Essick H12 400HB Owner's manual

Category
Dehumidifiers
Type
Owner's manual
OWNERS
CARE
&
USE
MANUAL
EVAPORATIVE
HUMIDIFIER
MODELS:
H12 Series
H12 300HB, LT OAK
H12 400HB, OAK BURL
• Automatic Humidistat
• Automatic Shutoff
4-Speed fan
Rotary control with digital readout
• Quiet Setting for Night-time use
• Easy to clean, removable power pack
SAVE THE ENVIRONMENT
RECYCLE APPROPRIATE MATERIALS
To order parts and accessories call
1-800-547-3888
French and Spanish
Instructions included.
Se incluyen instrucciones
En Español y Francés.
Directives en Français et en
espagnol compris
1B72300 2/2012 Printed in China
READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFEGUARDS
READ BEFORE USING YOUR HUMIDIFIER
1. This appliance has a polarized plug (one blade is wider than the
other). To reduce the risk of electric shock, this plug is intended to fit
into a polarized 120-volt AC, 15 amp outlet, and only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician. Do not attempt to defeat this safety
feature. If an extension cord must be used, it should also accept the
wide blade plug and meet this electrical rating.
2. Do not place the cord under rugs, near loose drapes, in traffic areas,
nor near heat sources or combustible materials.
3. Do not use the humidifier if the cord is damaged.
4. Always unplug the power cord before filling, cleaning,
servicing, or when the unit is not in use.
5. This humidifier is ETL listed with Essick Air brand evaporative wicks
in place.
6. It is very important that cleaning solutions such as bleach, anti-
bacteria treatment or descaler, which could be used to clean the
cabinet, are not sprayed or applied to the chassis assembly. These
solutions can cause serious electrical malfunction of the humidifier.
INTRODUCTION
Your Essick Air evaporative humidifier adds invisible moisture to your
home by moving dry inlet air through a saturated wick. As air moves
through the wick, the water evaporates into the air, leaving behind any
white dust, minerals, or dissolved and suspended solids. Because the
water is evaporated, there is no messy mist or spray and no white dust,
just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its
ability to absorb and evaporate water decreases. We recommend
changing the wick at the beginning of every season. In hard water
areas, more frequent replacement may be necessary to maintain your
humidifier’s efficiency.
Use only Essick Air brand replacement wicks and chemicals.
To order parts, wicks and chemicals call 1-800-547-3888. The H12 Series
humidifiers use Essick Air wick #1045. Only the Essick Air evaporative
wick guarantees the certified output of your humidifier. Use of wicks other
than Essick Air brand will void your warranty as well as the certification of
output and may reduce the efficiency and output of your humidifier.
CAUTION: Do NOT position the unit directly in front of a hot air duct
or radiator. Do NOT place on soft carpet.
3
HOW YOUR HUMIDIFIER WORKS
ASSEMBLY, CONTROLS & OPERATION
1. Remove the packaging from the top of the humidifier.
2. Lift off the water bottle cover (left-hand side). Remove the water bottle, lift
off the chassis/power pack and then remove the humidifier cabinet from
the carton.
3. Remove the evaporative wick, float assembly (black rod with white float),
and all of the remaining packaging materials from the cabinet. Check to
see that you have all of the following items removed from the boxes
accessory kit and cabinet before discarding the packaging:
CASTERS
4. Turn the emptied cabinet upside down. Insert each caster stem into the
four caster holes on each corner of the humidifier bottom. The casters
should fit snugly and be inserted until the stem shoulder reaches the
cabinet surface.
5. Turn the cabinet right side up.
EVAPORATIVE WICK
6. When placing the wick back into the humidifier, the rod and float assembly
must also be reattached. Insert the top of the float rod through the hole on
the extended wick retainer (attached to the top of the wick frame)
Dry air is drawn into the
humidifier though the
back and moisturized as
it passes through the
evaporative wick. It is
then fanned out into the
room.
LEGEND:
1. Water bottle
2. Chassis/power pack
(motor/fan assembly)
3. Evaporative wick
4. Water reservoir
5. Dry room air intake
6. Moist air output
Filler hose ♦ Caster kit
♦ Bacterial treatment sample ♦ Water bottle with cap
♦ Optional AirCare® Filter (purchased separately) Manual
4
7. Holding the float in place, lower the wick and float assembly together into the
cabinet. The wick has a mounting rib on the top edge which hooks over a rib
at the inside back of the cabinet.
NOTE: The float rod retainer must be
extended prior to inserting the float rod. The
white float must be positioned into the pocket
in the bottom of the cabinet.
IMPORTANT FILLING INFORMATION
8. Your humidifier is equipped with one water
bottle. When both the water bottle and
reservoir have emptied, the humidifier fan
will automatically shut off, but will start
again automatically when the water bottle
and reservoir are refilled.
9. When the bottle is being filled for the first time and the
wick is still dry, it will take approximately 20 minutes
to drain the bottle into the reservoir. After the bottle
has emptied, it should be refilled again to obtain
maximum running time.
10. When refilling the bottle and the wick is still wet, it will
take approximately 12 minutes to refill the reservoir.
At this time, you should refill the bottle for maximum
running time.
11. Fill the bottle water. If you only have softened water
available in your home, you can use it, but you will
notice a buildup of minerals on the wick much sooner.
The bottle holds 2.5 gallons. When filling, be careful
not to pressurize it by overfilling. Bottle damage can
result from this. A fill hose is provided with your
humidifier which will fit most faucets. Place the water bottle into the left side
of the humidifier with the valve cap end down, so that the groove in the water
bottle faces the inside. Replace the water bottle cover.
NOTE: We recommend using Essick Air Bacteriostat treatment when you refill the
water bottle to eliminate bacterial growth. Add bacteriostat according to the
instructions on the bottle and then tighten the valve cap on your water bottle.
NOTE: For optimum running time, fill the water bottle, tighten the cap, and place
inside unit, allowing it to completely drain into the water reservoir. Then refill the
bottle and replace in the cabinet. Do not fill the reservoir bucket, as overfilling will
result in water damage. Use only the bottle provided.
CHASSIS/POWER PACK
Place the chassis/power pack unit into the
cabinet, so it fits without tipping or rocking.
OPTIONAL AIRCARE® FILTER
The first stage of the air filter is a high-
efficiency, electrostatically charged filter media
which traps dust, pollen, and airborne
pollutants. The second stage is an activated
carbon media which absorbs odors from
cooking, pets, or tobacco smoke. We
recommend replacing the AirCare® filter at least once a year and more often if
necessary. When the white filter media is coated with a layer of dust and dirt, it is
time to replace the AirCare® filter. The certified water output of your humidifier will
5
be reduced when using the AirCare® filter. AirCare® filters are optional and are not
required for normal operation of the humidifier. AirCare® is registered trademark of
Essick Air Products.
12. The AirCare® filter has four tangs that engage into four keyhole slots that mount
the AirCare® filter onto the outside of the back of the cabinet.
OPERATION
1. Plug cord into wall
receptacle. Your
humidifier is now
ready for use. The
humidifier should be
placed at least FOUR
inches away from any
walls and away from
heat registers.
Unrestricted airflow
into the unit will result
in the best efficiency
and performance.
2. Push in on the lower knob to turn the unit on.
Fan Speed:
3. Rotate the fan speed knob clockwise to increase the fan speed. The speed
settings ( 1 4) will be shown on the LED display.
NOTE: When excessive condensation exists, a lower speed setting is recommended.
Humidity Level:
NOTE: Each model has an automatic humidistat with settings from 25-65%. The
humidistat will turn the humidifier on when the humidity in your home is below the
humidistat setting and will turn the humidifier off when the humidity reaches the
humidistat setting. When set at 65%, the humidifier will operate continuously.
4. For initial operation, set the humidity knob at a midpoint setting (45-50% is
recommended) and adjust up or down from there to achieve the desired
humidity level. The digital display will show the desired setting momentarily,
and then revert to displaying the actual humidity.
Control Panel Displays:
Several functions of the humidifier can be monitored through the LED display on
the control panel.
Refill Indication:
1. The letter F on the display indicates when the unit is entirely out of water. The
motor will cut off at this point.
Filter Indication:
2. The filter’s condition is critical to the humidifier’s effectiveness. A check filter
function (CF) will display every 720 hours of operation to remind the user to
check the condition of the filter. Water condition significantly affects the life of
a wick, so replacement of wick may be required more often if hard water
conditions exist.
3. Replace the filter as necessary per instructions on page 4.
4. To reset the CF function, or when replacing the filter, unplug the unit for 1-2
minutes and then reconnect it to power.
6
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille
dry at all times.
CARE AND MAINTENANCE
Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal
growth. Ordinary household bleach is a good disinfectant and can be used to
wipe out the humidifier base and bottle/reservoir after cleaning. We recommend
cleaning your humidifier at least once every two weeks to maintain optimum
environmental conditions for your home.
We also recommend using Essick Air Bacteriostat Treatment each time you refill
your humidifier to eliminate bacterial growth. Add bacteriostat according to the
instructions on the bottle. Please call 1-800-547-3888 to order Bacteriostat
Treatment reference part number 1970.
1) Turn off unit completely counterclockwise and unplug from outlet.
2) Lift out the water bottle and the power pack.
3) Carry bottle and base to cleaning basin. Lift wick with float assembly from
the base allowing the water to drain and remove float assembly from wick.
Rinse wick under freshwater only. Do not use soap, detergent, or any other
cleaners on the wick. Leave in sink to drain.
REMOVING SCALE
4) Empty the water from the reservoir and water bottle. Fill both reservoir and
water bottle ½ full with water and add 8 oz. (1 cup) of white vinegar to each.
Let stand 20 minutes. Then empty solution.
5) Dampen a soft cloth with white vinegar and wipe out reservoir to remove
scale. Rinse the water bottle and reservoir thoroughly with fresh water to
remove scale and cleaning solution before disinfecting.
DISINFECTING UNIT
6) Fill the water bottle and reservoir ½ full with water and add 1 teaspoon of
bleach to each. Wet all surfaces on water bottle and cabinet. Let solution
stay for 20 minutes, then rinse with water until bleach smell is gone. Dry with
clean cloth. The outside of the unit and water bottle may be wiped down with
a soft cloth dampened with fresh water.
7) Refill unit and re-assemble per ASSEMBLY instructions.
SUMMER STORAGE
1) Clean unit as outlined in Care & Maintenance section.
2) Discard used wick and any water in the reservoir or bottle and allow to dry
thoroughly before storage. Do not store with water inside reservoir or bottle.
3) Do not store unit in an attic or other high-temperature area, as damage will
occur.
4) Install new filter at beginning of season.
7
Trouble
Probable Cause
Remedy
Unit does not operate on any
speed setting
No power to unit.
Ensure polarized plug is fully inserted
in wall outlet.
Unit has run out of water fan
will not operate without water is
present.
Refill water bottle.
Refill switch operation/improper
positioning of float assy.
Ensure float assembly is correctly
positioned as described in
“Important Filling Instructions”, page 4.
Motor does not Turn On.
Check motor/fan operation.
CAUTION: Do not touch the fan
when accomplishing this test, as
the motor may turn on.
To test the motor, turn unit ON and
turn all dials fully ON.
Turn the chassis over and insert
finger into tab where float rod is
supposed to go. If fan turns on, the
fan and motor are working
correctly.
Water not draining into
reservoir
Water bottle incorrectly
positioned.
Unplug unit. Remove water bottle
and reassemble without water
bottle. Turn on and see if fan
comes on. If so, replace water
bottle and continue operation.
If unit has overheated, motor
temp-sensing fuse may have
tripped.
Take unit to authorized service
station. DO NOT ATTEMPT
electrical repairs yourself.
Not enough humidity.
Wick is old and ineffective.
Humidistat is not set high
enough
Replace wick when clogged or
hardened with minerals.
Increase humidity setting on control
panel.
Too much humidity.
(condensation becomes heavy
on fold surfaces in room)
Humidistat is set too high.
Reduce humidistat setting or
increase room temperature.
Water leak
Water reservoir may have been
overfilled. Or bottle may be
releasing too much water.
DO NOT OVERFILL bottle and
reservoir. DO NOT puncture bottle
to make bottle drain faster.
Odor
Bacteria may be present.
Clean and disinfect cabinet following
Care and Maintenance instructions.
Add Essick Bacteria Treatment
According to instructions on the
bottle.
It may be necessary to replace the
wick if odor persists.
8
ESSICK AIR PRODUCTS
HUMIDIFIER WARRANTY POLICY
EFFECTIVE APRIL 1, 2010
SALES RECEIPT REQUIRED AS PROOF OF PURCHASE
FOR ALL WARRANTY CLAIMS.
This product is warranted against defects in workmanship and materials as listed below:
One year from the date of sale on factory installed components.
Two years from the date of sale on motor.
Thirty (30) days on replacement components.
This warranty does not apply to filters or wicks which are customer replaceable parts.
This warranty applies only to the original purchaser of the product when it is purchased from a
reputable retailer/dealer.
This warranty does not apply to damage from accident, misuse, alterations, unauthorized repairs,
unauthorized use, mishandling, unreasonable use, abuse, including failure to perform reasonable
maintenance, normal wear and tear, nor where the connected voltage is more than 5% above
the nameplate voltage, nor to the equipment or products being improperly installed or wired or
maintained in violation of this Owner’s Manual.
Alterations include the substitution of name brand components including, but not limited to wicks
and bacteria treatment.
THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS THE SOLE AND
EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS
AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN LIEU OF AND EXCLUDES ALL
OTHER WARRANTIES AND CONDITIONS, EXPRESS OR IMPLIED, ARISING BY
OPERATION OF LAW OR OTHERWISE. INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE.
No employee, agent, dealer or other person is authorized to give any warranties or conditions on
behalf of the manufacturer. The customer shall be responsible for all costs incurred in the
removal or reinstallation and shipping of the product for repairs.
Within the limitations of this warranty, purchaser with inoperative units should contact
customer service @ 800-547-3888 for paperwork and instructions on the return of the unit
for repair.
Notice:This warranty will be null & void if purchaser attempts to repair or replace any
parts which are mechanical or electrical.
A copy of the sales receipt is required before authorization to return a unit for repair is approved.
The manufacturer will repair or replace the product, at its discretion, with return freight paid by
the manufacturer. It is agreed that such repair or replacement is the exclusive remedy available
from the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY LAW, THE
MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR REVENUES.
The warranty gives the customer specific legal rights, and the customer may also have other
rights which vary from province to province, or state to state.
18
Intentionally left blank
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Essick H12 400HB Owner's manual

Category
Dehumidifiers
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI