Morningstar SunSaver MPPT Quick start guide

  • Hello! I am an AI chatbot trained to assist you with the Morningstar SunSaver MPPT Quick start guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Optional Accessories:
Quick Start Guide
14
Specifications:
Operational Configuration:
SS-MPPT-15L
NominalBatteryVoltage
12Vor24V
Max.SolarInputVoltage 60V
NominalMaximumInputPower 200W/400W
MaximumBatteryCurrent 15A
BatteryVoltageRange
736V
©2021MorningstarCorporation.AllRightsReserved. MS003294SSMPPTQSG(3/16/2021)RevC03
In the Box:
Mounting
Screws(x4)
Tools Required:
#2PhilipsScrewdriver
3/16(5mm)&3/32"(2.5mm)FlatheadScrewdriver
Drillwitha3/32"(2.5mm)bit
Multimeter
RemoteMeter(RM1)
EthernetMeterBus
Converter(EMC1)
Safety Information:
WARNING: Shock Hazard
TheSunSaverMPPTcontrollermustbeinstalledbya
qualifiedtechnicianinaccordancewiththeelectrical
regulationsofthecountryofinstallation.
WARNING: Shock Hazard
ThisunitisnotprovidedwithaGFDIdevice.Thischarge
controllermustbeusedwithanexternalGFDIdeviceas
requiredbytheArticle690oftheNationalElectricalCode
fortheinstallationlocation.
IMPORTANT: READtheSunSaverMPPTInstallation
Manualforsafetyandregulatoryinformation,
instructionsonconfigurationandoperation,and
wa
rrantyinformation.
RemoteTemperature
Sensor(RTS)
Scan QR Code to go
directly to the
SunSaver MPPT
Installation Manual
and warranty
information online.
Contact Information:
TechnicalSupport:Support.morningstarcorp.com
Phone:12153214457
SunSaverMPPT
ChargeController
WarrantyRegistration:https://www.morningstarcorp.com/productregistration/
1
ForCustomProgramming:
Usethesoftwareavailableathttps://www.morningstarcorp.com/msview/.
SeetheSunSaverMPPTInstallation,Operations,andMaintenanceManualfor
additionalinformation/guidance.
PCMeterBusAdapter
(MSC)
USBCommunicationsAdapter
(UMC1)
BatterySelectJumper
INSERTED
BatterySelectJumper
REMOVED
Switch 1: Battery Type
Gel
1
Sealed
AGM
1
Flooded
Switch 2: Load Control /
Low Voltage Disconnect/Reconnect
LVD=11.5V
LVR=12.6V
LVD=11.0V
LVR=12.1V
DIP
Switches
Switch 3: Auto-Equalization
AutoEqualizeOFF
AutoEqualizeON
(AGM,FloodedBatteryTypesonly)
Switch 4: Communication Mode -
Meter/MODBUS®
RemoteMeter,&
RelayDriver
MODBUS®Protocolfor
MSView,EthernetMeterbus
Converter,3
rd
PartyDevices
DIP
Switches
Top
ONOFF
ONOFF
ON
2
OFF
ONOFF
ONOFF
1
Setpointsforthisswitchsettingcanbemodifiedwithcustomprogramming.
2
Thesevaluescanbemodified
withcustomprogramming.
RatedLoadCurrent 15A
BATTERY SET POINTS
12-volt (24-volt)
Set Point GEL
AbsorptionVoltage
FloatVoltage
TimeuntilFloat
EqualizeVoltage
14.0V
(28.0V)
13.7V
(27.4V)
3hours
N/A
Sealed
14.1V
(28.2V)
13.7V
(27.4V)
3hours
N/A
EqualizeDuration
EqualizeCalendar(days)
MaximumRegulationVoltage*
N/A
N/A
15V(30V)
N/A
N/A
LVD**/LVR**(Switch2OFF)
LVD**/LVR**(Switch2ON)
LoadHVD**
11.5V/12.6V@12V(23.0V/25.2V@24V)
11.0V/12.1V@12V(22.0V/24.2V@24V)
15.3V(30.6V)
LoadHVR**
ArrayHVD(Temp.Comp.)
ArrayHVR(Temp.Comp.)
14.5V(29V)
Highestvoltagesetpoint+0.5V
13.8V(27.6V)
AGM
14.3V
(28.6V)
13.7V
(27.4V)
3hours
14.5V
Flooded
14.4V
(28.8V)
13.7V
(27.4)
3hours
14.9V
3hours
28
3hours
28
*Nottemperaturecompensated.15V@12Vnominal,30V@24Vnominal.
**
AdjustablebyDIPSwitch2.Nottemperaturecompensated.Canbemodifiedin
customsettings.
Bottom
DIP
Switches
RelayDriver(RD1)
32
SunSaver MPPT™ Charge Controller
Quick Start Guide
(+)
(–)
(+)
(–)
Solar Disconnect*
(PV GFP required per
NEC 690)
Photovoltaic (PV) Array
Battery / Battery Bank
Battery
Disconnect*
DC Load
Disconnect*
Remote
Temperature
Sensor
RJ11
Cable
Power UP Sequence:
1. ConnectBattery/BatteryBank.
2. ConnectSolar.
Power DOWN Sequence:
1. DisconnectSolar.
2. DisconnectBattery/BatteryBank.
Mounting:
#2
Minimum
Clearance
Requirements:
CAUTION: Equipment Damage
DonotexposetheSunSaverMPPTtoweather.Locateinadry,
protectedareatopreventequipmentdamage.Ensurethe
minimumclearancerequirementsarefollowedtoprovide
adequateventilationandpreventtheunitfromoverheating.
IMPORTANT: Exampleonly.Actualwiringmayvary.READtheSunSaver
MPPTInstallation,Operations,andMaintenanceManualformandatory
safetyrequirements.Allconfigurationmustcomplywithlocalandnational
electriccodes.Consultyourlocalelectricauthoritytoensurecompliance.
Negative (–)
Positive (+)
Ground
SeetheMorningstarPVStringCalculatorat:
http://stringcalculator.morningstarcorp.com/
Component
LoadTerminals
WireSize
(Solid)
#6AWG
16mm
2
(Maximum)
ToolRequired
3/16"(5mm)
FlatheadScrewdriver
BatteryTerminals
Wiring and Torque Requirements
Torque
(Maximum)
10.6inlbs.
(1.2Nm)
SolarTerminals
Securinghardware
notshown.
WARNING: Explosion Hazard
NeverinstalltheSunSaverMPPTinanenclosurewith
vented/floodedbatteries.Batteryfumesareflammable
andwillcorrodeanddestroytheSunSavercircuits.
Step 1: Choose Mounting Location
LocatetheSunSaverMPPTonaverticalsurface
protectedfromdirectsun,hightemperatures,andwater.
Step 2: Check for Clearance and Ventilation
PlacetheSunSaverMPPTinthelocationwhereitwillbe
mounted.Verifythatthereissufficientroomtorunwires
andthatthereisampleroomaboveandbelowthe
controllerforairflow.
Step
3: Mark Holes
Useapencilorpentomarkthefour(4)
mountingholelocationsonthemountingsurface.
Step 4: Drill Holes
Removethecontrolleranddrill3/32”(2.5mm)
holesinthemarkedlocations.
Step 5: Secure Controller
Placethecontrolleronthesurfaceandalignthemounting
holeswiththedrilledholesinstep4.Securethecont
roller
inplaceusingtheMountingscrews(included).
3/32"(2.5mm)
Battery(+)
Battery(—)
Optional Accessories
RemoteMeter
(RM1)
Ethernet
MeterBus
Converter
PCMeterBus
Adapter(MSC)
USB
Communications
Adapter(UMC1)
2
RemoteTemperature
Sensor
#22AWG/0.3mm
2
(Minimum)
#12AWG/3.0mm
2
(Maximum)
3/32"(2.5mm)
FlatheadScrewdriver
3.5inlbs.
(0.4Nm)
WireSize
(multistrand)
#6AWG
16mm
2
(Maximum)
WireSize
(finestrand)
#8AWG
10mm
2

(Maximum)
Recommended
Orderof
Installation
1
2
3
4
4
DC Load(s)*
CommunicationsSecurity
Lighting
Industrial
Residential
PrimarySystem
Ground
3
1
6"
6"
2"
2"
FusesorDisconnects
*Fuseorbreakersizingmustbebasedonrequiredwireampacity.
Ifusingafuse,doNOTinsertthefuseinthefuseholderuntilafteralltheother
connectionshavebeencompleted.
5
(+)
(–)
12VdcModule 12VdcModule
60VocMaximum
WARNING: Risk of Fire
IfaRemoteTemperatureSensor(RTS)isNOTconnected,
locatetheSunSaverMPPTwithin3m(10ft)ofthebatteries.
InternaltemperaturecompensationwillbeusediftheRTSis
notconnected.UseoftheRTSisstronglyrecommended.
WARNING: Shock Hazard
Fuses,circuitbreakers,anddisconnectswitchesneveropengrounded
systemconductors.OnlyGFDIdevicesarepermittedtodisconnect
groundedconductors.
5
5
STATUS LED
None
Green
Red
Red
Indication
Operating
State
Color
OFF(withheartbeat
1
)
ONSolid(withheartbeat
2
)
Flashing
ONSolid(withheartbeat
2
)
Night
Charging
Error
CriticalError
StatusLED BatterySOCLEDs
¹heartbeatindicationflickerstheStatusLEDON brieflyevery5seconds
2
heartbeatindicationflickerstheStatusLEDOFF brieflyevery5seconds
IMPORTANT:
ArrayVoltageshouldNEVERexceed
themaximuminputvoltage.
BATTERY STATE-OF-CHARGE (SOC) LEDs
Green
Green
Green
Green
Indication
Battery
Status
SOC
LED
FastFlashing(2Flash/sec)
MediumFlashing(1Flash/sec)
SlowFlashing(1Flash/2sec)
ONSolid
EqualizeCharge
Absorption
Charge
FloatCharge
NearlyFull
Load Status
LoadON
LoadON
LoadON
LoadON
Yellow
Red
Red
ONSolid
Flashing(1Flash/sec)
ONSolid
HalfFull
BatteryLow
BatteryEmpty
LoadON
LVDWarning
(LoadOn)
LVD(LoadOff)
LEGEND
WARNING: Shock Hazard
Testbetweenallterminalsandgroundbeforetouching.
PoweroraccessoryterminalsareNOTelectricallyisolatedfromDCinput
andmaybeenergizedwithhazardoussolarvoltage.
IMPORTANT:
Ensurethereisonly1 DCNegativetoGroundBondintheentiresystem.
RelayDriver
(RD1)
/