Lefroy Brooks XO 3005 is a deck mounted tap suitable for all systems, including combination boilers and low-pressure systems (with the addition of a water pump). It is recommended for use with thermostatic mixing valves to comply with local building regulations and ensure safe maximum temperatures. The tap requires a 30-32mm diameter hole for installation and can accommodate a maximum work surface thickness of 60mm. It features ceramic cartridges for smooth operation and durability, and an aerator to reduce water consumption and minimize splashing.

Lefroy Brooks XO 3005 is a deck mounted tap suitable for all systems, including combination boilers and low-pressure systems (with the addition of a water pump). It is recommended for use with thermostatic mixing valves to comply with local building regulations and ensure safe maximum temperatures. The tap requires a 30-32mm diameter hole for installation and can accommodate a maximum work surface thickness of 60mm. It features ceramic cartridges for smooth operation and durability, and an aerator to reduce water consumption and minimize splashing.

XO3000 / XO3002 / XO3005 / XO3025 / XO3100
DECK MOUNTED TAPS
INSTALLATION GUIDE
IMPORTANT INFORMATION
Professional installation
We recommend that our products are fitted by
a fully qualified professional plumber. They should
be installed correctly and in accordance with all
local water regulations and the system protected
by non-return valves (not supplied). All products
should be accessible for routine servicing.
Suits all systems
This Lefroy Brooks product is potentially suitable
for every possible application, type of boiler and
water supply pressure. However, if your supply
pressure is below 1 bar it is advisable to fit a water
pump. For systems with combination boilers,
it is not advisable to fit pumps (refer to boiler
manufacturer).
Supply connections
The hot water supply should be connected to the
left port and the cold water supply to the right
port as viewed from the front.
Supply temperature safety notice
To comply with local building regulations, current
legislation, relevant standards and codes of
practice a thermostatic mixing valve (TMV) should
be fitted (not supplied) to the hot supply. This
will restrict the temperature to a safe working
maximum temperature. Maximum allowed
temperatures vary subject to type of installation or
specification of building.
Balancing flow
If there is a significant dierence in water pressures
between hot & cold supplies, we recommend an
in-line flow suppressor/regulator (not supplied) be
fitted. This should be fitted to whichever has the
greater flow rate, in an accessible position close to
the valve.
Water quality
In hard water areas, a suitable water treatment
system should be provided to prevent limescale
deposits (calcium deposits) which may eect the
long term performance of the ceramic cartridges.
Exterior surfaces should be gently wiped with a
dry soft cloth after use to minimise water stains
and limescale deposits.
Flushing system
It is most important to flush out all pipework
thoroughly before connecting the product.
This is the single most common cause of ceramic
cartridge failure.
Servicing
All serviceable parts are available to maintain your
Lefroy Brooks product.
Ø28mm
Ø50mm
60mm maximum
109mm
129mm 122mm
Ø31.5mm
11mm
328mm
22mm Ø10mm
129mm 134mm
Ø31.5mm
22mm
Ø10mm
Ø50mm
259mm
60mm maximum
350mm
XO3000 (Without levers) & XO3002 (With levers)
XO3005
4
DIMENSIONS
Not to scale
Not to scale
Ø28mm
Ø50mm
60mm maximum
109mm
129mm 122mm
Ø31.5mm
11mm
328mm
22mm Ø10mm
129mm
60mm maximum
81mm Ø50mm
Ø28mm
79mm
Ø31.5mm
11mm
228mm
22mm Ø10mm
HOT COLD
XO3100
XO3025
5
Not to scale
Not to scale
‘O’ ring
Ø 30-32mm
Flange ring
‘C’ washer Washer
Nut
60mm
maximum
Recess
COLDHOT
6
INSTALLATION
1 Unscrew and remove the nuts, washers,
‘C’ washer and flange ring (with ‘O’ ring) from
the underside of the valve.
2 Ensure that the ‘O’ ring is located into the
recess in the underside of the flange ring. Place
the flange ring over the pre-cut Ø3032mm
hole in your work surface or pre-cast sanitary
ware. The ‘O’ ring should be in contact with
the work surface or sanitary ware.
3 Pass the flexible hoses and threaded studs
through the hole in the work surface or
pre-cast sanitary ware (maximum thickness
60mm).
4 Sit the valve into the recess in the flange ring.
Place the spout in the correct position.
5 From the underside of the work surface or
sanitary ware locate the c-washer onto the
threaded studs and secure with the washers
and nuts.
6 Ensure that the spout is in the correct
position. Using a 6mm spanner or socket
tighten the nuts suciently to secure the valve.
7 The flexible hoses can now be connected to
the appropriate supplies using compression
fittings.
8 Do not use soldered fittings as the heat may
damage the flexible hoses.
7
SERVICING – HANDLE REMOVAL & REPLACEMENT
Handle removal
1 Grasp the handle and pull firmly in a straight
line clear of the monobloc body.
Note: XO3002 models are fitted with levers.
Do not pull on the levers as this can cause
damage. Hold the body of the handle only.
Handle fitting
1 Locate the handle onto the spline a little, then
rotate the handle to check alignment. Adjust
as required.
2 Support the valve body and push the handle
firmly until it ‘clicks’ securely into position.
Pair of replacement plastic spline adapters - PXT006
8
1 Isolate the hot and cold water supplies and
drain the system as required.
2 Remove the appropriate handle(s) as in the
previous section.
3 Using a 17mm a/f spanner or socket unscrew
the cartridge and remove.
4 Check inside the valve body for any debris or
limescale. Wipe clean as required.
5 Screw a new ceramic cartridge into the valve
body and tighten using a 17mm spanner or
socket.
6 Open the hot and cold supplies.
7 Check for leaks.
8 Replace the handle(s) as in previous section.
9 Check operation of the cartridge(s).
SERVICING – TO REPLACE CERAMIC CARTRIDGES
Pair of replacement ceramic cartridges - PXT005
XO3000
XO3002
XO3005
XO3100
PXT011
PXT013
Washer
Aerator
Cover
Washer
Aerator
Cover
End cap
End cap
9
SERVICING – CLEANING OR REPLACING THE AERATOR
1 Using a 1.5mm hexagonal key, unscrew and
remove the set screw from the underside of
the end cap.
2 Pull o the nozzle to reveal the aerator.
3 Using a 22mm a/f spanner, unscrew and
remove the aerator cover and aerator from
the spout.
4 The aerator can be cleaned in warm soapy
water or replaced.
5 Check the spout for debris and limescale.
Wipe clean as required.
6 Fit the aerator and assemble in the reverse
order.
Flow straightener
assembly
Threaded body
Cover
Flow straightener
PXT028
1mm thick washer
Threaded body
2mm thick washer
10
SERVICING – FLOW STRAIGHTENER CLEANING OR REPLACEMENT
FOR XO3025 MODEL ONLY
1 Unscrew and remove the flow straightener
assembly.
2 Unscrew and remove the threaded body from
the valve body using suitable hexagonal key.
3 Check the spout for debris and limescale.
Wipe clean as required.
4 The flow straightener can be cleaned in warm
soapy water or replaced.
5 Fit the flow straightener in reverse order.
Whilst every effort is made to ensure the accuracy of these, they are subject to change without
notice as part of the company’s product development process. The use of trademarks, product design
and artwork is subject to licence or agreement with LBIP Ltd. The design registrations, trademark registrations
and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited.
The right to modify designs and dimensions is reserved. LBIP Ltd is a member of ACID (Anti Copying in Design). E&OE
© LBIP Ltd 2022
CONTRACT ENQUIRIES
+44 (0)1992 708 316
info@lefroybrooks.co.uk
CUSTOMER SERVICE, SPARES & TECHNICAL ENQUIRIES
+44 (0)1902 390 894
technical@lefroybrooks.co.uk
LEFROYBROOKS.CO.UK
20.065.169C / AUGUST 2022
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Lefroy Brooks XO 3005 Installation & Servicing Guide

Type
Installation & Servicing Guide
This manual is also suitable for

Lefroy Brooks XO 3005 is a deck mounted tap suitable for all systems, including combination boilers and low-pressure systems (with the addition of a water pump). It is recommended for use with thermostatic mixing valves to comply with local building regulations and ensure safe maximum temperatures. The tap requires a 30-32mm diameter hole for installation and can accommodate a maximum work surface thickness of 60mm. It features ceramic cartridges for smooth operation and durability, and an aerator to reduce water consumption and minimize splashing.