SPECIFICATION SHEET
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
B56 Series
B57 Series
B56 & B57 SERIES
RANGE HOODS
Gently curving glass or metal
canopy creates a dramatic,
contemporary appearance and an
open, airy feel.
FEATURES
Wall mount
Finish: 430 Stainless Steel #4 Brushed
Widths: 29-1/2”, 35-7/16”
Telescopic flue accommodates 8’ to 9’
ceilings
6” round duct connector/backdraft
damper
Convertible to non-ducted operation -
requires Model RK56 (sold separately)
Halogen lighting (2 x 20 watt, 12V, Type
JC 12V 20W G4 Base) (bulbs included)
5 push-button controls: blower on-off,
blower low speed, blower medium
speed, blower high speed, light on-off
Single centrifugal blower
Dishwasher-safe filter features a quick-
release latch
Cord-connected
OPTIONS
Replacement grease filters available
Flue extension for 10’ ceiling (Model
FXN56SS) (32-3/8” long) (ducted or
non-ducted)
Replacement non-ducted recirculating
filters available (Model ROUNDFILTER)
90C 99044484B
SPECIFICATIONS
VOLTS AMPS CFM SONES DUCT
120 3.3
450 (high) 8.5 (high)
6” round
200 (low) 2.5 (low)
HVI-2100 CERTIFIED RATINGS comply with new testing
technologies and procedures prescribed by the Home
Ventilating Institute, for off-the-shelf products, as they are
available to consumers. Product performance is rated
at 0.1 in. static pressure, based on tests conducted in
a state-of-the-art test laboratory. Sones are a measure
of humanly-perceived loudness, based on laboratory
measurements.
29-1/2”, 35-7/16”
19-3/4”
12”
10-7/8”
Min. 24” Ducted, 27“ Non-ducted (8-ft. ceiling)
Min. 36” Ducted / Non-Ducted (9-ft. ceiling)
Max. 30” Ducted / Non-Ducted (8-ft. ceiling)
Max. 41” Ducted / Non-Ducted (9-ft. ceiling)
19-3/4”
12”
10-7/8”
29-1/2”, 35-7/16”
Min. 24” Ducted, 27“ Non-ducted (8-ft. ceiling)
Min. 36” Ducted / Non-Ducted (9-ft. ceiling)
Max. 30” Ducted / Non-Ducted (8-ft. ceiling)
Max. 41” Ducted / Non-Ducted (9-ft. ceiling)
Broan-NuTone LLC Hartford, Wisconsin www.broan.com 800-558-1711
B56 & B57 SERIES WIRING
B56 & B57 SERIES MOUNTING
NOTES:
1. Minimum hood distance above cooktop must not be less than 30”.
A maximum of 36” above the cooktop is highly recommended for best capture of cooking impurities.
Distances over 36” above the cooktop are at the installer’s and user’s discretion - providing that ceiling height and flue length permit.
8¼”
MAX.
1. GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding
reduces the risk of electric shock by providing an escape wire for the electric current. This
appliance is equipped with a cord having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed and grounded.
2. Position the electrical outlet within the space covered by the decorative flue and
where it will not interfere with the round duct. Make sure the outlet is no further
than 8¼” from where the cord exits from the hood and that the outlet does not
interfere with a mounting bracket fastening area or where the decorative flue touches the wall.
C
L
1. Construct wood wall framing that is flush with interior surface of wall studs.
Make sure:
a) the framing is centered over installation location.
b) the height of the framing will allow the mounting bracket
to be secured to the framing within the dimensions
shown.
2. After wall surface is finished, carefully center and level the hood
mounting bracket and secure it to wall framing with (3) #8 x 1-1/2”
mounting screws. Tighten the screws completely.
NOTE:
On 8-ft. ceilings
Hood distance above cooktop is:
Minimum 30”, Maximum 36” (for ducted discharge)
Minimum 30”, Maximum 33” (for non-ducted discharge)
On 9-ft. ceilings
Hood distance above cooktop is:
Minimum 31”, Maximum 36” (for both ducted and non-ducted
discharge)
On 10-ft. ceilings
Hood distance above cooktop is:
Minimum 31”, Maximum 36” (for both ducted and non-ducted
discharge).
NOTE: 10-ft. ceilings require 10-ft. Flue Extension, Model FXN56SS
for ducted or non-ducted installations (purchase separately).
9
42
1
2” = bottom of hood 30” above cooktop
48
1
2” = bottom of hood 36” above cooktop
4
1
2
FRAMING BEHIND
DRYWALL
WALL STUDS
MOUNTING BRACKET
LOCATION
(ABOVE 36” HIGH
COOKTOP)
CEILING DUCT HOOD DISTANCE ABOVE 36” COOK TOP (SEE NOTE 1)
HEIGHT METHOD 30” 31” 32” 33” 34” 35” 36”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
8 FEET
DUCTED 42-1/2” 43-1/2”
44-1/2”
45-1/2”
46-1/2”
47-1/2”
48-1/2”
NONDUCTED 42-1/2” 43-1/2”
44-1/2”
45-1/2”
9 FEET DUCTED OR 43-1/2” 44-1/2” 45-1/2” 46-1/2” 47-1/2” 48-1/2”
NONDUCTED
10 FEET DUCTED OR
NONDUCTED 43-1/2” 44-1/2” 45-1/2” 46-1/2” 47-1/2” 48-1/2”
WITH FXN56SS
1
9
16
/