safety
Instructions
WARNING: Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual. For assistance
or additional information consult aqualified installer, service agency,or manufac-
turer.
•Have the installer show you the location of the circuit breaker or fuse. Markit
for easy reference.
•Be sure your appliance is properly installed and grounded by a qualified tech-
nician.
Equipment and Usage Safety Requirements
•Before you plug in an electrical cord, be sure all controls areinthe OFF posi-
tion.
•WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURYTO PERSONS, OBSERVE THE FOLLOWING:
•Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
•Before servicing or cleaning the unit, switch power off at service panel
and lock service panel. This will prevent power from being switched on
accidentally. When the service panel cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
•Installationwork and electrical wiringmust be done by qualified person(s)
in accordance with all applicable codes & standards, including fire-rated
construction.
•Sufficient make-up air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent back-
drafting. Follow the heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire Protection Associa-
tion (NFPA), the American Society for Heating, Refrigeration and Air Condi-
tioning Engineers (ASHRAE), and the local code authorities.
•Due to the size and weight of this unit, two installersare recommended.
•When cutting or drilling into wall or ceiling, do not damage electrical wiring or
other hidden utilities.
•To properly exhaust air, be sure to duct air outside. Do not vent exhaust air
into spaces within walls, ceilings, attics, crawl spaces, or garages.
•Install this hood in accordancewith all requirements specified.
•The hood is equipped with an internal blower. Other ventilator blowers CAN-
NOT be substituted.
•WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT-
WORK.
•WARNING: Turn off power circuit at service panel and lock out panel before
wiring this appliance.
Safety
English 2
•CAUTION: This unit is approved for use with residential appliances. For gen-
eral residential kitchen ventilating use only. DO NOT use to exhaust hazard-
ous or explosive materials or vapors. Vent unit to the outside.
•To reducethe risk of fire or electric shock, do not use the fan with any solid-
state speed control device.
•This appliance has been found to be in compliance with UL507 Standard for
Electric Fans and CAN/CSA-22.2 No. 113 Canadian Standard for Fans and
Ventilators. It is the responsibility of the owner and the installer to determine if
additional requirements or standards apply in specific installations.
Before You Begin
Tools and Parts
Needed
1. Metal Duct Cover (optional)
2. Ductwork as necessary (style varies)
3. Duct Tape
4. Phillips Head Screwdriver
5. Drill with 1/4” bit (6 mm)
6. Tape Measure
7. Screwdriver
Parts Included 1. Chimney sections (2)
2. Filter
3. Hood
4. Transition
5. One Way Damper
6. Screws, 5x60 (6)
7. Sheet Metal Screws, 3.9 (2)
8. UX6 plugs (6)
9. Positioning Templates (2)
If parts aremissing or damaged, call the number or write to the address listed
inside the front cover.
General Information The hood is equipped with an internal blower. It is not designed for use with a
remote blower.
Hood installation height above cooktop is the user’s preference. The lower the
hood above the cooktop, the moreefficient the capturing of cooking odors,
grease, and smoke. This hood has been approved for installations as low as 30
(760 mm) and as high as 36” (900 mm) above the cooktop.The lower height may
be inconvenient for tall people and large cooking vessels.
In addition, the chimney sections, when fully extended, measure 42 3/4” (1090
mm) tall. In order for the upper chimney section to meet the ceiling (or surface
above), the highest allowable ceiling height is 91/2 (3 m)(assumes the hood is
installed 36” (900 mm) above the cooktop).
Installation
English 3
Ducting Recommenda-
tions
The hood can be ductedto the outside or usedwith a recirculation unit. The recir-
culation unit is available from your dealer.
For the most efficient air flow exhaust, use a straight duct run or as few elbows as
possible.
Do not use flex ducting. Always usemetal ductworkwith minimum diameter of 6”
(150 mm). A transition is necessary to connect to larger diameter ductwork or to
square ductwork.
COLD WEATHER installations should have an additional backdraftdamper
installed to minimize backward cold air flow and a nonmetallic thermal break to
minimize conduction of outside temperaturesas part of the ductwork. The damper
should be on the cold air side of the thermal break. The break should be as close
as possible to where the ducting enters the heated portion of the house.
Always install a metal vent cover where the ductwork exits the house.
Make-Up Air: Local building codes may require the use of make-up air systems
when using ducted ventilation systems greater than specified CFM of air move-
ment. The specified CFM varies from locale to locale. Consult your HVAC profes-
sional for specific requirements in yourarea.
Overall Dimensions The overall dimensions are:
•Width: 35 1/2" (900 mm); 30” (760 mm)
•Depth: 20 1/2" (520 mm)
•Height: 28-43” (715-1100 mm), depending on chimney extension
Mounting Requirements The hood must be mounted through the back wall. It cannot be mounted from
above. See “General Information” on page 2 for suggestions for determining hood
height.
For safety purposes, the wall must be able to support three times the weight of the
hood. See “Minimum Weight Requirements” on page 3 for the minimum amount
of weight the wall must support. Note: At least one screw must be installed
through a stud.
Figure 1: Overall Dimensions
30"
/
35
1/2"
(760
mm
/
900
mm)
20
1/2"
(520
mm)
28-43"
(715-1100 mm)
Table 1: Minimum Weight Requirements
Size With Recirculation Kit Without Recirculation Kit
30” (760 mm)189 lbs. (85.5 kg) 152 lbs. (69 kg)
36” (900 mm)202 lbs. (91.5 kg)167 lbs. (75.5 kg)
English 4
Power Requirements Electrical Specifications: 120V AC, 60Hz. 15A Branch Circuit
Installation Procedure
WARNING: To avoid electrical shock hazard, before installing,
switch power off at the service panel and lock the panel to prevent the
power from being switchedon accidentally.
1) Unpack Hood Pull hood from outer packaging. Remove and discard all packaging materials.
Remove filter and set aside (See Use and Care manual for removal instructions).
2) Prepare ductwork Install one-way damper so that the flap opens up. Press damper down into the
blower outlet until it is snug. Note: verify thatthe flap opens up (toward the ceiling)
before continuing. See “Prepare Ductwork” on page 4. If necessary,install transi-
tion, thermal break and additional backdraft damper.
3) Prepare Wall See “General Information” on page 2 for recommended installation height and
“Mounting Requirements” on page 3 for information on wall requirements.
Once the preferred height is determined, draw a line at the verticalcenterline of
the cooking appliance.
Use the installation template to locate and mark the screw holes. Drill 1/4” (6 mm)
pilot holes (4 holes for hood screws and 2 holes for chimney screws). Install plugs
Figure 2: Prepare Ductwork
English 5
in screw holes so that they are flush with the wall.Note: At least one screw must
be installed through astud. Leave a 3/8” (6 mm) of each screw exposed.
4) Attach ChimneyMounting
Bracket
Attach spacers to holes on chimney mounting bracket arms, as seen in “Attach
Mounting Brackets” on page 5.
Attach chimney mounting bracket to wall through chimney screwholescreated in
previous step. Use two screws.
5) Hang the Hood Place the hood by sliding the mounting holesin the top of the hood over the top
hood screws. Check and adjust for level. Tighten the screws.
Figure 3: Prepare Wall
lower hood screw holes
upper hood screw holes
chimney screw holes
centerline
template
30" min.
Figure 4: Attach Mounting Brackets
English 6
Note: Be sure that the glass screen is not touching the back wall.
Install two lower hood screws from underneath.
6) Connect to Ductwork Connect hood to ductwork in house.
7) Connect Electric Plug electrical cord into grounded outlet. Note: The hood requires a 120V AC,
60Hz., 15A Branch Circuit.
8) Install Chimney Remove protective film from both sections of chimney.
Connect the sections, one inside the other. For recirculation, the slots in the upper
chimney section should be at the end closest to the ceiling. When venting to the
outside, the top section can be turned upside down to conceal the vents.
CAUTION: Be careful not to scratch chimney surface when connecting. Slide tem-
plates between the two chimney sections to protect them.
Figure 5: Hang the Hood
Figure 6: Install Lower Hood Screws
1/4"
English 7
Insert bottom edge of chimney into top of hood. Slide upper section up until it is
flush withthe surface above. Attachtochimney mounting bracket with two sheet
metal screws.
9) Final Steps Remove templates from between chimney sections if necessary. Remove protec-
tive film from hood. Install grease filters (See Use and Care Manual).
Test the installation.
Note: Be sure to check for backdraft. With the blower on high, close the windows
and doors to the area to ensure that fan does not cause back drafting in any outlet
vent for another appliance.
Before Calling
Service
See Use and Care Manual for troubleshooting information. Refer to the Warranty
in the Use andCare Manual. Please be prepared with the information printed on
your product dataplate when calling.
Product Data Plate The data plate shows the model and serial number. It is located under the filter.
Keep your invoice or escrow papers for warranty validation if service is needed.
Figure7: Install Chimney
1.
2.
3.
Service
Figure 8: Data Plate Location
Data Plate
Filter
Table des matières
Sécurité ................................................................................................................... 1
Installation ............................................................................................................... 2
Avant de commencer .............................................................................................................. 2
Marche à suivre d’installation.................................................................................................. 4
Service .................................................................................................................... 7
Avant d’effectuer un appel de service..................................................................................... 7
Plaque signalétique............................................................................................................ 7
Questions?
1.800.944.2904
www.boschappliances.com
5551 McFadden Ave.
Huntington Beach, CA 92649
Nous attendons de vos nouvelles !
1901 Main Street
Irvine, CA 92614
Contenido
Seguridad................................................................................................................ 1
Instalación ............................................................................................................... 2
Antes de comenzar ................................................................................................................. 2
Procedimiento de instalación.................................................................................................. 4
Servicio ................................................................................................................... 7
Antes de solicitar servicio........................................................................................................ 7
Placa con información del producto................................................................................... 7
¿Preguntas?
1-800-944-2904
www.boschappliances.com
5551 McFadden Ave.
Huntington Beach, CA 92649
¡Estamos a sus ordenes!
1901 Main Street
Irvine, CA 92614
1901 Main Street, Suite 600 • Irvine • CA 92614 • 1-800-944-2904
www.boschappliances.com • © BSH Home Appliances Corporation
9000086314
920518
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Bosch DKE96 User manual

Category
Cooker hoods
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages