Miller Big Blue 600D Owner's manual

Category
Engine
Type
Owner's manual

This manual is also suitable for

cover 5/94 ST-134 686-C PRINTED IN USA
© 1994 MILLER Electric Mfg. Co.
Read and follow these instructions and all
safety blocks carefully.
Have only trained and qualified persons
install, operate, or service this unit.
Call your distributor if you do not understand
the directions.
Give this manual to the operator.
For help, call your distributor
or: MILLER Electric Mfg. Co., P.O. Box 1079,
Appleton, WI 54912 414-734-9821
OWNER’S
MANUAL
August 1994 Form: OM-481C
Effective With Serial No. KE706649
CC/CV, DC Welding Generator
For SMAW, GMAW, FCAW, SAW Welding And CAC-A
600 Amps, 44 VDC At 100% Duty Cycle
Deutz F4L912 Air-Cooled, Diesel Engine
3kVA/kW AC Auxiliary Power With Overload Protection
Automatic Shutdown For Low Oil Pressure, High Oil Temperature, Or
Cooling System Failure
For Options And Accessories, See Rear Cover
Big Blue® 600D
OM-481C 8/94
EMF INFORMATION
The following is a quotation from the General Conclusions Section of
the U.S. Congress, Office of Technology Assessment, Biological
Effects of Power Frequency Electric & Magnetic Fields
Background Paper, OTA-BP-E-53 (Washington, DC: U.S.
Government Printing Office, May 1989): “. . . there is now a very large
volume of scientific findings based on experiments at the cellular
level and from studies with animals and people which clearly
establish that low frequency magnetic fields can interact with, and
produce changes in, biological systems. While most of this work is
of very high quality, the results are complex. Current scientific
understanding does not yet allow us to interpret the evidence in a
single coherent framework. Even more frustrating, it does not yet
allow us to draw definite conclusions about questions of possible risk
or to offer clear science-based advice on strategies to minimize or
avoid potential risks.”
To reduce magnetic fields in the workplace, use the following
procedures:
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around the body.
4. Keep welding power source and cables as far away as practical.
5. Connect work clamp to workpiece as close to the weld as
possible.
About Pacemakers:
The above procedures are among those also normally
recommended for pacemaker wearers. Consult your doctor for
complete information.
Considerations About Welding And The Effects Of Low Frequency Electric And
Magnetic Fields
NOTE
mod10.1 4/93
TABLE OF CONTENTS
SECTION 1 SAFETY INFORMATION 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 SPECIFICATIONS 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Volt-Ampere Curves 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Duty Cycle 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Fuel Consumption 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. AC Auxiliary Power 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 INSTALLATION 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Selecting A Location And Moving Welding Generator 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Installing Exhaust Pipe And Rain Cap 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Connecting The Battery 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Lower Front Panel 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Generator Auxiliary Power System 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Engine Prestart Checks 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. Selecting And Preparing Weld Output Cables 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Connecting To Weld Output Terminals 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-9. Remote 14 Receptacle Or Terminal Strip Information And Connections 11. . . . . . . . . . . . . . . .
3-10. Installing Optional Ether Cylinder 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 OPERATING THE WELDING GENERATOR 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 OPERATING AUXILIARY EQUIPMENT 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-1. 120 Volt Duplex Receptacles 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Optional 240 Volt Duplex Receptacle 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 MAINTENANCE & TROUBLESHOOTING 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-1. Routine Maintenance 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Maintenance Lights 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3. Oil And Fuel System Components 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Servicing Air Cleaner 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-5. Adjusting Engine Speed 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-6. Checking Battery Voltage Or Replacing Battery 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 MAINTENANCE & TROUBLESHOOTING (Continued)
6-7. Jump-Starting Welding Generator 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-8. Overload Protection 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-9. Checking And Replacing Alternator Belt 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-10. Optional Ether Starting Aid Maintenance 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-11. Optional Spark Arrestor Inspection And Cleaning 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-12. Optional Overspeed Shutdown Valve Adjustment 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-13. Troubleshooting 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 7 ELECTRICAL DIAGRAMS 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 RUN-IN PROCEDURE 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Run-In Procedure Using Load Bank 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-2. Run-In Procedure Using Resistance Grid 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 AUXILIARY POWER GUIDELINES 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-1. How Much Power Does Equipment Require? 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-2. How Much Power Can Generator Supply? 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-3. Typical Connections To Supply Standby Power 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9-4. Selecting Extension Cord 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 10 PARTS LIST 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10-1. Main Assembly 48. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10-2. Panel, Front w/Components 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10-3. Panel, Front Lower w/Components 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10-4. Control Box 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 10-5. Generator 57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Equipment 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-481 Page 1
SECTION 1 SAFETY INFORMATION
mod1.1 2/93
Read all safety messages throughout this manual.
Obey all safety messages to avoid injury.
Learn the meaning of WARNING and CAUTION.
1 Safety Alert Symbol
2 Signal Word
WARNING means possible death
or serious injury can happen.
CAUTION means possible minor
injury or equipment damage can
happen.
3 Statement Of Hazard And Re-
sult
4 Safety Instructions To Avoid
Hazard
5 Hazard Symbol (If Available)
6 Safety Banner
Read safety blocks for each sym-
bol shown.
7 NOTE
Special instructions for best oper-
ation not related to safety.
2
NOTE
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Disconnect input power before
installing or servicing.
WARNING
READ SAFETY BLOCKS at start of
Section 3-1 before proceeding.
WARNING
5
4
6
7
1 2
CAUTION
MOVING PARTS can injure.
Keep away from moving parts.
Keep all panels and covers closed
when operating.
3
Turn Off switch when using high frequency.
Figure 1-1. Safety Information
SECTION 2 SPECIFICATIONS
Table 2-1. Welding Generator
Specification Description
Type Of Output Constant Current/Constant Voltage (CC/CV), Direct Current (DC)
Rated Weld Output 600 Amperes, 44 Volts DC At 100% Duty Cycle (See Section 2-2)
Amperage Range 45-800 A
Max. Open-Circuit Voltage 95 Volts DC
Welding Processes Shielded Metal Arc (SMAW), Gas Metal Arc (GMAW), Flux Cored Arc (FCAW), And Submerged Arc
Welding (SAW); Air Carbon Arc Cutting and Gouging (CAC-A)
Auxiliary Power Rating Single-Phase, 3 kVA/kW, 120/240 Volts AC, 26 Amperes, 60 Hz
Engine Deutz F4L912 Air-Cooled, Diesel Engine
Engine Speed (No Load) Weld/Power Speed: 1850 rpm
Fuel Tank Capacity 19 gal (72 L)
Overall Dimensions See Figure 3-2
Weight Net: 2250 lb (1021 kg); Ship: 2380 lb (1080 kg)
OM-481 Page 2
2-1. Volt-Ampere Curves
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of
other settings fall between the
curves shown.
rsb1.1 10/91 SB-133 004 / SB-133 003
A. For Constant Current (CC) Mode B. For Constant Voltage (CV) Mode
Figure 2-1. Volt-Ampere Curves
2-2. Duty Cycle
CAUTION
WELDING LONGER THAN RATED DUTY CYCLE can damage unit and void warranty.
Do not weld at rated load longer than shown below.
warn7.1 8/93
Duty Cycle is percentage of 10
minutes that unit can weld at
rated load without overheating.
Continuous Welding
sb1.1 8/93 SB-134 397-A
0
10
Minutes
100% Duty Cycle At 600 Amperes
Definition
Chart
Figure 2-2. Duty Cycle
OM-481 Page 3
2-3. Fuel Consumption
The fuel consumption curve shows
typical fuel use under weld or power
loads.
rsb2.1 10/91 SB-133 838
Figure 2-3. Fuel Consumption Curve
2-4. AC Auxiliary Power
The ac power curve shows the auxil-
iary power in amperes available at
the 120 and optional 240 volt
receptacles.
rsb3.1* 2/92 SB-109 365-B
Figure 2-4. AC Power Curve For 120 And 240 Volt Duplex Receptacles
OM-481 Page 4
SECTION 3 INSTALLATION
3-1. Selecting A Location And Moving Welding Generator
WARNING
ENGINE EXHAUST GASES can kill.
Do not breathe exhaust fumes.
Use in open, well-ventilated areas, or vent exhaust
outside and away from building air intakes.
ENGINE EXHAUST SPARKS can cause
fire.
Use only U.S. Forestry Department approved spark
arrestor and comply with all local, state, and federal
laws.
A spark arrestor is mandatory in all National Forests
and in grass, brush, or forest covered lands in
California, Oregon, and Washington. Check with
state and local authorities in other areas.
Properly maintain the spark arrestor.
Stop engine and allow exhaust system to cool down
before servicing spark arrestor.
Service spark arrestor away from flammables.
HOT ENGINE EXHAUST AND EXHAUST
PIPE can cause fires.
Keep exhaust and pipe away from flammables.
FALLING EQUIPMENT can cause
serious personal injury and equipment
damage.
Use lifting eye to lift unit only, NOT running gear, gas
cylinders, trailer, or any other heavy options,
accessories, or devices.
Use equipment of adequate capacity to lift the unit.
TILTING OF TRAILER can result in
personal injury or equipment damage.
Install unit properly on trailer (if applicable)
according to trailer manual.
rwarn1.1 3/93
rsb20.2 5/94 Ref. ST-800 652 / ST-800 477 / ST-134 686-C
1 Lifting Eye
2 Lifting Forks
Use lifting eye or lifting forks to
move unit.
3 Cross Member Support
If using lifting forks, lift only from end
with cross member support (engine
end).
4 Trailer
Install unit on trailer according to
trailer manual.
Location And Airflow
OR
OR
1
Movement
2
3
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
4
Figure 3-1. Movement And Location Of Welding Generator
OM-481 Page 5
Overall dimensions (A, B, and C) include lifting eye, handles, hardware, etc.
NOTE
ST-156 466
B
A
C
Inches Millimeters
A 58 1473
B 32 813
C 68 1727
D 68 1727
E 62-3/8 1584
F 50-1/2 1283
G 46-1/2 1181
H 36 914
J 28-3/16 716
K 13-3/4 349
L 9-3/4 248
M 6-1/8 156
N 29-7/8 759
P 32 813
Q 1-1/16 27
R 21/32 Dia. 16.7 Dia.
16 Holes 16 Holes
D
E
F
G
H
J
K
L
M
N
P
Q
R
Engine End
Figure 3-2. Overall Dimensions And Base Mounting Hole Layout
S-0024-C
Do not exceed operating angles while
running or engine damage will occur.
Engine
End
20°
20°
15°
17.5°
Figure 3-3. Maximum Welding Generator Operating Angles
OM-481 Page 6
3-2. Installing Exhaust Pipe And Rain Cap
rsb19.4* 5/92 ST-154 087
Stop engine and allow to cool.
1 Exhaust Pipe
2 Muffler Pipe
Install exhaust pipe over muffler
pipe. Secure exhaust pipe to top
cover using supplied hardware.
3 Rain Cap
Install so cap opens toward front of
unit.
1/2 in
Tools Needed:
1
2
3
Do not blow exhaust toward
air cleaner or air intake.
Figure 3-4. Installing Exhaust Pipe And Rain Cap
3-3. Connecting The Battery
WARNING
SPARKS can cause BATTERY GASES TO EXPLODE; BATTERY ACID can burn eyes and skin.
Stop engine before disconnecting or connecting battery cables.
Always wear a face shield and proper protective clothing when working on a battery.
Do not allow tools to cause sparks when working on a battery.
rwarn2.1 9/91
ST-153 654-A / Ref. ST-131 784-A / Ref. S-0756
1 Engine Control Switch
Place switch in the Off position.
Remove rear left side panel.
2 Positive (+) Battery Terminal
3 Positive (+) Battery Cable
Connect positive cable first.
4 Negative () Battery Terminal
5 Negative () Battery Cable
Connect negative cable last.
Reinstall side panel.
If engine does not crank, check bat-
tery voltage according to Section
6-6.
Tools Needed:
1/2 in
1
4
2
+
3
5
Figure 3-5. Connecting The Battery
OM-481 Page 7
3-4. Lower Front Panel
Ref. ST-134 687-B
Open lower front door.
1 Equipment Grounding
Terminal (Section 3-5)
2 Remote 14 Receptacle
(Section 3-9)
3 Positive (+) Weld Output
Terminals (Section 3-8)
4 Negative () Weld Output Ter-
minals
Close door.
Tools Needed:
3/8, 1/2 in
1
2
34
Route all cables under bar.
Figure 3-6. Lower Front Panel
3-5. Generator Auxiliary Power System
A. Selecting Equipment
WARNING
ELECTRIC SHOCK can kill.
Use only grounded or double insulated equipment.
1 Auxiliary Power Receptacles
Neutral Bonded To Frame
2 3-Prong Plug From Case
Grounded Equipment
3 2-Prong Plug From Double
Insulated Equipment
OR
2
3
1
Ref. ST-134 687-B / ST-800 577
Be sure equipment has this
symbol and/or wording.
Figure 3-7. Proper Equipment To Use
OM-481 Page 8
B. Grounding The Generator To A Truck Or Trailer Frame
rsb5.1 9/93 S-0854
1 Generator Base
2 Metal Vehicle Frame
3 Equipment Grounding
Terminal
4 Grounding Cable
OR
1
2
Electrically bond generator
frame to vehicle frame by
metal-to-metal contact.
GND/PE
Use #10 AWG or
larger insulated
copper wire.
2
3 4
Figure 3-8. Grounding Methods
C. Grounding The Generator When Connecting To Home, Shop, Or Farm Wiring
rsb5.1 8/93 ST-800 576
1 Equipment Grounding
Terminal
2 Grounding Cable
Use #10 AWG or larger insulated
copper wire.
3 Water Meter
4 Metal Water Pipe
5 Driven Ground Rod
Ground generator to system earth
ground if supplying power to a
premises (home, shop, farm) wiring
system see Section 9.
2
4 or 5
OR
GND/PE
1 2
4
Use metal water pipe or driven ground rod or
other means as stated in electrical codes.
5
3
Figure 3-9. Grounding When Supplying Building Systems
OM-481 Page 9
3-6. Engine Prestart Checks
WARNING
ENGINE FUEL can cause fire or
explosion.
Stop engine before fueling.
Do not fuel while smoking or near sparks or flames.
Do not overfill tank; clean up any spilled fuel.
USE OF GASOLINE will damage engine.
Do not use gasoline.
Lack of lubrication in gasoline damages injector pump
and injectors.
REMOVE FUEL CAP SLOWLY; FUEL
SPRAY may cause injury; FUEL may be
under pressure.
Rotate fuel cap slowly and wait until hissing stops
before removing cap.
rwarn3.1* 3/93
rsb4.2 11/92 ST-156 467-B
Check all fluids daily. Engine must
be cold and on a level surface.
Add fresh fuel before starting
engine the first time (see
Figure 6-2).
1 Fuel Cap
Do not run out of fuel or air enters
fuel system and causes starting
problems.
2 Oil Dipstick
3 Oil Fill Tube
If oil is not up to full mark, add oil
(see Figure 6-2).
Engine stops if oil pressure is too
low or oil temperature is too high
(see Figure 4-9).
4 Exhaust Pipe
Follow break-in procedure in
engine manual.
If unburned fuel and oil collect in
exhaust pipe during break-in, see
Section 8.
Close door
1
FUEL
OIL
2
3
Full
1/2 in
(13 mm)
Full
4
Figure 3-10. Checking Oil And Fuel
OM-481 Page 10
3-7. Selecting And Preparing Weld Output Cables
sb6.5* 5/94 S-0752
1 Weld Output Cable
Determine total cable length in weld
circuit and maximum welding am-
peres. Use Table 3-1 to select prop-
er cable size.
Use shortest cables possible.
Do not use damaged cables.
2 Terminal Lug
Use lugs of proper amperage
capacity and hole size for connect-
ing to work clamp, wire feeder or
electrode holder, and weld output
terminals.
3 Wire Feeder
4 Insulated Electrode Holder
Install according to manufacturer’s
instructions.
5 Work Clamp
Install onto work cable.
10 ft (3 m)
1
Total Cable
Length In Weld
Circuit = 20 ft (6 m)
10 ft (3 m)
For Example,
2
5
2
Tools Needed:
3 4
OR
Figure 3-11. Selecting And Preparing Weld Output Cables
Table 3-1. Weld Cable Size*
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10 To 60%
Duty Cycle
60 Thru 100%
Duty Cycle
10 Thru 100% Duty Cycle
100 4 4 4 3 2 1 1/0 1/0
150 3 3 2 1 1/0 2/0 3/0 3/0
200 3 2 1 1/0 2/0 3/0 4/0 4/0
250 2 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0
300 1 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0
350 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 2-4/0
400 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 2-4/0
500 2/0 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-3/0
600 3/0 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 3-4/0
700 4/0 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 3-4/0 4-4/0
800 4/0 2-2/0 2-3/0 2-4/0 3-4/0 3-4/0 4-4/0 4-4/0
900 2-2/0 2-3/0 2-4/0 3-3/0 3-4/0 4-4/0 4-4/0
1000 2-2/0 2-3/0 2-4/0 3-3/0 4-3/0 4-4/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. S-0007-D
OM-481 Page 11
3-8. Connecting To Weld Output Terminals
WARNING
ELECTRIC SHOCK can kill.
Always wear dry insulating gloves.
Do not touch live electrical parts.
Stop engine before making any weld output connections.
Read Safety Precautions at beginning of this manual.
rwarn13.1 2/92
Ref. ST-134 687-B / ST-145 043
1 Positive (+) Weld Output
Terminals
2 Negative () Weld Output Ter-
minals
For Direct Current Electrode Posi-
tive (DCEP), connect work cable to
terminal and electrode holder
cable to + terminal.
For Direct Current Electrode Nega-
tive (DCEN), reverse cable con-
nections.
To prevent overheating and dam-
age, two terminals are provided for
each polarity in case more than one
cable is needed to carry current to
a single arc (see Table 3-1). This
unit is not designed to supply multi-
ple arcs.
Tools Needed:
3/8, 7/8 in
12
Figure 3-12. Weld Output Connections
3-9. Remote 14 Receptacle Or Terminal Strip Information And Connections
A. Remote 14 Receptacle
sb7.1 5/94 ST-800 907 / Ref. S-0004-A / S-0750 / Ref. ST-141 127-B
1 Remote 14 Receptacle RC3
(See Table 3-2)
2 Keyway
3 Plug
4 Threaded Collar
To connect to receptacle, align
keyway, insert plug, and tighten
threaded collar.
3
4
OR
AJ
B
K
I
C
L
NH
D
M
G
E
F
12
Tools Needed:
3/8 in
Figure 3-13. Remote 14 Connections
OM-481 Page 12
Table 3-2. Remote 14 Socket Information
A 24 volts ac. Protected by circuit breaker CB4.
B Contact closure to A completes 24 volts ac contactor control circuit.
I 115 volts ac. Protected by circuit breaker CB3.
J Contact closure to I completes 115 volts ac contactor control circuit.
G Circuit common for 24 and 115 volts ac circuits.
C +10 volts dc output to remote control.
D Remote control circuit common.
E 0 to +10 volts dc input command signal from remote control.
K Chassis common.
Socket Information
*The remaining sockets are not used.
Socket*
B. Terminal Strip 3T
WARNING
ELECTRIC SHOCK can kill; UNEXPECTED OUTPUT can cause serious injury.
Do not touch live electrical parts.
Stop engine before making any internal inspection or connections.
Do not connect to Remote 14 receptacle and terminal strip at the same time.
Output (Contactor) can be energized from either the receptacle or terminal strip. Use only one remote control method.
ST-134 839-A
Stop engine.
Remove plug from remote control
cord.
Open right side door.
1 Strain Relief
Route cord leads through strain
relief.
2 Terminal Strip 3T
3 Label
Connect leads to 3T using terminal
information shown in Table 3-2.
Secure cord in strain relief.
Close door.
15A
0-10VDC
0-1 k
Circuit Common
Equipment
S-138 042
24VAC
A
B
C
D
E
G
I
K
J
Contactor
Output
Ground
Feeder
115VAC
Contactor
24VAC 10A Feeder Power
3T
Power
115VAC
Remote
A/V
Ω
2
Tools Needed:
1
3
Figure 3-14. Terminal Strip 3T Connections
OM-481 Page 13
3-10. Installing Optional Ether Cylinder
WARNING
IMPROPER HANDLING OR EXPOSURE TO ETHER
can seriously harm your health.
Follow manufacturer’s safety instructions on cylinder.
INJECTING ETHER WHILE ENGINE IS RUNNING
can damage engine.
Do not use Ether Starting Aid while engine is running.
After installing cylinder, wait at least 10 minutes before use to let ether
particles settle to prevent atomizer plugging.
rsb15.1 6/92A ST-153 382
Stop engine. Open side door(s) to
locate ether starting aid.
1 Ether Cylinder
Obtain cylinder.
2 Nozzle
Remove protective cover, and
clean nozzle and fitting area on
cylinder.
3 Clamp
4 Fitting
5 Cap
6 Valve
Remove valve cap, and clean fitting
area.
Insert cylinder through clamp and
onto fitting.
Tighten clamp when cylinder is tight
in fitting.
Put cap on fitting when cylinder is
removed.
1
2
3
4
6
5
Tools Needed:
Figure 3-15. Installing Ether Cylinder
OM-481 Page 14
SECTION 4 OPERATING THE WELDING GENERATOR
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Always wear dry insulating gloves.
Insulate yourself from work and ground.
Stop engine before installing or servicing.
Keep all panels and covers securely in place.
WELDING can cause fire or explosion.
Do not weld near flammable material.
Watch for fire; keep extinguisher nearby.
Do not locate unit over combustible surfaces.
Do not weld on closed containers.
Allow work and equipment to cool before handling.
ARC RAYS can burn eyes and skin;
NOISE can damage hearing.
Wear welding helmet with correct shade of filter.
Wear correct eye, ear, and body protection.
FUMES AND GASES can be hazardous.
Keep your head out of the fumes.
Ventilate area, or use breathing device.
Read Material Safety Data Sheets (MSDSs) and
manufacturers instructions for material used.
ENGINE EXHAUST GASES can kill.
Do not breathe exhaust fumes.
Use in open, well-ventilated areas, or vent exhaust
outside and away from any building air intakes.
ENGINE FUEL can cause fire or explo-
sion.
Stop engine before fueling.
Do not fuel while smoking or near sparks or flames.
Do not overfill tank; clean up any spilled fuel.
MOVING PARTS can cause injury.
Keep away from moving parts such as fans, belts,
and rotors.
Keep all doors, panels, covers, and guards closed
and securely in place.
MAGNETIC FIELDS FROM HIGH CUR-
RENTS can affect pacemaker operation.
Pacemaker wearers keep away.
Wearers should consult their doctor before going
near any welding operations.
See Safety Precautions at beginning of manual for ba-
sic welding safety information.
WARNING
rwarn5.1 10/91
Ref. ST-134 687-B
1 DC Voltmeter
2 DC Ammeter
3 Amperage And Voltage Ad-
justment Control
4 Ether Starting Aid Switch (Op-
tional)
5 Service Engine Air Cleaner
Light (Section 6-2)
6 Amperage/Voltage Control
Switch
7 CC/CV Switch
8 Output (Contactor) Switch
9 Check Cooling System/Alter-
nator Light (Section 6-2)
10 Engine Control Switch
11 Engine Hour Meter
12 Fuel Gauge
13 Battery Ammeter
14 Oil Pressure Gauge/Switch
15 Oil Temperature Gauge/
Switch
16 Ampere Ranges Switch
12 3 45678
9
10
11
12
16 15 14 13
Figure 4-1. Controls
Wear the following while welding:
1 Dry, Insulating Gloves
2 Safety Glasses With Side
Shields
3 Welding Helmet With Correct
Shade Of Filter (See ANSI
Z49.1)
sb3.1 1/94
123
Figure 4-2. Safety Equipment
OM-481 Page 15
1 Work Clamp
Connect work clamp to a clean,
paint-free location on workpiece, as
close to weld area as possible.
Use wire brush or sandpaper to
clean metal at weld joint area. Use
chipping hammer to remove slag
after welding.
sb4.1 2/93
Tools Needed:
1
Figure 4-3. Work Clamp
Ref. ST-131 784-A
1 CC/CV Switch
Use switch to select type of weld
output.
Use constant current (CC) position
for SMAW and CAC-A.
Use constant voltage (CV) position
for wire feeding processes, GMAW,
SAW, and FCAW. When using CV
position, place Ampere Ranges
switch in CV position (see
Figure 4-5).
1
Figure 4-4. CC/CV Switch
CAUTION
ARCING can damage switch.
Do not change Ampere Ranges switch position while welding.
Arcing inside switch can damage contacts, causing switch to fail.
rwarn6.1 2/93
1 Ampere Ranges Switch
Use switch to select weld output
range.
2 Amperage And Voltage Ad-
justment Control
Use control to adjust amperage
within range selected by Ampere
Ranges switch.
The numbers are a percentage of
the range selected and not an ac-
tual value.
Control may be adjusted while
welding.
1
2
Example Of Front Panel Amperage Control
Set Range Set Percentage Weld Output = 90 A DC
In Example:
Range = 55 to 125 A DC
Percentage Of Range = 50%
Weld Output = 90 A DC (50% of 55 to 125)
Figure 4-5. Amperage Controls
OM-481 Page 16
WARNING
ELECTRIC SHOCK can kill.
Do not touch live electrical parts.
Do not touch weld output terminals when engine is running.
Do not touch electrode and work clamp at the same time.
rwarn7.1 9/91
1 Output (Contactor) Switch
Use switch to select way of control-
ling unit output.
For front panel control, place switch
in On position.
For remote control, place switch in
Remote position (see Section 3-9).
Weld output terminals are energized
when Output (Contactor) switch is On
and engine is running.
1
Figure 4-6. Remote Controls
1 Amperage/Voltage Control
Switch
Use switch to select way of control-
ling amperage and voltage
adjustment.
For front panel control, place switch
in Panel position.
For remote control, place switch in
Remote position.
2 Remote Foot Control
3 Remote Amperage Control
See example below.
1
Example Of Combination Remote Amperage Control
Set Switches
Adjust Remote Control
Set Percentage
Min = 55 A DC/CC
Percentage Of Range = 50%
Max = 90 A DC/CC (50% of 55 to 125)
In Example:
S-0774 / S-0769
Set Range
Min (55 A DC/CC)
Max (90 A DC/CC)
2
3
Figure 4-7. Amperage/Voltage Control Switch
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Miller Big Blue 600D Owner's manual

Category
Engine
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI