Humandata ACM-110-50 User manual

Type
User manual

This manual is also suitable for

HuMANDATA LTD.
MAX10 FPGA Board
ACM-110 Rev2
User’s Manual
Ver. 2.0
Table of Contents
Revision History .............................................................................................. 1
Introduction .................................................................................................... 1
1. Specifications ..................................................................................................... 2
2. Overview ............................................................................................................ 3
2.1. Name of Parts .......................................................................................................3
2.2. Block Diagram ......................................................................................................4
2.3. Power Supply ........................................................................................................4
2.4. Clock ......................................................................................................................5
2.5. Setting Switch ......................................................................................................5
2.6. User Switch ..........................................................................................................5
2.7. User LED ..............................................................................................................5
2.8. Debug I/F ..............................................................................................................5
2.9. A/D Conversion Input ..........................................................................................6
2.10. JTAG Connector .................................................................................................7
3. FPGA Configuration ........................................................................................... 8
4. Configuration Device Programming ................................................................... 8
4.1. Generating pof file ...............................................................................................8
4.2. Access to built-in Configuration Device ..............................................................8
5. FPGA Pin Assignment ........................................................................................ 9
6. Additional Documentation and User Support ................................................... 10
Precautions
Do Not
1. This product uses ordinary off-the-shelf electronic components, and is therefore inappropriate for use in
applications that require special quality or reliability and are expected to protect human lives or prevent
accidents, such as safety mechanisms in fields including space, aeronautics, medicine, and nuclear
power.
2. Do not be used underwater or in high-humidity environments.
3. Do not be used in the presence of corrosive gases, combustible gases, or other flammable gases.
4. Do not turn on power when circuit board surface is in contact with other metal.
5. Do not apply voltage higher than rated voltage.
Attention
6. This manual may be revised in the future without notice owing to improvements.
7. All efforts have been made to produce the best manual possible, but if users notice an error or other
problem, we ask that they notify us.
8. Item 7 notwithstanding, HuMANDATA cannot be held liable for the consequences arising from use of
this product.
9. HuMANDATA cannot be held liable for consequences arising from using this product in a way different
from the uses described herein, or from uses not shown herein.
10. This manual, circuit diagrams, sample circuits, and other content may not be copied, reproduced, or
distributed without permission.
11. If the product emits smoke, catches fire, or becomes unusually hot, cut the power immediately.
12. Be careful of static electricity.
13. This product may be subject to the export restrictions of Japan, the United States, or other countries.
Purchasers are responsible for properly observing export restrictions.
14. HuMANDATA firmly refuses to export (including reexporting) products to countries or regions subject to
export restrictions.
Product Warranty and Scope of Support
1. HuMANDATA guarantees that its products can be assembled as shown in published circuit diagrams and other design documents.
There may be differences between actual components or their prescribed quantities and model numbers and those shown in circuit
diagrams.
2. Except for the guarantee in item 1, above, no guarantees whatsoever are made. When assembling the product as shown in a circuit
diagram is impossible, and the problem can be solved by revising the diagram, HuMANDATA will revise the diagram. When a problem
can be solved only by replacing components or modifying the product, HuMANDATA will take back the product to replace it with a
properly functioning product.
3. In case item 2, above, HuMANDATA guarantee its products for a period of 60 days from the date of shipping.
4. If the problem is minor, HuMANDATA will sometimes describe how to make the revision or modification, and ask the customer to
solve the problem.
5. HuMANDATA will determine how to honor the warranty, as through repair, replacement, return, or other action. The customer cannot
specify what action to take.
6. FPGAs and other components used in products sometimes have characteristic defects. Returns and replacements are not possible
even if such defects are discovered, whether before or after purchase.
7. HuMANDATA shall not be obligated to inform customers about defects in the main components used in products.
8. HuMANDATA shall not be obligated to provide support for products, or to provide support for the software of other companies needed
to use HuMANDATA products.
9. Published documentation shall be limited to that published by HuMANDATA at the time of product purchase, and HuMANDATA shall
not be obligated to provide any other documentation.
10. When repairs or replacements are provided under warranty in Japan, purchaser shall pay shipping charges for shipping to
HuMANDATA, and HuMANDATA shall pay shipping charges for shipping to purchaser.
11. When shipping from outside of Japan, purchaser shall pay all expenses including shipping charges and taxes.
12. Under whatever circumstances, HuMANDATA shall provide support for its products for a maximum of one year after shipping from
factory.
13. The Warranty is not applicable and support ends in the event of fire, storm and flood damage, earthquakes, lightning strikes, and
other natural disasters, as well as conflict or other occurrences.
14. Purchaser is assumed to have read and understood all the above when purchasing a HuMANDATA product.
Limitation of Liability
1. Purchasers assume all liability associated with the use of this product.
2. HuMANDATA assumes no liability whatsoever for any direct, indirect, special, incidental, or consequential damages arising from the
use of this product, even if HuMANDATA has been advised of the possibility of such damage, whether legal or in tort.
3. At the time this product is purchased, items 1 and 2 above shall be deemed to have been confirmed by purchaser.
Trademarks and Other Considerations
1. This manual uses various companies’ trademarks in places.
2. HuMANDATA is this company’s registered trademark.
HuMANDATA’s Philosophy
1. HuMANDATA endeavors to raise product quality. We continually make detailed improvements and adjustments that are not shown
in circuit diagrams.
2. HuMANDATA actively publishes, on the Web and in other ways, information considered useful to customers. Examples would be
how to use FPGAs and how to use development tools.
3. HuMANDATA makes efforts for the long-term provision of products and for continuing their long-term support.
4. Instead of concealing small product problems and documentation errors, HuMANDATA makes them public.
5. HuMANDATA abides by Japanese law and its spirit. We make no transactions with purchasers who commit illegal acts.
ACM-110 v2.0 1
Revision History
Date
Revision
Description
May 12, 2022 v2.0 Revised: Product Revision to Rev2
Introduction
Thank you for purchasing our product ACM-110 series.
This is an evaluation board equipped with an Intel MAX10, power, reset, and clock
circuit.
It provides you with very convenient and easy-to-use development environment.
ACM-110 v2.0 2
1. Specifications
Model Name
ACM-110-08
ACM-110-16
ACM-110-25
ACM-110-40
ACM-110-50
FPGA
10M08DAF
484C8G
10M16DAF
484C8G
10M25DAF
484C8G
10M40DAF
484C8G
10M50DAF
484C8G
Power Input
DC 3.3 [V]
User I/Os
128 (CNA: 64, CNB: 64)
Config. Device
Integrated
MRAM
MR2A16AMA35 (Everspin, 4Mbit)
On-Board Clock
30MHz (External inputs are available)
A/D Input Channel
9 (parallel with user I/O)
A/D Reference
on-board 2.5 [V]
User LED
2
User Switch
2 (Push x 1, DIP x1)
Power-On Reset
240 [ms] typ. (Configuration Reset Signal)
User I/O Connector
FX10A-80P/8-SV1 (Hirose) x 2
PCB
8 Layer FR-4 t1.6 [mm] Immersion gold
JTAG Connector
DIL 10-pin socket, 2.54 [mm] pitch
Status LEDs
Power (red), Done (blue)
Dimensions
1.693" x 2.126" (43 x 54 [mm])
Weight
17 [g] typ.
Accessories
DIL 10 long pin header (mounted) x 1
FX10A-80S/8-SV (Hirose) x 2
RoHS Compliance
YES
ACM-110 v2.0 3
2. Overview
2.1. Name of Parts
Component Side
Solder Side
MRAM
User SW
Setting SW
DONE LED
JTAG
Power LED
Filters for A/D
On-board Clock
User I/Os (CNA)
User I/Os (CNB)
User LEDs
User SW
Debug I/F
ACM-110 v2.0 4
2.2. Block Diagram
2.3. Power Supply
This board operates from single DC 3.3 V power supply from the CNA. External
power supply should be sufficient and stabilized. Please do not apply over 3.3V
voltage. Internally required 2.5[V] and 1.2[V] are generated by on-board voltage
regulators.
Power supply for VIO(B) can be input from CNB.
For more details, please refer to the circuit schematics and the FPGA data sheet.
MAX 10
10M08DAF484C8G
10M16DAF484C8G
10M25DAF484C8G
10M40DAF484C8G
10M50DAF484C8G
DONE LED User LED
Power LED (3.3V)
Power Circuit
2.5V, 1.2V
User I/Os CNA
64
ACM-110 Rev.A
User I/Os CNB
64
V I O(B) input
3 .3 V input
Oscillator
30 MHz
User Switch
( Push x1, DIP x1)
2
2
MRAM
( 4 M bit)
JTAG B u ffe r 9A/D I/F
ACM-110 v2.0 5
2.4. Clock
An oscillator, 30 MHz (U2), is equipped as on-board clock. External clock can be
input from user I/O connectors.
For more details, please refer to the circuit schematics.
2.5. Setting Switch
MAX10 can store two configuration images in its integrated flash memory.
You can select which image should be used when it is powered up by using
CONFIG_SEL” signal.
Please refer to the Intel’s configuration user guide for more details.
SW1
1 2
Net Label
CONFIG_SEL
ASW
Function
Select Config. Image
User
CONFIG_SEL
Image
ON (Low)
Image 0
OFF (High)
Image 1
2.6. User Switch
You can use SW1[2] and SW2 for general purpose. They are pulled
up, so you can input low level signal to the FPGA when you push
them.
2.7. User LED
You can use L2 and L3 for general purpose. They are active low.
2.8. Debug I/F
These are pads for serial communication. They are connected directly to FPGA
through serial resistance.
ACM-110 v2.0 6
2.9. A/D Conversion Input
A/D conversion input pins and user I/O pins use common connector pins, and they are
internally connected in parallel.
When you use AD conversion function, user I/O pins must be set to input or high-
impedance.
Connector A/D Input Paralleled user I/O
Net Label FPGA pin Net Label FPGAPin
CNA[30]
ADIN8
K6
IOA38
A2
CNA[32] ADIN7 K5 IOA39 A3
CNA[34] ADIN6 H3 IOA40 A4
CNA[36]
ADIN5
J4
IOA41
A5
CNA[38]
ADIN4
J9
IOA42
A6
CNA[40] ADIN3 J8 IOA43 B7
CNA[42]
ADIN2
F4
IOA44
A7
CNA[44] ADIN1 F5 IOA45 A8
CNA[46]
ANAIN1
G5
IOA46
B8
Input circuit of each channel
You can change input characteristics by setting R(R11- R19) and C(C6-C14).
Initially resistances are set to 100Ω and condensers are set to open.
ACM-110 v2.0 7
2.10. JTAG Connector
This connector is used to configure the FPGA and program the configuration device
in-system. Pin assignment is as follows.
CN1
Signal
Name
JTAG Pin
Signal
Name
TCK
1
2
GND
TDO 3 4 VCC
TMS
5
6
-
- 7 8 -
TDI
9
10
GND
Please use attached long pin header when you connect with Intel download cable to
the JTAG connector.
Please pay attention not to attach cables in reverse.
Notice
ACM-110 v2.0 8
3. FPGA Configuration
To configure the FPGA via JTAG directly, assign a sof
file to the FPGA detected by [Auto Detect].
If configuration is completed successfully, the DONE
LED will light up.
4. Configuration Device Programming
To download an FPGA configuration data to the built-in configuration device, pof
file is required.
To generate a pof file using Quartus II, please refer to the following steps.
4.1. Generating pof file
Start Quartus II, and open [File] menu and click [Convert Programming Files]
and set items as shown below.
Programming File Type : Programmer Object File (.pof)
Configuration Device : EPCE*
Mode : Internal Configuration
File name : any
1. Open [SOF Data] and Click [Add File…], then select the sof file.
2. Click [Generate]
4.2. Access to built-in Configuration Device
Please set configuration mode switch to AS mode.
Click [Add File] and select the jic file, then check [Program/Configure] and
click [Start].
1. Open [Add File…], then select the pof file.
2. Check [Program/Configure], then click [Start].
ACM-110 v2.0 9
5. FPGA Pin Assignment
FPGA Banks are grouped into connector classes and namedBank group A/B”.
Vccio of the Bank group A is fixed at V33A (3.3V). Vccio of the Bank group B is
variable and can be applied from the CNB connector.
For more details, please refer to the pin list file. You can download it from the
support page.
FPGA BANK Vccio Bank Group
1A
V25
-
1B
V25
-
2
V33A
A
3 VIO(B) B
4
VIO(B)
B
5 V33A A
6
VIO(B)
B
7 V33A A
8
V33A
A
ACM-110 v2.0 10
6. Additional Documentation and User Support
The following documents and other supports are available at
https://www.hdl.co.jp/en/spc/ACM/acm-110/
Circuit Schematic
Pin List
Outline Drawing
PCB drawing
Net List
and more.
MAX10 FPGA Board
ACM-110 Rev2
Users Manual
Ver. 2.0 ........................................... May 12, 2022
HuMANDATA LTD.
Address: 1-2-10-2 F, Nakahozumi, Ibaraki
Osaka, Japan
ZIP 567-0034
Tel: 81-72-620-2002 (Japanese)
Fax: 81-72-620-2003 (Japanese/English)
URL: https://www2.hdl.co.jp/en/ (Global)
https://www.hdl.co.jp (Japan)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Humandata ACM-110-50 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI