Neutrik CONN1240B, CONN1241, CONN1241B, CONN1242, CONN1242B User guide

  • Hello! I've reviewed the assembly instructions for the Neutrik NL2FXX-W-* and NL4FXX-W-* Loudspeaker Cable Connectors. This document provides details on how to safely assemble these connectors, including safety precautions, cable preparation and the assembly process itself. Feel free to ask me any questions you have about the document or the connectors.
  • Can speakON connectors be used as AC mains power connectors?
    Can connector be engaged under load?
    What wire sizes are compatible with these connectors?
    What is the rated voltage and current for these connectors?
ASSEMBLY INSTRUCTION
R
Page 1BDA 638
ð
ATTENTION: speak IS NOT TO BE USED AS AN AC MAINS OR POWER SUPPLY CONNECTOR!ON®
C CONNECTOR NOT TO BE ENGAGED AND DISENGAGED IN NORMAL USED WHEN LIVEAUTION:
OR UNDER LOAD.
ATTENTION: NE PAS UTILISER POUR COUPER LE COURANT
PRODUCT IS INTENDED FOR FACTORY ASSEMBLY ONLY
A
B
C
A
B
Place bushing and chuck overthe (1) (2) the
cable.
Important: huckC and Bushing cannot be placed
over the cable after the assembly or the insert.
Prepare cable as shown.the
Slide the cable into the contacts and clamp
BASSEMBLY INFORMATION
CABLE PREPARATION: 2 POLE
Approval based:
Rating:
Wire size:
Cable O.D.: *-S:
*-L:
EN/IEC
EN 61984
IEC 61984
250 V ac / 30 A
1.0 - 4.0 mm2
6.0 - 12.0 mm (0.24 - 0.47")
10.0 - 16.0 mm (0.39 - 0.63")
UL/CSA
UL 1977
CAN/ No.CSA C22.2 182.3
250 V ac / 30 A
16 - 11 AWG
6.0 - 12.0 mm (0.24 - 0.47")
10.0 - 16.0 mm (0.39 - 0.63")
CABLE PREPARATION: 4 POLE
C
WIRING: 2 POLE WIRING: 4 POLE
1+
1-
2-
2+
1+
1-
[0. "]35
9mm
[”]1.06
2mm7
[0. "]35
9mm
[”]1.06
2mm7
1.
2.
speakON®Loudspeaker Cable Connector
|
NL2FXX-W-* & NL4FXX-W-*
AIMPORTANT SAFETY INFORMATION
Torx size
T8
Torque Value 0.7 Nm
(6.2 inch pound)
ASSEMBLY INSTRUCTION - speakON Cable Connector NL2FXX-W-* & NL4FXX-W-*
I
Page 2BDA 638
E
Position chuck (1) on insert (2).
Slide intoinsert (2) with chuck (1) together
housing (3)
.
Important: Align the chuck by positioning the
nose into keyway.
Slide bushing (4) over ( ).chuck 1
Hold the connector with the NEUTRIK tool (5)
and tighten bushing with the NEUTRIK tool
(6) as shown.
For an exact mounting position use a torque
wrench with mm ( inch) and27 1 1/8 hex bit (7)
tighten it with 2. Nm ( ).5 22 inch pound / 1.8 lb-ft
NEUTRIK tool Information:
(5) HTLACA
(6) HTLACB
ð
D
Important:
Push and turn
simultaneously.
3
1.
2.
D
E
4
5
7
Neutrik
HTLACA
27 mm 1 1/8 inch
Hex bit
4
6
Torque Value 2.5 Nm
(22 inch pound / 1.8 lb-ft)
Neutrik
HTLACB
8
FOR DISASSEMBLY!
1. Use the Neutrik tool HTLACB.
Position the tool on the surfaces and open the2.
clamping sleeve.
HTLACB
CAUTION
To ensure protection category, do not expose the connection to
bending forces (e.g. do not attach loads to the cable, no free-
dangling cable windings etc.).
LIECHTENSTEIN
ASSEMBLY INSTRUCTION - speakON Cable Connector NL2FXX-W-* & NL4FXX-W-*
I
https://www.neutrik.com/products/audio/speakon
FMore Information on the www.neutrik.com
Page 3
Draft. Nr.: BDA 638 Update:V2 2022-08-11
II
www.neutrik.com
Neutrik AG LI T: +423 / 237 24 24 F: +423 232 53 93/
Neutrik USA Inc. USA T: +1 704 / 972 3050 F: +1 704 438 9202/
Neutrik ()
UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 811 439/
Neutrik Vertriebs GmbH DE/NL/AT/DK T: +49 8131 / 280 890 F: +49 8131 280 830/
Neutrik France FR T: +33 1 4131 6750 F: +33 1 4131 0511//
Neutrik Tokyo Ltd. JP T: +81 3 3663 4733 F: +81 3 3663 4796//
Neutrik Hong Kong Ltd. HK T: +852 2687 6055 F: +852 2687 6052//
R
Data subject to change without prior notice. 20 NEUTRIK ALL RIGHTS RESERVED22 . NEUTRIK are registered trademark of Neutrik AG. .©®®
DDISASSEMBLY INFORMATION
ESAFETY INFORMATION
CFINISHED CONNECTOR
NL2FXX-W-* NL4FXX-W-*
SAFETYWARNING
For safety and certification reasons the connector must be
replaced in case of any broken parts or .excessive wear and tear
FORCE
/