FMI GA6080 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the FMI GA6080 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLING DAMPER CLAMP ACCESSORY (GA6080)
FOR VENTED OPERATION
You may use this heater as a vented product. There are three reasons for operating your heater in the
vented mode.
1. Thereplacedoesnotmeettheclearancetocombustiblesrequirementsforvent-freeoperation.
2. Stateorlocalcodesdonotpermitvent-freeoperation.
3. You prefer vented operation.
Ifreasonsnumber1or2aboveapplytoyou,youmustpermanentlyopenchimneyuedamper.The
damperclampwillkeepdamperopenandinsureventedoperation.
Seechartbelowforminimumpermanentueopeningyoumustprovide.Attachdamperclampsothe
minimumpermanentueopeningwillbemaintainedatalltimes.
Area of Various Standard Round Flues
Diameter Area
5" 20sq.inches
6" 29sq.inches
7" 39sq.inches
8" 51sq.inches
Chimney
Height
Minimum Permanent
Flue Opening
6' to 15' 39sq.inches
15' to 30' 29sq.inches
Damper
Damper
Clamp
Damper
Clamp
Damper
Damper
Manufactured FireplaceMasonry Fireplace
Attaching Damper Clamp
101717-01
Rev. B
02/07
101717 01
NOTAUPC