Leonton PG2-0800-M12XB-24-67 User manual

Category
Network switches
Type
User manual

Leonton PG2-0800-M12XB-24-67 is a industrial gigabit unmanaged Ethernet switch with 8*10/100/1000Tx with IEEE 802.3at compliant ports (30W/port). Possible use cases:

  • High bandwidth and long-distance communication: Suitable for industrial automation applications and harsh environments that require high bandwidth and long-distance communication.
  • Redundant power with dual power input design: Supports power redundancy with a dual power input design with reverse polarity protection, ensuring uninterrupted operation even in the event of a power failure.
  • Relay warning function: Alerts users about occurring fault status, providing timely notification for proactive maintenance.

Leonton PG2-0800-M12XB-24-67 is a industrial gigabit unmanaged Ethernet switch with 8*10/100/1000Tx with IEEE 802.3at compliant ports (30W/port). Possible use cases:

  • High bandwidth and long-distance communication: Suitable for industrial automation applications and harsh environments that require high bandwidth and long-distance communication.
  • Redundant power with dual power input design: Supports power redundancy with a dual power input design with reverse polarity protection, ensuring uninterrupted operation even in the event of a power failure.
  • Relay warning function: Alerts users about occurring fault status, providing timely notification for proactive maintenance.
Leonton
PG20800M12XB2467
UserManual
Version1.0
©Copyright2018LeontonTechnologiesCo.,Ltd.
AllRightsReserved
Thisdocumentcontainsinformation,whichisprotectedbycopyright.Reproduction,adaptationor
translationwithoutpriorpermissionisprohibited,exceptasallowedunderthecopyrightlaws.
Disclaimer
LeontonTechnologiesCo.,Ltd.providesthismanualwithoutwarrantyofanykind,expressedor
implied,includingbutnotlimitedtotheimpliedwarrantiesofmerchantabilityandfitnessfora
particularpurpose.LeontonTechnologiesCo.,Ltd.maymakeimprovementsand/orchangestothe
productand/orspecificationsoftheproductdescribedinthismanual,withoutpriornotice.
LeontonTechnologiesCo.,Ltd.willnotbeliableforanytechnicalinaccuraciesortypographical
errorsfoundinthisguide.Changesareperiodicallymadetotheinformationcontainedhereinand
willbeincorporatedintolaterversionsofthemanual.Theinformationcontainedissubjectto
changewithoutpriornotice.
FCCNotice
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,
pursuanttoPart15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotection
againstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcan
radiateradiofrequencyenergy.Itmaycauseharmfulinterferencetoradiocommunicationsifthe
equipmentisnotinstalledandusedinaccordancewiththeinstructions.However,thereisno
guaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningthe
equipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreof
thefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentandreceiver.
Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver
isconnected.
Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
DéclarationFCC
CetéquipementaététestéetreconnuconformeauxlimitesdelaclasseApourleséquipements
numériques,conformémentàlasection15desRéglementationsFCC.Ceslimitessontconçues
pourfourniruneprotectionraisonnablecontretoutesinterférencesnuisiblesdansunmilieu
résidentiel.Cetéquipementgénère,utilise,etpeutémettredel’énergiedefréquenceradioet,s’il
n’estpasinstalléetutiliséconformémentaumanueld’instruction,peutperturberlaréception
radio.Cependant,iln’estpasgarantiquel’équipementneproduiraaucuneinterférencedansune
installationparticulière.Sicetéquipementcausedesinterférencesnuisiblesàlaréceptionradioou
télévisée,quipeuventêtredéterminéesenl’éteignantetlerallumant,l’utilisateurestencouraà
essayerderemédierauproblèmeenprenantlesmesuressuivantes:
Réorienteroudéplacerl’antenneréceptrice.
Augmenterladistanceentrel’équipementetlerécepteur.
Connecterl’équipementàuneprisesecteursuruncircuitdifférentdeceluiutiliséparle
récepteur.
Consulterlenégociantouuntechnicienradio/TVexpérimenté.
Caution:Anychangesormodificationsnotexpresslyapprovedbythegranteeofthisdevicecould
voidtheuser'sauthoritytooperatetheequipment.
ATTETNION:Toutchangementoumodificationnonexpressémentapprouvéparleconcessionnaire
decetappareilpourraitannulerl'autoritédel'utilisateuràutiliserl'équipement.
CEMarkWarning
ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferencein
whichcasetheusermayberequiredtotakeadequatemeasures.
CEMarkAVERTISSEMENT
CeciestunproduitdeclasseA.Dansunenvironnementdomestique,ceproduitpeutêtreutiliséen
présenced'interférencesradio.
Thisdocumentisthecurrentofficialreleasemanual.Pleasecheckourwebsite(www.leonton.com)
foranyupdatedmanualorcontactusbyemail(sales@leonton.com).
Contents
Overview.......................................................................................................................1
KeyFeatures...............................................................................................................1
PackageContents.......................................................................................................2
SafetyPrecaution.......................................................................................................2
HardwareDescription...................................................................................................3
PhysicalDimensions...................................................................................................3
FrontPanel.................................................................................................................4
BottomView..............................................................................................................5
LEDIndicators.............................................................................................................6
EthernetPorts............................................................................................................7
PowerInputs..............................................................................................................8
RelayContactandDigitalInput..................................................................................9
Grounding................................................................................................................11
PrioritizationofPoEports........................................................................................11
BypassFunction........................................................................................................12
PrioritizationofPackets...........................................................................................12
MountingInstallation..................................................................................................13
WallMounting..........................................................................................................13
HardwareInstallation..................................................................................................15
InstallationSteps......................................................................................................15
MaintenanceandService............................................................................................17
TroubleShooting.........................................................................................................18
1
Overview
ThismodelisratedIP67andinstallationbyWallMounting.Eachunitofthisindustrialgigabit
unmanagedEthernetswitchhas8*10/100/1000TxwithIEEE802.3atcompliantports(30W/port),
suitableforapplicationsthatrequirehighbandwidthandlongdistancecommunication.
Inordertopreventunregulatedvoltage,thismodelprovideshighEFTandESDprotection.This
alsoallowsittofunctioninharshenvironments,aswellassupportpowerredundancywithadual
powerinputdesignwithreversepolarityprotection.Therelaywarningfunctionalertsusersabout
occurringfaultstatus.
Thismodelhavinganoperatingtemperatureof‐10°C~60°Cisdesignedtomeetanyneedsfor
industrialautomationapplicationandharshenvironments.
KeyFeatures
Interface&Performance
AllcopperEthernetportssupportautoMDI/MDIXfunction
Embedded8*10/100/1000TxwithIEEE802.3atcompliantports(30W/port)
Storeandforwardswitchingarchitecture
8KMACAddressTable
Supports12.2KbytesJumboFrame
4Mbitsmemorybuffer
PowerInput
RedundantpowerDC2455VthroughM124PinTCodedmaleconnector
Max.current8.8A
Max.PoEoutput:200Watts
RelayContact:24VDC,1Aresistive,throughM125PinACodedfemaleconnector
Certification
CE/FCC
OperatingTemperature
Standardoperatingtemperaturemodel:‐10°C~60°C

2
Case/Installation
Aluminumcase
IP67protection
InstallationinaPollutionDegree2industrialenvironment
Wallmountdesign
PackageContents
1xPG20800M12XB2467
1xQuickInstallationGuide
10xM12ProtectiveCaps
SafetyPrecaution
Attention
IftheDCvoltageissuppliedbyanexternalcircuit,pleaseuseaprotectiondeviceonthepower
supplyinput.SupplybyULListedindustrialusepower.TheindustrialEthernetswitch’shardware
specs,ports,cablinginformation,andwiringinstallationwillbedescribedwithinthisusermanual.
ATTETNION
SilatensionCCestfournieparuncircuitexterne,veuillezutiliserundispositifdeprotectionsur
l'entréed'alimentation.FournitureparcourantindustrielhomologuéUL.Lesspécifications
matériellesducommutateurEthernetindustriel,lesports,lesinformationsdecâblageet
l’installationducâblageserontdécritsdanscemanueldel’utilisateur.
3
HardwareDescription
PhysicalDimensions
Figure2,below,showsthephysicaldimensionsofPG20800M12XB2467.
(WxHxD)is253.6mmx122mmx116.1mm
Figure2:PG20800M12XB2467PhysicalDimensions
4
FrontPanel
ThefrontpanelofthePG20800M12XB2467industrialPoE+gigabitunmanagedEthernet
switchisshownbelowinFigure3.
Figure3:TheFrontPanelofPG20800M12XB2467
1. Power1LED
2. Power2LED
3. FaultLED
4. PoELoadLED
5. 10/100/1000MbpsLink/ActLED
6. PoEOutputLED
7. ScrewHolesforWallMounting
8. GroundingScrew
9. PowerInputPort:M124PinTCodedMaleConnector
10. ProductLabel
11. 10/100/1000BaseT(X)EthernetPort:FromportG1toG8withM128PinXCodedFemale
Connector
5
BottomView
Figure4,below,showsthebottompanelofthePG20800M12XB2467thatisequippedwith8x
M12XCodedfemaleconnectors,1xM12TCodedmaleconnectorfordualDCpowerinputs(24
55VDC),and1xM12ACodedfemaleconnectorforrelaycontact/digitalinput..
Figure4:BottomPanelViewofPG20800M12XB2467
6
LEDIndicators
ThereareLEDlightindicatorslocatedonthefrontpaneloftheindustrialEthernetswitchthat
displaythepowerstatusandnetworkstatus.EachLEDindicatorhasadifferentcolorandhasits
ownspecificmeaning,seebelowinTable1.
LED Color Description
P1 Green On Powerinput1isactive
Of
f
Powerinput1isinactive
P2 Green On Powerinput2isactive
Of
f
Powerinput2isinactive
FAULT Red
On
Therewere threepossibleconditions wouldmakeLEDlightup:
1.IfthecurrentPoEoutputofallconnectedPDswasoverload
(>200Watts)
2.IfPower1orPower2wasinactive
3.IfthecurrentPoEoutputofoneormorePDswereoverload
(>30Watts)
Off
SincethelastresetoftheFAULTLED,thePoEoutputofall
connectedPDshasnotover200WandnoPDhasbeenoverloaded
inthisperiodandthepower1&power2havenotfailed
PoE LOAD
Of
f
Of
f
ThecurrentPoEoutputofallconnectedPDsis≤50%
GreenOnThecurrentPoEoutputofallconnectedPDsis51% ~ 70%
BlueOnThecurrentPoE outputofallconnectedPDsis71%~ 90%
RedOnThecurrentPoEoutputofallconnectedPDsis91%~ 100%
Note:TheMax.PoEoutputofthisswitchis200Watts.
L/A
(PortG1toG8)
Green
On Connectedtonetwork with 1000 Mbps
Flashing Networkingisactive
Of
f
Notconnectedtonetwork
Amber
On Connectedtonetwork with 10/100 Mbps
Flashing Networkingisactive
Of
f
Notconnectedtonetwork
PoE.
(PortG1toG8) Orange
On ThecurrentPoEoutputisenabled
FlashingOverloadoccurred(>30Watts)attheconnectedPD
Off ThecurrentPoEoutputisdisabled
Table1:LEDIndictorsforPG20800M12XB2467
NOTE:"P1/P2"istheabbreviationfor"Power1/Power2",and"L/A"isfor"Link/Activity".
7
EthernetPorts
M12Interface (AutoMDI/MDIX)
ConnectionFormat:M128PinXCodedFemaleConnector
Transmissionrate:10/100/1000Mbit/s
PreparetheM128PinXCodedEthernetPortmatingcableforEthernetconnection.TheM12
XCodedEthernetportsareautosensingfor10BaseT,100BaseTX,or1000BaseTdevices
connections.AutoMDI/MDIXmeansthatyoucanconnecttoanotherswitchorworkstation
withoutchangingstraightthroughorcrossovercabling.SeepinassignmentshowninTable2.
M128PinXCodedFemaleConnector
Pinouts10/100BaseT(X)Signal 1000BaseTSignal
1TransmitData+(TX+)BI_DA+
2TransmitData‐(TX)BI_DA‐
3ReceiveData+(RX+)BI_DB+
4ReceiveData‐(RX)BI_DB‐
5 BI_DD+
6  BI_DD‐
7 BI_DC‐
8  BI_DC+
Table2:PinassignmentofM12Ethernetconnector
Note:“+”andsignsrepresentthepolarityofthewiresthatmakeupeachwirepair.
ConnectionofCables
Usethetwistedpaircable,category5eortheabovecablingforM12portconnections.Thecable
betweentheEthernetswitchandthelinkpartner(switch,hub,workstation,etc.)mustbeless
than100meters(328ft.)long.
MinimumWireGauge:24AWG
MaximumTransmissionLength:100m(328ft)
Caution(
ATTETNION
):
1.Pleaseusewithcopperconductorsonly.
(DESTINÉÀÊTREUTILISÉAVECDESCONDUCTEURSENCUIVRESEULEMENT.)
2.Useconductorswithinsulationratedforatleast60°C.
(AVERTISSEMENT:EMPLOYERDESCONDUCTEURSPOURAUMOINS60°C.)
3.BasetheconductorAmpacityonamaximumterminationtemperatureof60°C.
(LECOURANTADMISSIBLEDUCONDUCTEURDOITÊTREDÉTERMINÉENFONCTIOND’UNETEMPÉRATURE
MAXIMALEAUXTERMINAISONSDE60°C.)
8
PowerInputs
ThisindustrialEthernetswitchprovidesdualDCpowerinputsforredundancythroughaM124
PinTCodedmaleconnector.PreparetheM124PinTCodedcableforpowerconnection.Table3
showsthepinassignment.
M124PinTCodedMaleConnector
PinoutsFunction
1V1+
2V1‐
3V2‐
4V2+
Table3:Pinassignmentofthepowerconnecter
ConnectionofCables
MinimumWireGauge:18AWG
Pleasefollowthebelowstepstoinsertthepowerwire.
Step 1.
Insertthepositiveandnegativepowerwiresintothepowerconnectorontheindustrial
EthernetswitchwithPower1(V1+,V1),andPower2(V2+,V2).
Step 2.
Tightenthescrewnuttopreventtheconnectorfromloosening.
Caution:ThepowerinputspecificationiscompliedwiththerequirementsofSELV
(SafetyExtraLowVoltage),andthepowersupplyshouldbecompliedwithUL610101&
UL610102201.
Attention:Laspécificationdelapuissanceabsorbéeestconformeauxexigencesdela
normeSELV(SafetyExtraLowVoltage),etl'alimentationélectriquedoitêtreconforme
auxnormesUL610101etUL610102201.
9
RelayContactandDigitalInput
TheEthernetswitchisequippedaM125PinACodedfemaleconnectorwithanormallyclosed
relaycontactforfaultalarmandadigitalinput(DI)forresettingrelayandrebootingunit.Thepin
assignmentofthisconnectorisshowninTable4.
M125PinACodedFemaleConnector
PinoutsFunctionDescription
1DI+DigitalInput+
2RelayComCommon
3Relay(N.C.)NormallyClosed
4DI‐ DigitalInput‐
5NANotAssigned
Table4:Pinassignmentoftherelaycontactanddigitalinput
ConnectionofCables
MinimumWireGauge:24AWG
RelayContact
ByusingaM125PinACodedcabletoconnectthenormallyclosedrelaycontact,itwilldetectthe
faultstatusandformanopencircuitwhenanyofthefollowingabnormalconditionsoccurs:
1.IfthecurrentPoEoutputofallconnectedPDswasoverload(>200Watts)
2.IfthecurrentPoEoutputofoneormorePDswereoverload(>30Watts)
3.IfPowerinput1orPower2wasinactive
AconnectionofrelaycontactforfaultalarmisshownbelowinFigure5.
Figure5:Wiringtherelaycontactforfaultalarm
10
WhentheEthernetswitchisoperatingnormally,therelaycontactisaclosedcircuit.Whenthe
switchhasanyfaultstatus(PoEoverloadorpowerfailure),therelaycontactcircuitisopenedand
theFAULTLEDlightsup.Inaddition,evenafterevenaftertheabnormalsituationhasbeen
removed,therelaycontactisstillopenandFAULTLEDremainsactive,unlessusingthedigital
inputtoresetthat.SeethenextsectionforinformationonDigitalInput.
Note:Ifonlyusingonepowersource,jumperPin1toPin4andPin2toPin3ontheM124PinT
Codedpowercabletoeliminatepowerfaultalarm.
DigitalInput(DI)
Thedigitalinputisusedformonitoringtwoexternaleventsviaanexternalvoltagesource.When
thevoltagelevelondigitalinputpinschangesfromhighvoltagetolowvoltage,theDIfunction
willbetriggered.Table5isshownadetailspecificationofthedigitalinput.
SpecificationDescription
Level0(Low)30~8VDCWilltriggerDIfunction(activetriggerstates)
Level1(High)10~30VDCNormalStatus(inactivetriggerstates)
Nominalinputvoltage24VDC 
Max.inputvoltage30VDC
Nominalinputcurrent5mA(typical)
Max.inputcurrent8mA
Table5:SpecificationofDI
AsdescribedinRelayContactsection,ifthefaultstatus(totaloutputpoweroverdevice'sPoE
powerbudget,oranyoneofPoEportsover30Watts)happens,youhavetouseDIfunctionto
resettheFaultLED,sotherearetwoDIfunctionsthisunitsupportsformanuallyresetorreboot
thedevice,whichisshownasfollows.
1.Whenthetriggertime<4seconds,therelaycontactwillberesetandtheFaultLEDlight
down.
2.Whenthetriggertime>4seconds,theEthernetswitchwillberebooted.
11
Grounding
Groundingandwireroutinghelplimittheeffectsofnoiseduetoelectromagneticinterference
(EMI).Runthegroundconnectionfromthegroundscrewtothegroundingsurfacepriorto
connectingdevices.ThegroundingscrewsymbolisshownblowinFigure6.
Figure6:Groundingscrew
Caution:Usingashieldedcableachievesbetterelectromagneticcompatibility.
ATTETNION:L'utilisationd'uncâbleblindépermetd'obtenirunemeilleurecompatibilité
électromagnétique
PrioritizationofPoEports
TheprioritizationofPoEisthepriorityclassofpower.Therehasadecreasingruleinprioritization
fromportG1toG8,whichmeanstheEthernetswitchassignsalowernumberedporttoahigher
priority.Therefore,portG1usesthehighestpriorityandportG8usesthelowesttodetermine
whichportswillprovidetheconnectedpowereddevice(PD)power.
OnalleightEthernetportofthisswitch,eachportcanprovideupto30Wandthemaximumtotal
PoEoutputis200Watts.IftheswitchcanprovidepowerforallconnectedPD,itdoesn'tusethe
prioritizationruletoallocatepower.OnlyifthecurrentPoEprovisioningonallconnectedPD
oversubscribestheavailablepower(above200W),oneormorelowerpriorityportswillbe
removedpowerfrominorderofpriorityuntiltheswitchcanmeetthetotalpowerconsumptionfor
other,higherpriorityports.
12
BypassFunction
ThisEthernetswitchsupportsbypassfunctionbytwoEthernetports(G7andG8).Whenoneofthe
Ethernetswitcheslosespower,Ethernetports(G7andG8)willbypassthepowerlostEthernet
switchtopreventthenetworkfromdisconnecting.
TakeFigure7forexample,ifSwitchBhaspowerfailure,thebypassfunctionwillbeactivated
automatically,anditwillbypassSwitchBandbridgeG7toG8ofSwitchB,sothatthedata
transmissionpath(fromSwitchAtoC)canremainconnectedandunaffected.
Figure7:Exampleofbypassfunction
PrioritizationofPackets
ThisEthernetswitchprovidesQoSbasedIEEE802.1pclassofservice(CoS)valuestosupports0to7
CoSvalues,whichmappedto4priorityqueues,sothatTrafficisforwardedsequentiallyaccording
tothepriority,thehighestprioritypackettransmitfirstbytheswitch.QualityofService(QoS)is
usedtoensurethepriorityofnetworktrafficreceivingcorrecttreatments,soiteliminatesthe
unpredictabilityissueofnetworktraffic.
Apriorityqueueisadatatypewhichidentifiesanitemwiththehighestpriorityinasystem.To
mapeachCoSvaluetoaQoSpriorityqueueistoprioritizethetypeoftrafficatcongestionpoints
ofthenetwork.TheTable6belowisthepriorityqueuemapping.
CoSValue01234567
QoSPriorityQueueLowLowNormal Normal Medium MediumHighHigh
Table6:Priorityqueuemapping

13
MountingInstallation
WallMounting
FollowthestepsbelowtomounttheindustrialEthernetswitchtoawallusingthescrewholesas
shownbelowinFigure8.
Step1. Prepare4screwsformountingtheswitchtoawall.
Note:RecommendedusetheM6screws.
Step2. BasedontheFigure9:PhysicalDimensionswhichisshownthepositionsof4screwholes
ontheleftandrightsideoftheswitchtomake4screwholesonawallaccordingly.
Step3. Insertthescrewsthroughthescrewholesontheswitchandscrewtheswitchintothe
wall.ShownbelowinFigure8.
Step4. Toremovetheswitchfromthewall,dotheoppositefromthestepsabove.
Note:Makesuredisconnectallcablesfromtheswitchbeforeremovingtheunitfromthe
wall.
14
Figure9:Positionofthescrewholes
Caution:
“Wall”meansindustrialcontrolpanelwall.
ATTETNION:"Mur"signifieunmurdepanneaudecommandeindustriel.
15
HardwareInstallation
InstallationSteps
ThissectionwillexplainhowtoinstallPG20800M12XB2467.
Caution:
1. Thisdeviceisintendedforuseindoorandataltitudesupto2000meters.Inaddition,the
environmentalconditionshouldbemaximumrelativehumidity80%fortemperaturesupto
31°Cdecreasinglinearlyto50%relativehumidityat40°C.
2. Thedeviceisintendedtobeinstalledinanindustrialcontrolenclosureandpanel.
3. Foruseinacontrolledenvironment.Refertomanualforenvironmentalconditions.
ATTENTION:POURUTILISATIONENATMOSPHÈRECONTRÔLÉE.CONSULTERLANOTICETECHNIQUE.
ATTETNION
1. Cetappareilestconçupourêtreutiliséàl’intérieuretàdesaltitudesallantjusqu’à2000
mètres.Deplus,lesconditionsambiantesdoiventêtreunehumiditérelativemaximalede
80%pourdestempératuresallantjusqu'à31°C,diminuantlinéairementjusqu'àune
humiditérelativede50%à40°C.
2. L'appareilestdestinéàêtreinstallédansunboîtieretunpanneaudecommandeindustriels.
3. Pouruneutilisationdansunenvironnementcontrôlé.Reportezvousaumanuelpourles
conditionsenvironnementales.
InstallationSteps
Step 1.
UnpacktheindustrialEthernetswitchfromtheoriginalpackingbox.
Step 2.
TohangtheindustrialEthernetswitchonawall,pleaserefertotheMountingInstallation
section.
Step 3.
PowerontheindustrialEthernetswitchandthenthepowerLEDlightwillturnon.
Ifyouneedhelponhowtowirepower,pleaserefertothePowerInputssection.
PleaserefertotheLEDIndicatorssectionforLEDlightindication.
Step 4.
PreparetheM12cableforEthernetconnection.
Step 5.
InsertonesideoftheM12cableintoswitch’sEthernetportandontheothersideinto
thenetworkingdevice’sEthernetport.TheEthernetport’s(L/A)LEDontheindustrial
Ethernetswitchwillturnonwhenthecableisconnectedtothenetworkingdevice.
PleaserefertotheLEDIndicatorssectionforLEDlightindication.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Leonton PG2-0800-M12XB-24-67 User manual

Category
Network switches
Type
User manual

Leonton PG2-0800-M12XB-24-67 is a industrial gigabit unmanaged Ethernet switch with 8*10/100/1000Tx with IEEE 802.3at compliant ports (30W/port). Possible use cases:

  • High bandwidth and long-distance communication: Suitable for industrial automation applications and harsh environments that require high bandwidth and long-distance communication.
  • Redundant power with dual power input design: Supports power redundancy with a dual power input design with reverse polarity protection, ensuring uninterrupted operation even in the event of a power failure.
  • Relay warning function: Alerts users about occurring fault status, providing timely notification for proactive maintenance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages