6 Manual Operation
on the following pages when retrotting a new metering pump onto an
older biological unit with no power supply.
3. Retrotting water treatment unit for new metering pump (This covers
Bio units, consult factory for WTA units):
WARNING: ENSURE POWER IS DISCONNECTED FROM
WATER TREATMENT UNIT BEFORE MAKING ANY WIRING
CHANGES.
a. Removing old metering pump components:
i. Unwire old metering pump from control panel.
ii. Remove old metering pump from tank or tank stand,
disconnect tubing from tank and remove pick-up tube from
chemical. Leave tank ttings.
iii. Unwire and remove existing single fuse holder from control
panel, labeled F13. Leave black wire that was attached to
top of fuse hold loose for now. (Some units may not have
a fuse holder, consult factory with questions.)
b. Installing New Metering pump:
i. Mount new pump using the left hanger brackets and one of
the old pump holes on the tank with the supplied hardware.
ii. Level pump, mark spot for second hole through hanger
bracket.
iii. Drill 3/16” hole and insert hardware through hole and
hanger bracket. Tighten all bolts.
iv. Run power cord through open strain relief in control panel.
v. On inside of the front panel of the control box, run a wire
from terminal spade 2 on the peristaltic pump switch to
terminal spot 031. (This can be done by moving the Blk/
F13 wire from the bottom of the old fuse holder to terminal
031).
vi. Place power supply on open din rail location, placing in
location of old fuse holder works well.
vii. Run black wire from terminal strip spot 122 to L on the
power supply.
viii. Run white wire from terminal strip spot 202 to N on the
power supply.
ix. Run white pump wire to the + terminal of power supply and
black pump wire to – terminal of power supply. See Photo
on following page:
x. If wiring in 2 pumps, place both white wires in the + terminal
and both black wires in the – terminal.
INSTALLATION