Multicomponent Force Plate for Biomechanics Type 9281E…
Page 2 9281E_002-463e-10.08
Content
1. Introduction ................................................................................................................................... 4
2. Important Information.................................................................................................................... 5
2.1 For your Safety..................................................................................................................... 5
2.2 ä-Conformity.....................................................................................................................6
2.3 How to Treat the Instrument................................................................................................ 6
2.3.1 With External Amplifier (Type 9281E) .................................................................................. 6
2.4 Hints for Using the Operating Instructions ........................................................................... 7
2.5 What Happens After Modifications? .................................................................................... 7
2.6 Disposal Instructions for Electrical and Electronic Equipment ................................................ 7
3. General Description of the Instrument ...........................................................................................8
3.1 What does a Multicomponent Force Plate Do? .................................................................... 8
3.2 Two Different Versions......................................................................................................... 9
3.3 Application Examples ........................................................................................................... 9
3.4 Functional Principle .............................................................................................................. 9
3.5 Design of the Force Plate ................................................................................................... 11
4. Assembly, Installation and Putting Into Operation...................................................................... 12
4.1 Important Remarks............................................................................................................. 12
4.2 Basic Circuitry and Cabling of the Measuring System ......................................................... 13
4.3 Connections with External Amplifier (Type 9281E)............................................................. 14
4.3.1 Output Connector of Force Plate Type 9281E.................................................................... 14
4.4 Connections with Built-In Amplifier (Type 9281EA) ........................................................... 15
4.4.1 Output Connector of Force Plate Type 9281EA (with Built-In Amplifier)............................ 16
4.4.2 Cable Type 1759A... .......................................................................................................... 17
4.4.3 Digital Control.................................................................................................................... 18
5. Operation..................................................................................................................................... 19
5.1 Range Selection.................................................................................................................. 19
5.2 Operate/Reset ...................................................................................................................19
5.2.1 Balance (Posturography) .................................................................................................... 20
5.3 Time Constant.................................................................................................................... 20
5.4 Usable Frequency Range.................................................................................................... 20
5.5 Temperature Influences...................................................................................................... 21
5.6 Polarity of the Measuring Signal......................................................................................... 21
5.6.1 x- and y-Directions.............................................................................................................21
5.6.2 z-Direction ......................................................................................................................... 21
5.7 Surface Pressure ................................................................................................................. 22
6. Maintenance ................................................................................................................................ 23
6.1 Recalibration of the Instrument .......................................................................................... 23
6.2 Weekly Function Check...................................................................................................... 23
6.2.1 Drift Check......................................................................................................................... 23
6.2.2 Check Gap Around Force Plate........................................................................................... 24
6.2.3 System Check..................................................................................................................... 24
6.2.4 Setup Parameters ............................................................................................................... 24
6.3 Regular Calibration of the Charge Amplifier ....................................................................... 25