Step 6
Step 3
Step 3
Step 4
Step 7
Step 7
Step 10
Step 11
Step 12
Step 9
Step 13
Step 1
Step 2
Step 8
Step 8
Step 9
Step 5
Step 5
C. Diagram (DDG panel, draw tube and internal bearing disassemble procedure)
Step 1: release LOCK knob tension counterclockwise
Step 2: release Hex Screw (M5) counterclockwise
Step 3: release Half Round Screw counterclockwise (2 pcs.)
Step 4: carefully take out DDG panel (1 unit)
Step 5: draw the gradual tube to 40mm position until all 4 pcs. Half Round Screw appears and then released all screws
completely counterclockwise. (Temporary store away for assembly later).
Step 6: pull the whole draw tube outward (temporary store away for assembly later).
Step 7: release Hex Screw (M4) counterclockwise (2 pcs.)
Step 8: release Hex Screw (M4) counterclockwise (2 pcs.)
Step 9: release bearing holder
clockwise
(4 holders) Note: replace bearing holder only if it has problem. *Counterclockwise
to assemble bearing holder.
Step 10, 11, 12: carefully remember the factory setting for assembly or replacement
Step 13: check if gradual sensor has any damage or need replacement. Note: make sure gradual sensor sits perfectly flat
on draw tube before DDG panel can properly function.
Step 14: follow steps 12 through step 1 for assemble procedure. Note: make sure every step is properly installed before
moving to next step.
4 reminders to watch for:
1. Make sure every steps is carefully examine before installation
2. All screws and bearing holders must be properly install
3. Step 7 and 8 must be properly balanced on both sides before installation. (M4)
4. Step 2 please do not over power and please adjust with caution.