FMI GA6080 Operating instructions

Type
Operating instructions
INSTALLING DAMPER CLAMP ACCESSORY (GA6080)
FOR VENTED OPERATION
You may use this heater as a vented product. There are three reasons for operating your heater in the
vented mode.
1. Thereplacedoesnotmeettheclearancetocombustiblesrequirementsforvent-freeoperation.
2. Stateorlocalcodesdonotpermitvent-freeoperation.
3. You prefer vented operation.
Ifreasonsnumber1or2aboveapplytoyou,youmustpermanentlyopenchimneyuedamper.The
damperclampwillkeepdamperopenandinsureventedoperation.
Seechartbelowforminimumpermanentueopeningyoumustprovide.Attachdamperclampsothe
minimumpermanentueopeningwillbemaintainedatalltimes.
Area of Various Standard Round Flues
Diameter Area
5" 20sq.inches
6" 29sq.inches
7" 39sq.inches
8" 51sq.inches
Chimney
Height
Minimum Permanent
Flue Opening
6' to 15' 39sq.inches
15' to 30' 29sq.inches
Damper
Damper
Clamp
Damper
Clamp
Damper
Damper
Manufactured FireplaceMasonry Fireplace
Attaching Damper Clamp
101717-01
Rev. B
02/07
101717 01
NOTAUPC
2701IndustrialDrive
P.O.Box90004
BowlingGreen,KY42102-9004
www.desatech.com
1-866-672-6040