USER MANUAL
Read This Manual
Inside you will find many helpful hints on how
to use and maintain your dehumidifier properly.
Just a little preventative care on your part can
save you a great deal of time and money over
the life of your dehumidifier. You’ll find many
answers to common problems in our
“troubleshooting” section. Review the chart of
Troubleshooting Tips before calling your
service engineers.
keeping your home
safe and clean
ECOAIR TECHNICAL SUPPORT
UK TEL: 0845 388 0007
1
IMPORTANT INSTRUCTIONS
The following advice and instructions are important from the start:
This will help you optimize the operation of your unit.
contains refrigerant.
Failure to comply with
these instructions may
Do not install and use your dehumidifier before reading these instructions in full.
1.Your unit must always be used in an upright position, as it
2.After unpacking your unit, place it upright to allow the
refrigerant
agent to stabilize, and wait 4 hours before use.
damage the unit and will
of electrical and electronic appliances.
3.This product must not be disposed of with the domestic waste.
This product must be disposed of at an authorized place for recycling
4.The appliance should not be installed in the bathroom.
5.The appliance should be installed in accordance with national wiring
regulations and must be positioned so that the plug is accessible.
invalidate the warranty.
7.Before the first operation: check if the float in the tank is at the correct
position. If the position is not correct, correct this by hand.
6.If the power cord is damaged, it must be replaced by the manufacturer,
service agent or a electrician.
CONTENTS
IMPORTANT INSTRUCTIONS ........................................................
IMPORTANT SAFETY INFORMATION ...........................................
THE CONTROLS ON THE DEHUMIDIFIER ....................................
USING THE DEHUMIDIFIER ..........................................................
CARE AND CLEANING OF THE DEHUMIDIFIER ..........................
TROUBLESHOOTING ....................................................................
LONG TERM STORAGE ................................................................
SPECIFICATIONS ..........................................................................
How the dehumidifier Operates ...............................................
Automatic defrost .....................................................................
Choosing a location ..................................................................
SAFETY PRECAUTIONS ........................................................
Removing collected Water ........................................................
Water level ...............................................................................
Grille and Case .........................................................................
Water tank ................................................................................
Air filter .....................................................................................
WEE/EC2601UR
BS PLUG WIRING ............................................................................
1
2
3
3
4
5
5
5
5
6
6
7
7
7
7
8
9
9
4
ABOUT THE CONTROLS ON THE DEHUMIDIFIER
NOTE: When the tank is full or removed, the
controls cannot be set.
ON/OFF
Press to turn the dehumidifier on and off.
FILTER
Filter indicator reminds you to check and
clean your filter.Remove the filter and clean it.
Press to turn off the Clean the Filter light. See
the Care and Cleaning section.
Humidity Set Control
The humidity level can be set within a range
of 80% to 35% RH (Relative Humidity) at
intervals of 5%.
In the LAUNDRY mode (CO)
For Laundry or continuous running, select the
LAUNDRY mode (CO), the dehumidifier will
dehumidification settings if attached to a hose
to drain or until the tank is full.
To set a lower desired humidity setting, press
press the - button and set to a lower percentage
To set a higher desired humidity setting, press
the + button and set to a higher percentage
value (%).
Display
This is an active humidistat and can adjusted to
your required levels (by using +/- button).
FAN SPEED
Controls the fan speed.
Press to select High or Low fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Low.
Select a choice of 2 hour or 4 hour timer.
TIMER
TANK FULL Light
Glows when the tank is ready to be emptied,
or when the tank is removed or not replaced
in the proper position.
Alarm
If the tank is full or missing for more than three
minutes, an alarm will sound for about 10 seconds
to remind you to empty and replace the tank.
Auto Shut Off
The Water Level Control Switch shuts off the
dehumidifier when the tank is full, or when
the tank is removed or not replaced in the
correct position.
Auto Defrost
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
Auto Restart
In the case of a power outage or interruption,
the unit will automatically restart, in the settings
last used, after the power is restored.
Other Features
operate continuously at its maximum
value (%).
the humidity control to 45% or 50%.
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.
After the unit has stopped (Other than tank full),it
will not restart for approx. 3 minutes. This is to
protect the unit and is not a fault. Operation will
Wait 3 minutes before resuming operation
automatically restart after 3 minutes.
When you first use the dehumidifier
TIP
4H
2H
2
1
5
6
High and Low fan
indicator lights
Tank full light indicates
tank needs to be emptied
or it is not in the proper place
Laundry or Continuous
indicator light
Power On
indicator light Clean the Filter
indicator light
4
3
4 hour or 2 hour
indicator lights
delay on/off
5
USING THE DEHUMIDIFIER
When first using the dehumidifier, operate the unit continuously 24 hours.
How the Dehumidifier Operates Automatic Defrost
Moist, humid air is drawn over a cold refrigerated
dehumidifying coil. Moisture in the air condenses
on this coil and drains into a tank (or through
a hose and drain).
Dry, clean air is drawn through the condenser
where it is heated and discharged out the top grille
into the room.
It is normal that the surrounding air to become slightly
warmer as the dehumidifier operates.
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
In defrosting mode, the fan motor will run,
normally the compressor will stop running.
Choosing a Location
A dehumidifier operating in a basement will have
little or no effect in drying an adjacent enclosed
storage area, such as a closet, unless there is
adequate circulation of air in and out of the area.
Do not use outdoors.
This dehumidifier is intended for indoor residential
applications only. This dehumidifier should not be
used for commercial or industrial applications.
Place the dehumidifier on a smooth, level floor
strong enough to support the unit with a full tank
of water.
Allow at least 12 inches of air space around unit
for good air circulation except the air outlet must
be at least 40 inches from any obstruction.
Place the dehumidifier in an area where the
temperature will not below 5°C. Or the coils
can become covered with frost, which may
reduce performance.
Use the dehumidifier to prevent moisture damage
of furnitures books or valuables.
Use the dehumidifier in a basement to help prevent
moisture damage.
Close all doors, windows and other outside openings
of the room. When in operation to maximise
effectiveness
NOTE:The dehumidifier has rollers to aid placement,
but it should only be rolled on smooth, flat surfaces.
YES NO
USING THE DEHUMIDIFIER
Always make sure the water tank is locked into place o n the dehumidifier.
Removing Collected Water
There are 2 ways to remove collected water:
Use the tank. When the tank is removed,
the unit will shut off. Empty and replace the
tank.
1
2Use a hose. Water can be automatically
emptied into a floor drain by attaching a
NOTE: Support tank with
both hands when emptying.
NOTES:
The tank must be in place and securely
seated for the dehumidifier to operate.
Water Level
The dehumidifier will turn off automatically
when the tank is full, or when the tank is
removed or not replaced in the proper position.
The tank must be replaced in the correct position for
the unit to work. A light will show if the tank is not
replaced correctly.
6
Important: Do not use the hose if using the
water tank to collect water. When the hose
is connected, water will be drained out through
it onto floor instead of into the tank.
Do not remove the tank while the unit
is in operation or it has just stopped.
Otherwise it may cause some water to
drip from the draining pan.
14mm inner diameter hose.
1) Remove the continuous drain cap 1by turning
it anti clockwise then remove the rubber
stopper 2 from the spout.
2) Turn the drain connector clockwise to the spout.
3) Insert the drainage hose into the drain connector.
×× ×
ATTENTION: When using continuous drainage option,
place dehumidifier on a level surface and make sure
the hose is clear of any obstructions and is directed
downwards. Press down the drain cap so it rests on top of
the hose.
Avoid placing dehumidifier on an uneven surface and
improper hose installation as it may result in the unit
shutting off. Empty water tank if shut off occurs,
then check dehumidifier location and hose for proper
setup.
2
1
7
CARE AND CLEANING OF THE DEHUMIDIFIER
Turn the dehumidifier off and remove the plug from the wall outlet before cleaning.
Grille and Case
To clean the case:
Wipe with damp cloth (Use a mild detergent if neccessary).
Do not use bleach or abrasives.
To clean the front grille:
Use a vacuum attachment or brush.
Water Tank
To clean:
Every few weeks, clean the tank to prevent
growth of mold, mildew and bacteria. Partially fill
the tank with clean water and add a little mild
detergent. Swish it around in the tank, empty
and rinse.
NOTE: Do not use a dishwasher to clean the
water tank.
To remove:
Remove the tank and pour any water out.
To replace:
Slide the tank into the dehumidifier.
NOTE: The tank must be in place and securely seated
for the dehumidifier to operate.
Air Filter
The air filter should be checked and cleaned at
least every 2 weeks of operation or when the FILTER
light turns on.
Caution: Do not operate the dehumidifier
without a filter because dirt will gather and cause
malfunction.
NOTE: Do not use a dishwasher to clean the filter.
Clean the Filter indicator light will glow to remind
you to clean the filter. Remove the filter and clean it.
Replace the filter and press the Filter RESET pad to
turn off the Clean the Filter light.
To remove:
Press the two buttons, then pull out the filter.
To clean:
Vacuum off dust and debris from the filter. Clean the filter
with warm, soapy water. Rinse and let the filter dry
before replacing it.
To install:
Put the filter back into the dehumidifier.
NOTE: DO NOT rinse or put the filter in a dishwasher.
Buttons
8
Make sure the dehumidifiers plug is pushed completely
into the outlet.
Dehumidifier has reached its The dehumidifier automatically turns off when either
preset level or tank is full. condition occurs. Change to a lower setting or empty
the tank and replace properly.
Tank is not in the The tank must be in place and securely seated for the
proper position. dehumidifier to operate.
Power failure. There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normal dehumidifying
for 3 minutes after it is turned back on.
Did not allow enough time When first installed, allow at least 24 hours to maintain
to remove the moisture. the desired dryness.
Airflow is restricted. Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidifier. See the
Choosing a Location section.
Dirty filter. See the Care and Cleaning section
The Humidity Control may
not be set low enough.
Doors and windows may not Check all doors, windows and other openings
be closed tightly. are securely closed.
Clothes dryer may be Install the dehumidifier away from the dryer.
blowing moisture-laden The dryer should be vented to the outside.
air into the room.
Room temperature Moisture removal is best at higher room
temperatures.
is too low. Lower room temperatures will reduce the moisture
removal rate. Models are designed to be operated at
temperatures above 5°C.
Area to be dehumidified The capacity of your dehumidifier may not be adequate.
is too large.
Dehumidifier runs
too much
Doors and windows are open. Close all doors and windows to the outside.
Dehumidifier has been recently This is normal. Frost will usually disappear
turned on, or room temperature within 60 minutes. See the Automatic Defrost section.
is below 5°C.
The compressor will turn off This is normal. Wait approximately 3 minutes and set the
and the fan will automatically fan as desired.
continue to run for
approximately 3 minutes at a
fixed setting.
There is sound created when
wind passing the unit. That is
the sound of wind.
This is normal.
Hose connection may be loose. Check the hose connection.See the Removing Collected
Water section.
Intend to use the tank to Disconnect the hose if using the tank to collect water.
collect water, but a hose See the Removing Collected Water section.
is attached.
TROUBLESHOOTING
Problem Possible Causes What To Do
Dehumidifier
does not start
The dehumidifier
is unplugged.
Dehumidifier does
not dry the air as it
should
For drier air
, press the “-” pad and set to a lower percent
value (%) or at LAUNDRY for maximum
dehumidification.
Frost appears on
the coils
Controls cannot be
set
Fan noise
Water on floor
The unit may have been
placed on an unever surface
Move the dehumidifier onto another surface such as
a table top to test. Use a spirit level to test levelness.
Make sure there is no water left in the water tank and take off the draining hose.
Clean the unit and pack it well ideally in its original packaging to keep it from dust.
9
220-240V~
50Hz
đ5đ-35
220W
10.5kg
Take off the power cord and plug and wrap them well.
when you do not use the unit for a long period, take following steps to store the unit in good
condition;
Model
Rated Voltage
Rated Frequency
Power Consumption
Moisture Removal
(at 30 , 80%)
Operating Temperature
Weight
Tank Capacity 3.5L
ECO DC12
12L / DAY
LONG TERM STORAGE
SPECIFICATIONS
Eco Air guarantees this product free from defects in materials and workmanship for a period
of Two (2) years from the date of purchase. Coverage is valid only with proof of purchase.
This unit must be operated in the conditions recommended and at the voltage indicated .
Misuse or use in a dusty environment, along with attempts to service or alter the unit, will
render this WARRANTY VOID. The actual product may differ slightly from illustration.
For further information, please contact 0845 388 0007.
This product has been manufactured to comply with the EC Directives 2006/95/EC and
2004/108/EC.
SERVICE AND WARRANTY
TWO (2) YEAR LIMITED WARRANTY
Save This Warranty Information
ments
Copyright Reserved
WEE/EC2601UR
keeping your home
safe and clean
C149
This warranty is in addition to, and does not affect your statutory rights.
66129914992
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Ecoair ECO DC12 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI