Alula RE207T is an Outdoor Door/Window Sensor that can help protect your home or business by detecting the opening and closing of doors, windows, or other objects, triggering an alarm when the magnet is pulled away from the sensor or when an external contact is opened. It has an industry-leading wireless range and battery life, a wide magnetic gap distance, and two built-in external contact zones. The sensor is also IP67-rated, making it weatherproof and ideal for outdoor use.

Alula RE207T is an Outdoor Door/Window Sensor that can help protect your home or business by detecting the opening and closing of doors, windows, or other objects, triggering an alarm when the magnet is pulled away from the sensor or when an external contact is opened. It has an industry-leading wireless range and battery life, a wide magnetic gap distance, and two built-in external contact zones. The sensor is also IP67-rated, making it weatherproof and ideal for outdoor use.

Outdoor Door/Window Sensor is a full-featured security
transmitter with industry-leading wireless range and battery
life. It is designed to sense the opening and closing of
gates, sheds, and other outdoor open/close applications.
An alarm signal will be transmitted when the magnet is
pulled away from the sensor, or when an external contact is
opened.
Features
Industry-leading wireless range and battery life
Wide magnetic gap distance
Two built-in external contact zones
Secure encrypted wireless transmissions
IP67 waterproof enclosure rating
5-year warranty
Enroll all variants by entering their serial numbers into the
security panel. Alternatively, the sensor can be enrolled in
one of the following ways:
DSC®, Qolsys® and Interlogix® variants are enrolled by
placing the panel into enrollment mode, and then pulling
the battery tab or tampering the device.
Honeywell® and 2GIG® variants are enrolled by placing
the panel into wireless enrollment mode and either
removing the battery tab while holding the tamper, or by
tripping the device three times. These sensors must be
enrolled as a “Loop 2” sensor.
Install by rst attaching the mounting plate and magnet to a
door, window, or fence using screws (provided) or cable ties
(not provided).
Use the panel installation guide to verify proper system setup.
Outdoor Door/Window Sensor
I
N
S
T
A
L
L
G
U
I
D
E
I
Mounting Tips
Face of mounting plate marked “Flat Mount” is to be
mounted against at surfaces (e.g. square wood post).
Face of mounting plate marked “Pole Mount” is to be
mounted against round surfaces (e.g. fence post).
Resolution Compatibles
Alignment Marks
Cover-Securing Screw Hole
Mounting Screw Holes
Magnet
Enrollment of External Contacts
Interlogix External 1 replaces reed switch if installed.
Interlogix External 2 is enrolled by powering up the
sensor while holding the tamper.
Honeywell & 2GIG External 1 & 2 should be enrolled
as Loop 1 and Loop 3, respectively. Enroll each
external by tripping it 3 times.
DSC Externals are enrolled by tripping the desired
external while the device is tampered.
External Contacts can be installed by routing the wires through
the back of the enclosure. A thinned area in the enclosure must be
punched out with a screwdriver to allow the wires through. After
routing and connecting the wires, reseal the hole with silicone
caulk.
Do not use end-of-line resistors.
Wire contacts to one or both outside terminals using the
center terminal as a shared common.
The sensor defaults to use normally closed contacts (alarm
condition when contact is open).
To reprogram external inputs, set both externals to the
desired non-alarm state and restart (remove and reinstall
battery) the device 3 times while holding the tamper
switch.
Thinned area for external
contact wires
Metal installs should include pre-drilling holes before using
screws to secure the mounting plate and magnet.
Wireless performance is optimized when mounted near the top
of the gate or door in a vertical orientation.
Removal Tamper is implemented by screwing the provided screw
with rubber washer through the removal tamper screw hole in the
base and into the mounting surface. Remove the battery for access
to the removal tamper screw hole.
Removal tamper
screw hole
Pro Tips
Make sure to align the alignment marks on the sensor and magnet
when mounting. Finish by latching the sensor to the mounting
plate and tightening the cover-securing screw to secure the sensor
in place.
Magnet Gap Specications
Non-Ferromagnetic Surface (e.g. Wood, Vinyl, etc.)
Nominal Mounting Distance
X Axis - Make
Break
Y Axis - Make
Break
Z Axis - Make
Break
2.70 inches (6.86 cm)
2.80 inches (7.11 cm)
2.85 inches (7.24 cm)
3.50 inches (8.89 cm)
3.55 inches (9.02 cm)
3.27 inches (8.31 cm)
3.33 inches (8.46 cm)
Ferromagnetic Surface (e.g. Iron, Nickel, etc.)
Nominal Mounting Distance
X Axis - Make
Break
Y Axis - Make
Break
Z Axis - Make
Break
1.90 inches (4.83 cm)
2.00 inches (5.08 cm)
2.05 inches (5.21 cm)
2.50 inches (6.35 cm)
3.00 inches (7.62 cm)
2.32 inches (5.89 cm)
2.37 inches (6.02 cm)
*Sensitivity can be adjusted by moving the magnet in the
closed position farther away from the sensor.
Z Axis
Y Axis
X Axis
X Axis
WARRANTY
Alula will replace non-portable products that are defective in their
rst ve (5) years and all portable products in their rst two (2)
years.
IC NOTICE
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et
(2) L’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
IC: 8310A-RE107, 8310A-RE207, 8310A-RE307
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved by Alula could
void the user’s authority to operate this equipment.
FCC ID: U5X-RE107, U5X-RE207, U5X-RE307
TRADEMARKS
Alula is a trademark owned by Alula Holdings, LLC.
Interlogix, Honeywell, DSC, Qolsys, and 2GIG are registered
trademarks owned by United Technologies Electronic Controls Inc.,
Honeywell International Inc., Tyco Safety Products Canada Ltd,
Qolsys Inc. and 2GIG, respectively. Alula products will function with
one of either Interlogix (formerly GE), Qolsys, Honeywell, DSC, or
2GIG systems. However, no Alula product is produced by, endorsed
by, nor is ofcially associated with Interlogix (formerly GE), Qolsys,
Honeywell, DSC or 2GIG. Alula recommends verifying proper
enrollment and operation, per control panel installation instructions
at installation.
Panasonic is a registered trademark owned by Panasonic
Corporation.
Specications subject to change without notice
Physical
Housing Dimensions
Weight with Battery
Mounting Fasteners
Removal Tamper Fastener
3.3 x 1.3 x 2.8 inches (8.4 x 3.3 x 7.1 cm)
5.7 ounces (161.6 grams)
Four 1 inch stainless steel screws (provided)
One 11/4 inch stainless steel screw with rubber washer (provided)
Environmental
Operating Temperature
Maximum Humidity
Ingress Protection Rating
-40° to 158°F ( -40° to 70°C)
100% Relative Humidity (RH)
IP67
Sensor Specications
Frequency
Replacement Battery
Nominal Battery Life
Battery Voltage
Current Draw
Transmitted Indications
Max Wire Length on External
Contacts
433.92MHz, 319.5MHz, 345MHz
One Panasonic® CR123A Lithium Battery
10 years
3.0 VDC (Nominal), 2.2 VDC (Low)
20 mA (Maximum), 0.6 uA (Quiescent)
Cover Tamper, Removal Tamper, Low Battery, Supervision
7.5 feet
Certication
RE107, RE207, RE207T, RE307 FCC, IC
Specications
47-0060-01 • REV B • 2019-01-25
Tech Support Line • (888) 88-ALULA • (888) 882-5852
alula.net
01
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Alula RE207 Owner's manual

Type
Owner's manual
This manual is also suitable for

Alula RE207T is an Outdoor Door/Window Sensor that can help protect your home or business by detecting the opening and closing of doors, windows, or other objects, triggering an alarm when the magnet is pulled away from the sensor or when an external contact is opened. It has an industry-leading wireless range and battery life, a wide magnetic gap distance, and two built-in external contact zones. The sensor is also IP67-rated, making it weatherproof and ideal for outdoor use.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI