•Fitting: Gypsum
•Lamptype: D93 / D95 Including 1 x LED maximum 35W GX5.3 12V
•InputVoltage: 220V - 240V ~ 50/60Hz
OutputVoltage: 12V
•Protectionagainstelectricshock: Class 3. SELV does not require earthing.
•IPRating:20. Protected against solid foreign objects of 50mm Ø and greater. Not
protected against water.
• Commercial / domestic use
• Not suitable for outdoor use
•Maximumambienttemperaturerange: 20ºC - 40ºC
•Dimensions:
D93: (L)122mm x (W)122mm x (D)55mm
D95: (L)120mm x (W)120mm x (D)64mm
•Cut-out: D93 / D95 125 x 125
Before installation always ensure the power supply is turned off.
1. Cut a hole in the ceiling as per “cut out”.
2. Connect mains to the low voltage 230V on primary side, and the luminaire to the 12V
secondary side.
3.Insert downlight into ceiling hole ensuring the mains lead is not trapped.
4.Pushttingupwardstosnaprmlyintoposition,ushwithceiling.
5. Insert the lamp by locating the pin connection holes within the lamp
holder, gently pushing the lamp into the holder and twisting into place.
6. Attach shade
7. Reconnect power.
NOTE:Alwaysallowthelamptocoolsufcientlybeforechanging.
NOTE: Allow a minimum gap of about 200mm in height from downlight to ceiling / any materials
above the downlight and 50mm all around the sides of the downlight.
D93/D95-attachments:
Iftheexternalexiblecableorcordofthisluminaireisdamaged,itshouldbeexclusivelyreplaced
bythemanufacturerorhisserviceagentorasimilarqualiedpersoninordertoavoidahazard.To
ensure that you get maximum longevity and maximum use out of your luminaire, please observe
the following safety instructions.
Electrical products can cause death, injury, or damage to property. Installation of the luminaire
mustbecarriedoutbyaqualiedelectrician,inaccordancewithSANS10142.Oncompletion
ofinstallation,ensurethattheCerticateofComplianceisupdated.
•Beforeconnectingtheluminaire,ensurethatvoltageindicatedontheratinglabel
corresponds with the mains voltage in your home.
•Whenchangingthelamp,ensurethatthepoweristurnedoff.
•Ensurethatthecorrectlamptypeandwattageistted.
•Thisluminaireischeckedinfullforconformitytothequalitystandardsandsafetyrequirements.
•Themanufacturer/supplierisnotresponsibleforanydamageofpropertiesandpersons,
caused by the incorrect use or installation of the luminaire.
•Shouldyoubeunsureofhowtoinstallthisluminairecorrectly,pleaseconsultaprofessional
electrician or your supplier for assistance.
•Ensureallitems/components,threadsandscrewsaretightlysecured.
IMPORTANT:
•Tamperingwiththisluminaire,I.E.Usingsiliconsealersorincorrectcabling,willinvalidate
your warranty.
•Whentheprotectionglassisdamaged,itshouldbereplacedimmediately.
•Pleasecheckwhethertheconnectionofthepowercordissafeandreliablebeforeinstallation.
•Ifyourmainswiringdiffersinanywayfromdiagram,consultaqualiedelectrician.
•Alwaysensurethatthemainssupplyvoltageiscorrect.
•Alwaysreplacethelampwithoneofanidenticalratingandwattage.
SPECIFICATIONS
IMPORTANT SAFEGUARDS
INSTALLATION
CLEANING
•Beforecleaningalwaysensurethepowersupplyisturnedoff.
•Donotimmersetheluminaireinwater.
•Noabrasiveproducts,solvents,detergentmaybeusedtocleanthisluminaire.
•Ensurethatthettingdoesnotcomeincontactwithcorrosivechemicals,etc.
•Useasoftclothtoclean.
•Chokinghazard:Maycontainsmallparts.Keepawayfromchildren.
•Donotinsertyourngersoranypartofyourbodyintotheelectricalcontactandsocketsof
this product whilst it is connected to the electrical supply.
•Itemmayvaryslightlyfromthepictureonthecarton.