- 2 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Power supply Ø, V, Hz
Cooling capacity kW
Btu/h
Heating capacity kW
Btu/h
Current Nominal running current A
Fan Motor type
Fan type
Motor output x Number of unit
Air flow rate CMM
(H/M/L) l/s
Capacitor μF/Vac
Drive
Coil Row x column x FPI mm
Dimensions (WxHxD)
Body mm(inch)
Weight Body kg(lbs)
Sound level (H/M/L) dB(A)+3
Piping Liquid mm(inch)
connections Gas mm(inch)
Dehumidification rate l/h
Safety devices
Temperature sensor
Referigerant
Referigerant control
Connectable outdoor unit
Power and transmission interunit cable No. x AWG
Model
AMNW09GAF11
[LMAN097HVP]
AMNW12GAF11
[LMAN127HVP]
Indoor unit type ART COOL
1, 208/230, 60 1, 208/230, 60
2.64 3.28
9,000 11,200
3.05 3.90
10,400 13,300
0.2 0.2
BLDC BLDC
Turbo fan Turbo fan
24 x 1 24 x 1
7.7/5.9/4.4 8.9/7.3/5.6
128/98/73 148/122/93
--
Direct Drive Direct Drive
2R x 20C x 21 2R x 20C x 21
600 x 600 x 147(23.6 x 23.6 x 5.8) 600 x 600 x 147(23.6 x 23.6 x 5.8)
14.5(32.0) 14.5(32.0)
39 / 35 / 31 42 / 38 / 34
6.35(1/4) 6.35(1/4)
9.52(3/8) 9.52(3/8)
1.20 1.40
Fuse, Thermal Protector for Fan Motor
Thermistor Thermistor
R410A R410A
EEV(in Outdoor unit or BD) EEV(in Outdoor unit or BD)
Multi F / F DX series Multi F / F DX series
4 x 18(Including Earth) 4 x 18(Including Earth)
Conversion Formula
kW = Btu/h × 0.0002931
CFM = CMM × 35.3
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7℃(80℉) DB / 19.4℃(67℉) WB
Outdoor 35℃(95℉) DB / 23.9℃(75℉) WB
- Heating Temperature : Indoor 21.1℃(70℉) DB / 15.6℃(60℉) WB
Outdoor 8.33℃(47℉) DB / 6.11℃(43℉) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased owing to ambient conditions during operation.