  • Hello! I am an AI chatbot trained to assist you with the Korenix JetNet 6524G Quick Installation Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
JetNet 6524G Series
24-Port Gigabit Stackable Layer 3 Managed
Ethernet Switch
Quick Installation Guide
www.korenix.com
V1.0
Introduction
The JetNet 6524G is a 19-inch Gigabit Stackable Layer 3 Managed Switch, equipped with 24
10/100/1000 Base-TX ports and 4 Gigabit SFP combo ports delivering maximum throughput
and flexibility for high-density and ultra-high-speed connection. With stacking cable
installation, up to 8 units can be stacked together, allowing building a single-IP manageable
device and simultaneously providing 40G backplane across full duplex stacking links. The
ÀH[LEOHLQWHUIDFHGHVLJQDOORZV-HW1HW*WRSURYLGHXSWR*LJDELWSRUWVSHUVWDFN
and 384G bandwidth for building intelligent large-scale networks.
In addition to the 90-264VAC power-based JetNet 6524G model, Korenix provides the JetNet
6524GDC series, which support 24V or 48V power inputs and feature a FAN-less design with
-40~65
O
C wide operating temperature for severe industrial applications.
8QSDFNWKHER[\RXZLOO¿QG
The Rack Mount Managed Ethernet Switch
RS-232 DB9 (Null-Modem) console cable
Rack Mount kit
Power Cord (Depend on Country, JetNet 6524G-DC no Power Cord)
QIG
2.Interface Introduction
Hardware Installation
2.1 Front-Panel Components: The front panel of the Switch consists of LED indicators,
Gigabit Ethernet ports and four SFP (Mini-GBIC) Combo ports.
Comprehensive LED indicators display the status of the startup Self-test/Power, Status (of
the stacking master) and the port Link/Activity.
2.2 LED Indicators: The LED indicators of the front panel include Power, Console, and
Ethernet Port Link/Act.status. A bank of 24 LEDs (2 for each port) indicates link, activity
status, and connection speed for each port.
In the Real panel, the LEDs indicate the Stacking status. A band of 8 ports (4 for each
stacking port) indicates Status, RX, TX, Link of the 2 stacking ports.
21 22 23 24
21
22
23
24
Module
Link/Act
181614 20 22 24
171513 19 21 23
Link/Act
6428 10 12
5317 91 1
Orange
Green
Off
: 1Gbps
: 100Mbps
: 10Mbps
Power/
Self-test
Status
24G Rackmount Layer3
Managed Ethernet Switch
6524G
The AC power connector is a standard three-pronged connector that supports the power
cord. Plug the female connector of the provided power cord into this socket, and the male
side of the cord into a power outlet. The Switch automatically adjusts its power setting to
any supply voltage in the range from 100 ~ 240 VAC at 50 ~ 60 Hz.
The stacking connector is a standard CX4 type with 10G full duplex transmission
capability. There are Status, TX, RX and Link LED to indicate the status.
DC Power Input apply to the JetNet 6524G-DC
Follow below steps to wire JetNet 6524G-DC redundant DC power inputs. The power
range support 24V(18-36VDC) or 48V(36-72V) DC input. Choose the power input model
you preferred.
Note 1: It is a good practice to turn off input and load power, and to unplug power terminal
block before making wire connections. Otherwise, your screwdriver blade can inadvertently
short your terminal connections to the grounded enclosure.
Note 2: The range of the suitable DC electric wire is from 12 to 24 AWG.
2.3 Rear Panel Description: The rear panel of the Switch contains an AC power connector
or DC power connector, a RS-232 console port, the connector for the two stacking ports.
An RS-232 DCE console port is for setting up and managing the Switch via a connection
to a console terminal or PC using a terminal emulation program. The default baud rate is
115,200, N, 8, 1.
100-240V~, 50/60HZ
Console
115200,N,8,1
1
21
2
10G / Stack
Status
RX
TX
Link
1. Insert positive and negative wires into V+ and V- contacts
respectively of the terminal block connector
2. Tighten the wire-clamp screws to prevent DC wires from being
loosened.
3. Power 1 and Power 2 support power redundancy and polarity
reverse protection functions.
4. Positive and negative power system inputs are both accepted,
but Power 1 and Power 2 must apply the same mode.
3. Mount the Switch to 19’’ rack
3.1 Attach the brackets to the device by using the screws provided in the Rack Mount kit.
3.2 Mount the device in the 19’ rack by using four rack-mounting screws provided by the
rack manufacturer.
3.3 When installing multiple switches, mount
them in the rack one below the other.
4. Stacking the Switches: A total of 8 switches can be put into a single stack. Stacked
JetNet 6524G Switches can be assigned a single IP address using the switch's
management software. The stack can then be treated as a single manageable unit with one
IP address.
1. Make sure all switches in the stack are powered off.
2. Connect switches through the HighGig ports in the backplane.
3. Power on the switches.
4. The Link LED in the rear panel indicates the link status of the stacking port.
Note: Korenix provide the stacking cable for purchasement. When the volume of the
stack is under 4, the JNSC-CX405M-S, 50cm stacking cable is enough. When the volume
is above 4, additional one JNSC=CX401M-S, 100cm stacking cable is required for the
connection from the unit 1 to the last unit.
Note: Check if the rack environment
WHPSHUDWXUHFRQIRUPVWRWKHVSHFL¿HG
operating temperature range. Do not
place any equipment on top of the
switch and please properly grounded.
$IWHU\RXKDYHVXFFHVVIXOO\LQVWDOOHGWKH6ZLWFK\RXFDQFRQ¿JXUHWKH6ZLWFKPRQLWRU
the LED panel, and display statistics graphically using a Web browser, such as Netscape
Navigator (version 6.2 and higher) or Microsoft® Internet Explorer (version 5.0).
7KHGHIDXOW,3DGGUHVVEHIRUHFRQ¿JXULQJLV8VHU1DPHLVDGPLQQRGHIDXOW
password is requested.
$IWHUFRQ¿JXUHGWKHOD\HUYLWXDOLQWHUIDFHV\RXFDQDVVLJQSULPDU\,3DQGVHFRQG,3
addresses to the interface, this is known as default gateway of the lower hosts. The lower
hosts in each subnet can access the interface by the default gateway IP address.
The default IP address is only available in layer 2 mode, the layer 2 mode means there is
QRDQ\FRQ¿JXUHGOD\HUYLUWXDOLQWHUIDFH$IWHUFRQ¿JXUHGWKHOD\HUYLUWXDOLQWHUIDFHWKH
default IP address is changed to the assigned primary/second IP address of the interface.
NOTE: To access the Switch through a Web browser, the computer running the Web
browser must have IP-based network access to the Switch. It is not suggested multiple
user’s access to the web browser. The performance of web display would be affected.
Warning: Since the lower hosts under the layer 3 interface can access the switch by
default gateway IP address. Please remember to change the user name and password
LQ\RXU¿UVWORJLQ2WKHUZLVHWKHXVHUVFDQHDVLO\DFFHVVWKHPDQDJHPHQWLQWHUIDFHDQG
change the settings. It obeys the common security concern.
You can also connect a computer or terminal to the serial console port or use Telnet to
access the Switch. The command-line-driven interface provides complete access to all
switch management features.
Device Management
The system may be managed out-of-band through the console port on the rear panel or in-
band using Telnet, a Web Browser, or SNMP.
1. Web-based Management Interface
2. Command Line Console Interface Through the Serial Port or Telnet
You can manage the Switch with an SNMP-compatible console program. The Switch
supports SNMP version 1.0, version 2.0, and version 3.0. The SNMP agent decodes
the incoming SNMP messages and responds to requests with MIB objects stored in the
database. The SNMP agent updates the MIB objects to generate statistics The Switch
supports a comprehensive set of MIB extensions:
RFC1643 Ether-like MIB
RFC1493 Bridge
RFC 2819 RMON
RFC2233 Interface MIB
RFC2571 (SNMP Frameworks)
RFC2572 (Message Processing for SNMP)
RFC2573 (SNMP Applications)
RFC2576 (Coexistence between SNMPs)
RFC2618 (Radius-Auth-Client-MIB)
RFC2620 (Radius-Acc-Client-MIB)
RFC 1724 (RIPv2-MIB)
RFC 1850 (OSPF-MIB)
RFC 1850 (OSPF-TRAP-MIB)
RFC 2787 (VRRP-MIB)
RFC 3289 - DIFFSERV-DSCP-TC
RFC 3289 - DIFFSERV-MIB
QOS-DIFFSERV-EXTENSIONS-MIB
QOS-DIFFSERV-PRIVATE-MIB
RFC2674 802.1p
RFC 2932 (IPMROUTE-MIB)
ROUTING-MIB
MGMD-MIB
RFC 2934 PIM-MIB
DVMRP-STD-MIB
IANA-RTPROTO-MIB
MULTICAST-MIB
Korenix Customer Service
KoreCARE is Korenix Technology’s global service center, where our professional staffs are
ready to answer your questions at any time.
Email address of Korenix Global Service Center: [email protected]
3. SNMP-Based Management
Ᾰ䘦
JetNet 6524Gᱥжⅴ19㤧ሮᵰᷬᕅޞॹݼL3㖇㇗ශӚᦘᵰθ䞃༽24Ѡ10/100/1000 Base-TX
ㄥਙૂ4ѠॹݼSFP comboㄥਙθᨆבᴶཝौ੔੆䠅ૂ⚫⍱ᙝθ┗䏩儎ㄥਙᇼᓜૂ儎䙕䘔㓵
䴶≸Ⱦֵ⭞ḽ䞃฼Ḿ㓵㔼θᴶཐਥੂᰬሼ8ਦ䇴༽฼ਖᡆжѠঋIP䇴༽θ䙐䗽ޞਂᐛ฼Ḿ㓵㔼
ӈ䘔θਥᨆב儎䗴40G㜂ᶵᑜᇳȾ⚫⍱Ⲻ᧛ਙ䇴䇗θֵ∅жѠJetNet 6524G฼Ḿਥᨆב192Ѡ
ॹݼㄥਙૂ384GᑜᇳθԛࡑᔰᲰ㜳ཝශ㖇㔒Ⱦ
䲚Ҽ90-264VACב⭫Ⲻ儎ুӚ⍷⡾ᵢ(JetNet 6524G)θKorenix䘎ᨆב᭥ᤷ24V48Vב⭫Ⲻᰖ
伄᡽քু⴪⍷⡾ᵢ(JetNet 6524GDC)θᐛ֒⑟ᓜ㤹പ: -40~65đ䘸⭞ᚬࣙⲺᐛѐ⧥ູȾ
1. ᢉᔶऻ㻻Ỷḛ䞃Ԭ
ᵰᷬᕅ㖇㇗ශӚᦘᵰ
RS-232 DB᧝࡬㓵㔼
ᵰᷬᆿ㻻䞃Ԭ
⭫Ⓠ㓵(דᦤуੂളᇬ㿺㤹)
QIGᘡ䙕ᆿ㻻ੇሲ
2. ⮂䶘ԁ㔃
⺢Ԭᆿ㻻
CH
2.1ࢃᶵ㓺ԬφӚᦘᵰࢃ䶘ᶵऻ੡φLED᤽⽰⚥Ƚԛའ㖇᧛ਙȽ഑ѠSFP(Mini-GBIC)
ComboਙȾ
LEDᱴ⽰㠠Ỷ/⭫ⓆȽ⣬ᘷδStacking MasterεૂㄥਙLink/ActiveȾ
2.2 LED᤽⽰φࢃ䶘ᶵⲺLEDऻᤢθ⭫ⓆȽConsoleૂԛའ㖇᧛ਙLink/Aact statusȾ24ѠLED
δ∅Ѡㄥਙ2Ѡ᤽⽰⚥ε᤽⽰䘔᧛Ƚ◶⍱⣬ᘷૂㄥਙ䙕⦽Ⱦ8ѠLED฼ਖ᤽⽰⚥θδ∅Ѡ฼ਖ
4Ѡε᤽⽰⣬ᘷθRXȽTXȽњѠ฼ਖ⁗ඍҁ䰪䘔᧛Ⱦ
2.3 ੄ᶵ㓺ԬφӚᦘᵰ੄䶘ᶵऻᤢφ⭫ⓆACDC䘔᧛ȽRS-232᧝࡬ਙȽњѠ฼ḾਙȾ
1ѠRS232 DCE᧝࡬ㄥਙθᯯ׵䙐䗽᧝࡬㓵㔼䘔᧛Ӛᦘᵰθ൞PCр䘆㺂䎻㓝㓾ㄥθ঩ਥⲱᖋ
Ӛᦘᵰᒬᇂᡆࣕ㜳䇴㖤Ⱦ唎䇚ⲺѨਙ৸ᮦѰφ115,200, N, 8, 1.
21 22 23 24
21
22
23
24
Module
Link/Act
181614 20 22 24
171513 19 21 23
Link/Act
6428 10 12
5317 91 1
Orange
Green
Off
: 1Gbps
: 100Mbps
: 10Mbps
Power/
Self-test
Status
24G Rackmount Layer3
Managed Ethernet Switch
6524G
ᡭਥሼ⭫㝇ᡌ㓾ㄥ䘔᧛ࡦѨ㺂᧝࡬ㄥਙθᡌ䙐䗽Telnetᯯᕅᇔ⧦ળԚ㺂ⲱᖋȾળԚ㺂⮂䶘
ᨆבޞ䶘ⲺӚᦘᵰࣕ㜳㇗⨼Ⱦ
2. 䙐䗽ѨਙᡌTelnet䘑㺂ળԚ㺂䇵䰤
⭞ᡭਥԛֵ⭞SNMP᧝࡬ぁᓅ㇗⨼ӚᦘᵰȾӚᦘᵰ᭥ᤷSNMP version 1.0θversion 2.0
version 3.0ȾSNMP agent䀙⸷ՖޛⲺSNMPؗᚥθਃ侾MIBሯ䊗ٲᆎޛؗᚥᓉȾSNMP
agentᴪ᯦MIBሯ䊗⭕ᡆ㔕䇗ᮦᦤȾӚᦘᵰ᭥ᤷޞ䶘ⲺMIBᢟኋφ
RFC1643 Ether-like MIB
RFC1493 Bridge
RFC 2819 RMON
RFC2233 Interface MIB
RFC2571 (SNMP Frameworks)
RFC2572 (Message Processing for SNMP)
RFC2573 (SNMP Applications)
RFC2576 (Coexistence between SNMPs)
RFC2618 (Radius-Auth-Client-MIB)
RFC2620 (Radius-Acc-Client-MIB)
RFC 1724 (RIPv2-MIB)
RFC 1850 (OSPF-MIB)
RFC 1850 (OSPF-TRAP-MIB)
RFC 2787 (VRRP-MIB)
RFC 3289 - DIFFSERV-DSCP-TC
RFC 3289 - DIFFSERV-MIB
QOS-DIFFSERV-EXTENSIONS-MIB
QOS-DIFFSERV-PRIVATE-MIB
RFC2674 802.1p
RFC 2932 (IPMROUTE-MIB)
ROUTING-MIB
MGMD-MIB
RFC 2934 PIM-MIB
DVMRP-STD-MIB
IANA-RTPROTO-MIB
MULTICAST-MIB
Korenixᇘᡭᵃࣗ
KoreCAREᱥ〇⍑⨼ᙓ〇ᢶޞ⨹ᵃࣗѣᗹθᡇԢщѐⲺᢶᵥӰ઎䳅ᰬ߼༽䀙ㆊᛞⲺ⯇䰤Ⱦ
〇⍑⨼ᙓޞ⨹ᇘᵃѣᗹEmail൦൶Ѱ: [email protected]
3. SNMP㇗⨼
RU
ȼɜɟɞɟɧɢɟ
-HW1HW*ɹɜɥɹɟɬɫɹɞɸɣɦɨɜɵɣɝɢɝɚɛɢɬɧɵɦɧɚɪɚɳɢɜɚɟɦɵɦɭɩɪɚɜɥɹɟɦɵɦ
ɤɨɦɦɭɬɚɬɨɪɨɦɝɨɭɪɨɜɧɹɨɫɧɚɳɟɧɧɵɦɩɨɪɬɚɦɢ%DVH7;ɢ
ɝɢɝɚɛɢɬɧɵɦɢɤɨɦɛɢɧɢɪɨɜɚɧɧɵɦɢɩɨɪɬɚɦɢ6)3ɨɛɟɫɩɟɱɢɜɚɸɳɢɯɦɚɤɫɢɦɭɦɩɪɨɩɭɫɤɧɨɣ
ɫɩɨɫɨɛɧɨɫɬɢɢɝɢɛɤɨɫɬɢɞɥɹɜɵɫɨɤɨɣɩɥɨɬɧɨɫɬɢɢɫɜɟɪɯɜɵɫɨɤɨɣɫɤɨɪɨɫɬɢɫɨɟɞɢɧɟɧɢɹ
ɉɪɢɫɬɟɤɢɪɨɜɚɧɢɢɤɚɛɟɥɹɫɬɟɤɚɦɢɞɨɟɞɢɧɢɰɦɨɝɭɬɛɵɬɶɫɨɛɪɚɧɧɵɟɜɦɟɫɬɟ
ɱɬɨɩɨɡɜɨɥɹɟɬɩɨɫɬɪɨɢɬɶɭɫɬɪɨɣɫɬɜɨɭɩɪɚɜɥɹɟɦɨɟɩɨɨɞɧɨɦɭ,3ɢɨɞɧɨɜɪɟɦɟɧɧɨ
ɨɛɟɫɩɟɱɢɜɚɸɳɟɟ*ɩɨɥɧɨɞɭɩɥɟɤɫɧɨɣɫɜɹɡɢɜɨɞɧɨɣɩɚɧɟɥɢȽɢɛɤɚɹɤɨɧɫɬɪɭɤɰɢɹ
-HW1HW*ɩɨɡɜɨɥɹɟɬɨɛɟɫɩɟɱɢɬɶɞɨɝɢɝɚɛɢɬɧɵɯɩɨɪɬɨɜɜɫɬɟɤɟɢɩɪɨɩɭɫɤɧɭɸ
ɫɩɨɫɨɛɧɨɫɬɶ*ɞɥɹɩɨɫɬɪɨɟɧɢɹɢɧɬɟɥɥɟɤɬɭɚɥɶɧɵɯɤɪɭɩɧɨɦɚɫɲɬɚɛɧɵɯɫɟɬɟɣ
ȼɞɨɩɨɥɧɟɧɢɟɧɚɨɫɧɨɜɟ-HW1HW*ɦɨɞɟɥɢ9$&.RUHQL[ɩɪɟɞɨɫɬɚɜɥɹɟɬɪɹɞ
-HW1HW*'&ɤɨɬɨɪɵɟɩɨɞɞɟɪɠɢɜɚɸɬȼɢɥɢȼɢɜɵɩɨɥɧɟɧɵɜɛɟɡɜɟɧɬɢɥɹɬɨɪɧɨɦ
ɤɨɪɩɭɫɟɫɲɢɪɨɤɢɦɞɢɚɩɚɡɨɧɨɦɪɚɛɨɱɢɯɬɟɦɩɟɪɚɬɭɪa
O
Cɞɥɹɬɹɠɟɥɵɯɭɫɥɨɜɢɣ
ɷɤɫɩɥɭɚɬɚɰɢɢ
ɉɪɢɜɫɤɪɵɬɢɢɤɨɪɨɛɤɢɜɵɨɛɧɚɪɭɠɢɬɟ
ɋɬɨɟɱɧɵɣɭɩɪɚɜɥɹɟɦɵɣɤɨɦɦɭɬɚɬɨɪ-HW1HW*
56'%1XOO0RGHPɤɚɛɟɥɶɩɪɨɝɪɚɦɦɢɪɨɜɚɧɢɹ
Ʉɨɦɩɥɟɤɬɤɪɟɩɟɠɚ
ɒɧɭɪɩɢɬɚɧɢɹɬɢɩɡɚɜɢɫɢɬɨɬɫɬɪɚɧɵ-HW1HW*'&ɧɟ
ɤɨɦɩɥɟɤɬɭɟɬɫɹɲɧɭɪɨɦɩɢɬɚɧɢɹ
Ɋɭɤɨɜɨɞɫɬɜɨɩɨɭɫɬɚɧɨɜɤɟ
ȼɜɟɞɟɧɢɟɜɢɧɬɟɪɮɟɣɫ
Ʉɨɦɩɨɧɨɜɤɚɩɟɪɟɞɧɟɣɩɚɧɟɥɟɣɇɚɩɟɪɟɞɧɟɣɩɚɧɟɥɢɧɚɯɨɞɹɬɫɹɢɧɞɢɤɚɬɨɪɵ
ɩɨɪɬɵɝɢɝɚɛɢɬɧɨɝɨ(WKHUQHWɢɤɨɦɛɢɧɢɪɨɜɚɧɧɵɯɩɨɪɬɚ6)30LQL*%,&
ɋɜɟɬɨɞɢɨɞɧɵɟɢɧɞɢɤɚɬɨɪɵɨɬɨɛɪɚɠɚɸɬɫɨɫɬɨɹɧɢɟɫɚɦɨɞɢɚɝɧɨɫɬɢɤɢɩɢɬɚɧɢɹ
ɋɨɫɬɨɹɧɢɟɫɬɷɤɚɢɋɨɟɞɢɧɟɧɢɟȺɤɬɢɜɧɨɫɬɶɩɨɪɬɨɜ
ɋɜɟɬɨɞɢɨɞɧɵɟɢɧɞɢɤɚɬɨɪɵɋɜɟɬɨɞɢɨɞɧɵɟɢɧɞɢɤɚɬɨɪɵɧɚɩɟɪɟɞɧɟɣɩɚɧɟɥɢ
ɜɤɥɸɱɚɸɬɜɫɟɛɹɉɢɬɚɧɢɟɤɨɧɫɨɥɶɢɫɨɫɬɨɹɧɢɟɋɨɟɞɢɧɟɧɢɟȺɤɬɢɜɧɨɫɬɶɩɨɪɬɨɜ
(WKHUQHWɩɨɪɬɨɜɫɜɟɬɨɞɢɨɞɚɞɥɹɤɚɠɞɨɝɨɩɨɪɬɚɩɨɤɚɡɵɜɚɟɬɫɨɟɞɢɧɟɧɢɟɫɬɚɬɭɫ
ɚɤɬɢɜɧɨɫɬɢɢɫɤɨɪɨɫɬɶɫɨɟɞɢɧɟɧɢɹɞɥɹɤɚɠɞɨɝɨɩɨɪɬɚ
ɍɫɬɚɧɨɜɤɚ-HW1HW*
21 22 23 24
21
22
23
24
Module
Link/Act
181614 20 22 24
171513 19 21 23
Link/Act
6428 10 12
5317 91 1
Orange
Green
Off
: 1Gbps
: 100Mbps
: 10Mbps
Power/
Self-test
Status
24G Rackmount Layer3
Managed Ethernet Switch
6524G
Ɋɚɡɴɟɦɩɢɬɚɧɢɹɩɟɪɟɦɟɧɧɨɝɨɬɨɤɚɹɜɥɹɟɬɫɹɫɬɚɧɞɚɪɬɧɵɦɤɨɬɨɪɵɣɩɨɞɞɟɪɠɢɜɚɟɬ
ɫɟɬɟɜɨɣɲɧɭɪɉɨɞɤɥɸɱɢɬɟɝɧɟɡɞɨɜɨɣɪɚɡɴɟɦɩɪɢɥɚɝɚɟɦɨɝɨɤɚɛɟɥɹɩɢɬɚɧɢɹɤɷɬɨɦɭ
ɪɚɡɴɟɦɭɚɲɬɟɩɫɟɥɶɧɭɸɫɬɨɪɨɧɭɲɧɭɪɚɜɪɨɡɟɬɤɭɄɨɦɦɭɬɚɬɨɪɚɜɬɨɦɚɬɢɱɟɫɤɢ
ɧɚɫɬɪɚɢɜɚɟɬɫɹɩɨɦɨɳɧɨɫɬɢɤɥɸɛɨɦɭɧɚɩɪɹɠɟɧɢɹɩɢɬɚɧɢɹɜɞɢɚɩɚɡɨɧɟɨɬa
ȼɩɟɪɟɦɟɧɧɨɝɨɬɨɤɚɩɪɢaȽɰ
ɋɬɟɤɨɜɵɣɪɚɡɴɟɦɹɜɥɹɟɬɫɹɫɬɚɧɞɚɪɬɧɵɦɬɢɩɚ&;ɫ*ɩɨɥɧɨɞɭɩɥɟɤɫɧɨɣ
ɜɨɡɦɨɠɧɨɫɬɶɸɩɟɪɟɞɚɱɢȿɫɬɶɢɧɞɢɤɚɬɨɪɵɋɨɫɬɨɹɧɢɹ7[5[ɢɋɨɟɞɢɧɟɧɢɟɞɥɹ
ɢɧɞɢɤɚɰɢɢɫɨɫɬɨɹɧɢɹɫɬɟɤɨɜɨɝɨɩɨɪɬɚ
ɉɨɞɤɥɸɱɟɧɢɟɩɢɬɚɧɢɹɩɨɫɬɨɹɧɧɨɝɨɬɨɤɚɤ-HW1HW*'&
ɋɥɟɞɭɣɬɟɢɧɫɬɪɭɤɰɢɢɧɚɩɢɫɚɧɧɨɣɧɢɠɟɱɬɨɛɵɩɨɞɤɥɸɱɢɬɶɪɟɡɟɪɜɢɪɨɜɚɧɧɨɟ
ɩɢɬɚɧɢɟɤ-HW1HW*ɉɨɞɞɟɪɠɢɜɚɟɬɞɢɚɩɚɡɨɧɧɚɩɪɹɠɟɧɢɣȼ9'&ɢɥɢ
ȼ9ɩɢɬɚɧɢɹɩɨɫɬɨɹɧɧɨɝɨɬɨɤɚȼɵɛɟɪɢɬɟɜɯɨɞɧɭɸɦɨɳɧɨɫɬɶɜɫɨɨɬɜɟɬɫɬɜɢɢ
ɫɦɨɞɟɥɶɸ
100-240V~, 50/60HZ
Console
115200,N,8,1
1
21
2
10G / Stack
Status
RX
TX
Link
ȼɫɬɚɜɶɬɟɩɪɨɜɨɞɚɨɬɪɢɰɚɬɟɥɶɧɨɣɢɩɨɥɨɠɢɬɟɥɶɧɨɣ
ɩɨɥɹɪɧɨɫɬɢɜɫɨɨɬɜɟɬɫɬɜɭɸɳɢɟɤɨɧɬɚɤɬɵ9ɢ9ɜɢɧɬɨɜɨɝɨ
ɤɥɟɦɧɢɤɚ
Ɂɚɬɹɧɭɬɶɜɢɧɬɵɤɥɟɦɧɢɤɚɱɬɨɛɵɩɪɟɞɨɬɜɪɚɬɢɬɶɜɵɩɚɞɟɧɢɹ
ɩɪɨɜɨɞɨɜɜɫɥɭɱɚɟɢɯɨɫɥɚɛɥɟɧɢɹ
ɉɢɬɚɧɢɟɢɉɢɬɚɧɢɟɩɨɞɞɟɪɠɢɜɚɸɬɪɟɡɟɪɜɢɪɨɜɚɧɢɟɨɞɢɧ
ɨɬɤɚɡɵɜɚɟɬɞɪɭɝɨɣɩɨɞɯɜɚɬɵɜɚɟɬ
ɉɨɥɨɠɢɬɟɥɶɧɵɟɢɨɬɪɢɰɚɬɟɥɶɧɵɟɩɪɨɜɨɞɚɨɬɢɫɬɨɱɧɢɤɚ
ɩɢɬɚɧɢɹɢɫɩɨɥɶɡɭɸɬɫɹɤɚɤɨɛɵɱɧɨɧɨɉɢɬɚɧɢɟɢɉɢɬɚɧɢɟ
ɞɨɥɠɧɵɛɵɬɶɢɞɟɧɬɢɱɧɵɛɵɬɶɜɨɞɧɨɦɪɟɠɢɦɟ
ȼ5HDOɩɚɧɟɥɢɫɜɟɬɨɞɢɨɞɵɨɬɨɛɪɚɠɚɸɬɫɨɫɬɨɹɧɢɟɫɬɟɤɚȽɪɭɩɩɚɢɡɩɨɪɬɨɜɞɥɹ
ɤɚɠɞɨɣɫɬɟɤɨɜɨɝɨɩɨɪɬɚɭɤɚɡɵɜɚɟɬɫɬɚɬɭɫ5;7;ɫɨɟɞɢɧɟɧɢɹɫɬɟɤɨɜɵɯɩɨɪɬɨɜ
Ɉɩɢɫɚɧɢɟɡɚɞɧɟɣɩɚɧɟɥɢɇɚɡɚɞɧɟɣɩɚɧɟɥɢɤɨɦɦɭɬɚɬɨɪɚɪɚɫɩɨɥɨɠɟɧɪɚɡɴɟɦ
ɩɢɬɚɧɢɹɩɟɪɟɦɟɧɧɨɝɨɬɨɤɚɢɥɢɪɚɡɴɟɦɩɢɬɚɧɢɹɩɨɫɬɨɹɧɧɨɝɨɬɨɤɚɤɨɧɫɨɥɶɧɵɣɩɨɪɬ
56ɪɚɡɴɟɦɵɞɜɭɯɫɬɟɤɨɜɵɯɩɨɪɬɨɜɄɨɧɫɨɥɶɧɵɣɩɨɪɬ56'&(ɩɪɟɞɧɚɡɧɚɱɟɧ
ɞɥɹɧɚɫɬɪɨɣɤɢɢɭɩɪɚɜɥɟɧɢɹɤɨɦɦɭɬɚɬɨɪɨɦɩɪɢɩɨɦɨɳɢɬɟɪɦɢɧɚɥɚɢɥɢɉɄɫ
ɩɨɦɨɳɶɸɩɪɨɝɪɚɦɦɵɷɦɭɥɹɰɢɢɬɟɪɦɢɧɚɥɚɋɤɨɪɨɫɬɶɩɟɪɟɞɚɱɢɞɚɧɧɵɯɩɨɭɦɨɥɱɚɧɢɸ
115200, N, 8, 1.
ȼɵɦɨɠɟɬɟɭɩɪɚɜɥɹɬɶɤɨɦɦɭɬɚɬɨɪɨɦɫ6103ɫɨɜɦɟɫɬɢɦɨɣɩɪɨɝɪɚɦɦɵɄɨɦɦɭɬɚɬɨɪ
ɩɨɞɞɟɪɠɢɜɚɟɬ6103ɜɟɪɫɢɢɜɟɪɫɢɢɢɜɟɪɫɢɢ6103ɚɝɟɧɬɞɟɤɨɞɢɪɭɟɬ
ɜɯɨɞɹɳɢɟɫɨɨɛɳɟɧɢɹ6103ɢɨɬɜɟɱɚɟɬɧɚɡɚɩɪɨɫɵɫɨɛɴɟɤɬɚɦɢ0,%ɯɪɚɧɹɳɢɦɢɫɹ
ɜɛɚɡɟɞɚɧɧɵɯ6103ɚɝɟɧɬɨɛɧɨɜɥɹɟɬɨɛɴɟɤɬɵ0,%ɞɥɹɫɨɡɞɚɧɢɹɫɬɚɬɢɫɬɢɤɢ
Ʉɨɦɦɭɬɚɬɨɪɩɨɞɞɟɪɠɢɜɚɟɬɩɨɥɧɵɣɧɚɛɨɪɪɚɫɲɢɪɟɧɢɣ0,%
RFC1643 Ether-like MIB
RFC1493 Bridge
RFC 2819 RMON
RFC2233 Interface MIB
RFC2571 (SNMP Frameworks)
RFC2572 (Message Processing for SNMP)
RFC2573 (SNMP Applications)
RFC2576 (Coexistence between SNMPs)
RFC2618 (Radius-Auth-Client-MIB)
RFC2620 (Radius-Acc-Client-MIB)
RFC 1724 (RIPv2-MIB)
RFC 1850 (OSPF-MIB)
RFC 1850 (OSPF-TRAP-MIB)
RFC 2787 (VRRP-MIB)
RFC 3289 - DIFFSERV-DSCP-TC
RFC 3289 - DIFFSERV-MIB
QOS-DIFFSERV-EXTENSIONS-MIB
QOS-DIFFSERV-PRIVATE-MIB
RFC2674 802.1p
RFC 2932 (IPMROUTE-MIB)
ROUTING-MIB
MGMD-MIB
RFC 2934 PIM-MIB
DVMRP-STD-MIB
IANA-RTPROTO-MIB
MULTICAST-MIB
ɋɟɪɜɢɫɧɚɹɫɥɭɠɛɚ.RUHQL[
.RUH&$5(ɷɬɨɝɥɨɛɚɥɶɧɵɣɫɟɪɜɢɫɧɵɣɰɟɧɬɪ.RUHQL[ɝɞɟɧɚɲɢɤɜɚɥɢɮɢɰɢɪɨɜɚɧɧɵɟ
ɫɨɬɪɭɞɧɢɤɢɝɨɬɨɜɵɨɬɜɟɬɢɬɶɧɚɜɚɲɢɜɨɩɪɨɫɵɜɥɸɛɨɟɜɪɟɦɹ
Ⱥɞɪɟɫɷɥɟɤɬɪɨɧɧɨɣɩɨɱɬɵɝɥɨɛɚɥɶɧɨɝɨɫɟɪɜɢɫɰɟɧɬɪɚ.RUHQL[.RUH&$5(#NRUHQL[FRP
ɍɩɪɚɜɥɟɧɢɟɧɚɨɫɧɨɜɟ6103
ȼɵɬɚɤɠɟɦɨɠɟɬɟɩɨɞɤɥɸɱɢɬɶɤɨɦɩɶɸɬɟɪɢɥɢɬɟɪɦɢɧɚɥɤɩɨɫɥɟɞɨɜɚɬɟɥɶɧɨɦɭɩɨɪɬɭ
ɤɨɧɫɨɥɢɢɥɢɢɫɩɨɥɶɡɨɜɚɬɶ7HOQHWɞɥɹɞɨɫɬɭɩɚɤɤɨɦɦɭɬɚɬɨɪɭɄɨɦɚɧɞɧɚɹɫɬɪɨɤɚ
ɨɛɟɫɩɟɱɢɜɚɟɬɩɨɥɧɵɣɞɨɫɬɭɩɤɨɜɫɟɦɮɭɧɤɰɢɹɦɭɩɪɚɜɥɟɧɢɹɤɨɦɦɭɬɚɬɨɪɚ
ɂɧɬɟɪɮɟɣɫɤɨɦɚɧɞɧɨɣɫɬɪɨɤɢɤɨɧɫɨɥɢɢɥɢ7HOQHWɩɪɢɫɨɟɞɢɧɟɧɢɟɱɟɪɟɡ
ɩɨɫɥɟɞɨɜɚɬɟɥɶɧɵɣɩɨɪɬ
Patent No. (Taiwan):
Granted Invention: I 313547
Granted Invention: I 321415
Granted Invention: I 344766
Granted Invention: I 346480
Granted Invention: I 356616
Granted Invention: I 364684
Granted Invention: I 376118
Granted Invention: I 393317
Granted Invention: I 398066
Granted Invention: I 398125
Granted Invention: I 459757
Utility Model: M 339841
Utility Model: M 339840
Ѯᢊடց
ี݂಑ I 313547
ี݂಑ I 321415
ี݂಑ I 344766
ี݂಑ I 346480
ี݂಑ I 356616
ี݂಑ I 364684
ี݂಑ I 376118
ี݂಑ I 393317
ี݂಑ I 398066
ี݂಑ I 398125
ี݂಑ I 459757 !!
ཱི࠮಑ M 339841
ཱི࠮಑ M 339840
Tel:+886-2-89111000
Fax:+886-2-29123328
Business service:[email protected]
Customer service:[email protected]
CPQ000N6524000
/