Cres Cor H137WSUA5DMFBC Owner's manual

Type
Owner's manual

This manual is also suitable for

Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 1 of 8
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
ELECTRICAL SPECIFICATIONS:
Model No. Volts Watts Amps Hertz Phase NEMA
H137WSUA5DMFBC 120 2000 16.7 60 1 5-20P
HOW TO INSTALL UNIT:
1. Place cabinet on level oor, in a well ventilated area.
2. Unpack and install inner pan slides parts.
3. Plug cord end into proper wall outlet.
Air is VERY HOT when door is opened.
WARNING
1. Push the switch on; the light will come on.
NOTE: The letters “LOTPR” (Low Temperature)
will show on the control panel until it
reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to
show 220°F. Push the knob to set the temperature.
Run the unit for one (1) hour.
3. Push the switch o the unit o and let cool.
4. Wipe the inside clean with detergent and hot water.
FIRST TIME OPERATION:
NOTE: A new cabinet needs to “burn o”
manufacturing oils and excess adhesive
before its rst use. Do NOT load food into
cabinet until this has been done!
HOW TO CHANGE FROM °C TO °F (if needed)
1. Push the switch on; the light will come on.
2. Push and hold the “SET” button and the button in
the lower left hand corner together for 5 seconds.
You are now entered into the menu.
3. Scroll over the”Unit” and change it to “C” , then
scroll to the “END”.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 2 of 8
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
HOW TO HOLD:
No water is needed in pan.
1. Push the switch on; the light will come on.
NOTE: The letters “LOTPR” will show on the control
panel until it reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to
a temperature between 140°F (60°C) and 220°F
(104°C). Push the knob to set the temperature.
3. Preheat the cabinet for 30 minutes.
NOTE: Press the “Display” button to see the actual
temperature inside the cabinet.
HOW TO HOLD WITH HUMIDITY:
Fill water pan with 4 gallons (15 liters) of HOT
water.
1. Push the switch on; the light will come on.
NOTE: The letters “LOTPR” will show on the control
panel until it reaches 80°F (26°C).
2. Push and hold knob for 5 seconds, then turn to a
temperature between 80°F (26°C) and 220°F (104°C).
Push the knob to set the temperature.
3. Push and hold knob for 5 seconds, then turn knob to
desired humidity value setting. Push the knob to set
the value number.
4. Preheat the cabinet for 1/2 hour (30 minutes).
NOTE: This cabinet operates with air temperature
priority. Humidity will only start after cabinet
is fully preheated. If cold or room temp water is
used, humidity build-up time will be longer.
"ON-OFF" SWITCH
X:\ENGINEER\FLSHEETS\FL2355 CONTROL PANEL
"HOT HOLDING"
DIGITAL CONTROL
"AQUATEMP"
DIGITAL CONTROL
ON-OFF LOW WATER LIGHT
HUMIDITY READING
ACTUAL CABINET
TEMPERATURE
DIGITAL CONTROL NOTES
*Press the “display” button to see the actual temperature
inside the cabinet (press again to shut o).
*Press the “display actual” button to see the approximate
relative humidity value (press again to shut o).
*Small letters in upper right corners of the displays are:
Hot Holding control: “S” = setpoint temperature
“A” = actual temperature
AquaTemp control: “S” = setpoint reading
(in increments of 5)
“A” = approximate relative
humidity reading
NOTE: When the low water light is on, the “A”
numbers will not be close to an accurate
reading, and the water heater will not heat.
NOTE: These settings are based on laboratory
conditions and may dier from conditions at the
point of use. Experiment with the settings
to determine what is best for your application.
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 3 of 8
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
Delime or descale water pan parts as required,
to prevent damaging build-up. WARRANTY
COVERAGE MAY BE AFFECTED WITHOUT
PROPER CLEANING.
Cleaning hints:
1. Wipe up spills as soon as possible.
2. Clean cabinet regularly to avoid heavy dirt build-up.
3. Make a test spot with cleaner.
4. Follow manufacturer’s directions on cleaner.
5. Do not mix cleaners.
6. Avoid drips and splashes.
7. Do not use “Cres Clean” on plastic parts or labels.
HOW TO CLEAN THE UNIT:
Soil Cleaner Method
CABINET
Inside
and
Outside
(Stainless Steel)
ROUTINE CLEANING Soap, Ammonia, or mild
*detergent and water.
1. Sponge on with cloth.
2. Rinse with water.
3. Wipe dry.
STUBBORN SPOTS AND
STAINS
Mild abrasive made for
stainless steel.
1. Apply with damp sponge or cloth.
2. Rub lightly.
BURNT-ON FOODS OR
GREASE
Chemical oven cleaner for
stainless steel.
Follow oven cleaner manufacturer’s
directions.
HARD WATER SPOTS
and SCALE Vinegar 1. Swab or wipe with cloth.
2. Rinse and dry.
*Mild detergents include soaps and non-abrasive cleaners.
NOTE: Gaskets are removable for cleaning.
BEFORE CLEANING CABINET:
1. Allow cabinet to cool.
2. Do NOT hose cabinet with water.
3. Do NOT get water on controls.
4. Do NOT use abrasives or harsh chemicals.
WARNING
DAILY MAINTENANCE:
WATER PAN
Drain, wipe and ll water pan daily. (Clear vinyl drain hose
is provided.)
1. Push hose onto drain nozzle under the cabinet base.
2. Turn knob to open the drain.
CABINET
1. Wipe the inside of the cabinet after daily use.
2. LEAVE DOORS SLIGHTLY OPEN TO FULLY
DRY INTERIOR.
How to use the Automatic Water Fill:
There is a water ll connection under the bottom left
rear of the oven. Remove the plug on the end of the
connector.
1. Connect the plastic tubing provided to the
connector and the other end to your water supply.
Turn water supply on.
2. Press and hold both the DISPLAY button and the
knob of the AquaTemp humidity control for ve
seconds.
3. Turn the knob until when the display shows FILL,
select “Y” for yes and press the knob to set.
4. Go to END to exit the menu. Auto water ll should
start.
To shut down:
1. Press and hold both the DISPLAY button and the
knob of the Aquatemp humidity control.
2. Turn the knob to FILL and push to enter. Select
“N” for no; go to END to exit the menu.
3. Turn o your water supply and clean out the water
pan after it cools.
NOTES: It is recommended to use treated water to
prevent failure of ll valve. If water supply pressure is
high, it is recommended to regulate it to make sure the
ll valve closes reliably.
HOW TO TURN UNIT OFF:
Push switch o; light will go out.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 4 of 8
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Convection
Humidity Oven FL-2373-BC
Rev. 1 (9/20) Page 12 of 17
5925 Heisley Road • Mentor, OH 44060-1833
MAINTENANCE INSTRUCTIONS
HOW TO ADJUST THE DOOR LATCH:
1. For vertical (up and down movement) adjustment:
a. Loosen (2) screws located in magnetic strike.
b. Move strike up or down for alignment to magnet on latch.
c. Tighten screws to secure
2. For horizontal (greater or lesser magnetic draw) adjustment:
a. Loosen (4) screws in door latch.
b. Move latch forward or backward to adjust magnetism.
c. Tighten screws to secure.
WARNING
IF OVEN GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is blown.
3. Switch is turned o.
4. Fuse on back of unit is blown.
If unit is NOT working, rst check the following causes:
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualied electrician.
Daily
Drain water pan and clean interior of unit as per instructions in FL-2373-BC
Weekly
Check hinges and latch and adjust as needed per instructions in FL-2373-BC
Monthly
Check that meat probe does not have any fraying wires or exposed conductors.
Replace as needed.
Check that cooling fans are operating when unit is running at cooking temps.
They are controlled by a thermal switch and may not kick on until unit has been
operating for some time.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Convection
Humidity Oven FL-2373-BC
Rev. 1 (9/20) Page 12 of 17
5925 Heisley Road • Mentor, OH 44060-1833
MAINTENANCE INSTRUCTIONS
HOW TO ADJUST THE DOOR LATCH:
1. For vertical (up and down movement) adjustment:
a. Loosen (2) screws located in magnetic strike.
b. Move strike up or down for alignment to magnet on latch.
c. Tighten screws to secure
2. For horizontal (greater or lesser magnetic draw) adjustment:
a. Loosen (4) screws in door latch.
b. Move latch forward or backward to adjust magnetism.
c. Tighten screws to secure.
WARNING
IF OVEN GETS TOO HOT OR WON’T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
1. Cord is unplugged from wall outlet.
2. Circuit breaker/fuse to wall outlet is blown.
3. Switch is turned o.
4. Fuse on back of unit is blown.
If unit is NOT working, rst check the following causes:
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement
of electrical components must be done by a qualied electrician.
Daily
Drain water pan and clean interior of unit as per instructions in FL-2373-BC
Weekly
Check hinges and latch and adjust as needed per instructions in FL-2373-BC
Monthly
Check that meat probe does not have any fraying wires or exposed conductors.
Replace as needed.
Check that cooling fans are operating when unit is running at cooking temps.
They are controlled by a thermal switch and may not kick on until unit has been
operating for some time.
Daily
Drain water pan and clean interior of unit as per instructions in FL-2355-BC
Weekly
Check hinges and latch and adjust as needed per instructions in FL-2355-BC
Monthly
Check that cooling fans are operating when unit power switch is on.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 5 of 8
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE
PERSONNEL ONLY
RISK OF FIRE OR ELECTRIC SHOCK
DO NOT OPEN
WARNING
TROUBLE-SHOOTING CHART:
FAILURE: POSSIBLE CAUSE:
1. Switch light or control display does NOT
light up.
1a. Circuit breaker/fuse to wall outlet is blown
1b. Cord is unplugged from wall outlet.
1c. Switch is “OFF.”
1d. Switch or control defective.
2. Unit gets too hot or won’t shut o. 2a. Relay or control defective.
UNPLUG UNIT FROM WALL OUTLET
3. Unit does not heat. 3. Defective heater, relay, blower or control.
4. No humidity 4a. Low water
4b. Air temperature set too high.
4c, Defective heater, relay or control.
Controller (Thermostats) Error codes:
err 00 - Temperature probe defective
err 01 - Water ll time out
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 6 of 8
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
REPLACEMENT PARTS:
120V 208V 240V
Blower Kit 0769-180-SS-K 0769-182-SS-K 0769-182-SS-K
Heater Kit, Air 2000W 0811-022-K 0811-185-K 0811-023-K
1470W 0811-019
Heater Kit, Water 1850W 0811-271 0811-278 0811-271
1500W 0811-314
High Limit (water pan) 0848-060 0848-060 0848-060
High Limit - 400°F 0848-033 0848-033 0848-033
Power Cord 2000W 0810-065-12-K 0810-039-07 0810-039-07
1500W 0810-029-06
Relay, Solid State 0857-136 0857-136 0857-136
Switch, Power 0808-125 0808-125 0808-125
Thermostat Control (Hot) 0848-092-40-K 0848-092-40-K 0848-092-40-K
Thermostat Control (Humidity) 0848-092-38-K 0848-092-38-K 0848-092-38-K
Thermostat Probe 0848-091-K 0848-091-K 0848-091-K
Terminal Block 0852-119 0852-119 0852-119
Transformer 0769-197 0769-197 0769-197
Vent Fan 0769-165 0769-174 0769-174
Water Pan Assembly 0756-037 0756-042 0756-037
Door, Complete (Stainless Steel) UA12/UA6/1834/1816 1221-579-K
UA5 1221-597-K
Door, Gasket (Stainless Steel) UA12/UA6/1834/1816 0861-185-K
UA5 0861-250-K
Door Hinge 0519-074-K
Door Latch 1006-122-01-K
Door Handle 0911-111
Handle, Side Pull 0911-087
Casters, 5” 0569-306-K
Casters, 5” w/brake 0569-306-BK
Wire Angles (Stainless Steel) 0621-281-SS-K
Pan Rack Insert Each (for -1834 Model) 1103-109
Clear Drip Pan 1017-058
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 7 of 8
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
VENT
FAN
POWER SWITCH
(REAR VIEW)
BLOWER
MOTOR
*MUST HAVE THERMAL GREASE
OR THERMAL PAD INSTALLED
BETWEEN RELAYS AND
MOUNTING SURFACES
SOLID STATE RELAY 2
WATER HEATER
L1 T1
A2(-)
A1(+)
RENAU CONTROL
*LOCKWASHER AND
NUT (OR DOUBLE
NUTS) IS REQUIRED
TO HOLD GROUND
TERMINAL TO
GROUND STUD
AIR HEATER
HIGH LIMIT 400F
SOLID STATE RELAY 1
AIR HEATER
L1 T1
A2(-)
A1(+)
RENAU CONTROL
WATER HEATER
HIGH LIMIT 300F
WATER
PROBE
AIR
PROBE
LOWER
FLOAT SWITCH
VENT
FAN
*PROBE WIRES RUN
DOWN OPPOSITE
SIDE FRAME RAIL
AS OTHER WATER
PAN WIRES
TB1
TRANSFORMER
2
1
4
3
1
2
3
4
5
6
5
6
8
7
7
8
10
9
910
11 12
11
12
13
13
14
14 15
16
17
18
17 18
19
20
19
20
21 22
21
22
23
24
23 24
25
25
26
26 27
28
28
OPTIONAL
DISCARD
WIRES 1
AND 2.
REPLACE
WITH
WIRES 41,
42, 43,
44 AND
WIRE AS
SHOWN:
41, 42 TO
TB1
43, 44 TO
POWER
SWITCH
41 42
43 44
N
N
L
L
45
46 47
45
46
47
AIR TEMP
LOOKING AT REAR
HUMIDITY
LOOKING AT REAR
TRANSFORMER WIRING 240V
G
FUSES
3A 3A
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
K3 K1 K2
P1 16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
K3 K1 K2
P1
GREY/RED
RED/YELLOW
BROWN/BROWN
WHITE/WHITE
BLACK/BLACK
BLUE/ORANGE
PURPLE/BLUE
YELLOW/GREY
WIRE COLORS: TRIAD/HAMMOND
BROWN/BROWN
WHITE/WHITE
BLACK/BLACK
BLUE/ORANGE
(TO TERMINAL BLOCK)
WIRING DIAGRAM:
Insulated
Hot Cabinets FL-2355-BC
Rev. 2 (12/20) Page 8 of 8
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H137 series Humidity Holding Hot Cabinet
BUC-EE’S PROGRAMMING REVISION J-08
WIRING DIAGRAM:
VENT
FAN
POWER SWITCH
(REAR VIEW)
BLOWER
MOTOR
*MUST HAVE THERMAL GREASE
OR THERMAL PAD INSTALLED
BETWEEN RELAYS AND
MOUNTING SURFACES
SOLID STATE RELAY 2
WATER HEATER
L1 T1
A2(-)
A1(+)
RENAU CONTROL
HUMIDITY
*LOCKWASHER AND
NUT (OR DOUBLE
NUTS) IS REQUIRED
TO HOLD GROUND
TERMINAL TO
GROUND STUD
AIR HEATER
HIGH LIMIT 400F
SOLID STATE RELAY 1
AIR HEATER
L1 T1
A2(-)
A1(+)
RENAU CONTROL
AIR TEMP
WATER HEATER
HIGH LIMIT 300F
WATER
SOLENOID
WATER LEVEL CONTROL
RELAY 3
WATER
PROBE
AIR
PROBE
LOWER
FLOAT SWITCH
UPPER
FLOAT SWITCH
VENT
FAN
*ONE PIGGYBACK
CONNECTOR USED ON
TERMINAL BLOCK: MUST BE
PLACED ON MIDDLE
TERMINAL FOR CLEARANCE
1
*PROBE WIRES RUN
DOWN OPPOSITE
SIDE FRAME RAIL
AS OTHER WATER
PAN WIRES
TB1
10
9
17
18
2
2
1
4
3
3
4
5
6
5
6
8
7
7
8
910
11 12
11
12
13
14 13
14 15
16
17 18
19
20
19
20
21 22
21
22
25
26
25
27
28
29
30
29
30
31
31
32
33 34
32
33
34
35
35
36
36
37
37 38
38
26
39
40
39
40
TRANSFORMER
OPTIONAL
DISCARD
WIRES 1
AND 2.
REPLACE
WITH
WIRES 41,
42, 43,
44 AND
WIRE AS
SHOWN:
41, 42 TO
TB1
43, 44 TO
POWER
SWITCH
41 42
43 44
N
N
L
L
TRANSFORMER
*UPPER FLOAT SWITCH
NEEDS TURNED UPSIDE
DOWN. ADDITIONALLY, IT'S
FLOAT NEEDS TURNED
UPSIDE DOWN TOO.
45
46 47
45
46
47
G
FUSES
3A 3A
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
K3 K1 K2
P1 16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
K3 K1 K2
P1
AB
4
7
1
9
6
3
BROWN
GRAY
RED
ORANGE
BROWN
RED
BLACK
"7 WIRE RENAU TRANSFORMER" WIRING
GREY/RED
RED/YELLOW
BROWN/BROWN
WHITE/WHITE
BLACK/BLACK
BLUE/ORANGE
PURPLE/BLUE
YELLOW/GREY
WIRE COLORS: TRIAD/HAMMOND
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Cres Cor H137WSUA5DMFBC Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI