Edision 714509 NEVOSWITCH AMPLIFIER 5x5, 714901 NEVOSWITCH TAP 5x5x5 12dB, 714902 NEVOSWITCH TAP 5x5x5 15dB, 714903 NEVOSWITCH TAP 5x5x5 20dB, 714904 NEVOSWITCH TAP 5x5x5 25dB User manual

  • Hello! I've reviewed the data sheet for the Televes Multiswitches, including models like MS54C, MS56C, MS58C, and others. This document details features like multiple input and output options, various powering methods, and an ECO system for reduced power usage. I'm ready to help answer your questions about these devices and their capabilities.
  • What are the powering options for this range of switches?
    What is the ECO system in this range of products?
    Can I power pre-amplifiers, BOSS antennas, or LNBs through the switch?
    What should I do to see the terrestrial signal if no user is powering the system?
www.televes.com
Hoja Técnica
Data Sheet
EN
ES
NEVOswitch 5x
NEVOswitch 5x 2
SAT para hacerlo compatible con LNB QUAD.
En el caso de la entrada/salida Ter se puede seleccionar
el sentido de paso de la corriente mediante el switch 1.
Esta gama incorporá el sistema ECO por el cual el consu-
mo de la instalación se reduce a medida que disminuye
el número de usuarios conectados. Incluso el consumo
es 0 A, si no se utiliza alimentación local y no hay ningún
usuario conectado. En este caso para poder ver la señal
Terrestre sería necesario que al menos un usuario estu-
viera alimentando la instalación.
Para un funcionamiento correcto de la instalación es ne-
cesario cargar el paso de las señales con 75 ohmios, para
ello se debe con gurar el switch 2 en la posición en el
último modulo de la cascada.
Permite regular el nivel de salida de cada usuario de ma-
nera individual (opción no disponible en la gama QUAD).
ES
Nueva gama de conmutadores de 5 entradas y múltiples
salidas de usuario, (4…32 según ref. ). Dispone de otras
5 salidas de paso que permiten encadenar varios elemen-
tos ampliando el número de usuarios  nales de la insta-
lación (cascada).
Dispone de las siguientes opciones de alimentación:
- A través del jack de Power DC (12V)
- A través de la línea V-Low (12VDC)
- A través de la entrada o salida de la señal TERR.
- Aplicando entre 12 y 18V en los conectores de salida de
usuario.
El paso de alimentación 12 Vdc es hacia las entradas/sa-
lidas Ter, V-Low, para la alimentación de preampli cado-
res, antenas BOSS, LNB ú otros elementos encadenados
(cascada).
En las referencias QUAD, el multiswitch genera las dife-
rentes combinaciones de tensión y tono hacia la entradas
MSW 5x QUADMSW 5x
EN
New range of input/multiple output switches, (from 4 to 32,
according to reference). It can be used as a cascade element
since it has 5 outputs to connect to other switches and in-
crease the number of users.
It has the following powering options:
- Through the Power DC Jack (12 Vdc)
- Through the V-Low input (12 Vdc).
- Through the TERR input or output.
- Applying 12 /18V at any user output.
12V DC passes through the Terr and V-LOW input/output
to power pre-ampli ers, BOSS antennas, LNB or other ele-
ments (cascade).
The switch can generate the required voltage or voltage +
tone (QUAD references) so its compatible with any QUAD
LNB.
The user can select the direction of the current/voltage
through the TERR input/output using the Switch No. 1.
This range of products has been designed with the ECO sys-
tem: as the number of users decreases, the power consump-
tion of the system will decrease as well. When no users are
connected and there’s no local mains, the consumption will
go down to 0A. In this case scenario, to see the DTT signal at
least one user must be connected to the system to power it.
Any signal must balanced to 75 ohms (Switch No. 2) in the
last element of the chain for the proper operation of the
system.
This range allow to control the output signal level of every
user individually. (Not available for the QUAD range).
3
ES
Estos dispositivos complementan la gama anterior de
MSW de forma que se consigue ampliar la instalación a
un mayor número de usuarios optimizando la señal que
le llegaría a cada uno.
En los ampli cadores mediante el switch , podemos ac-
tivar/desactivar el paso de corriente para la alimentación
de preampli cadores, antenas BOSS,…
EN
This range of products has been designed as a complement
to the former MSW range, so any facility can be easily exten-
ded to more users, optimizing every output signal.
The voltage/current can be activated/deactivated in the
MSW ampli ers to power pre-ampli ers, BOSS antennas, etc.
.
MSW 5x Splitter MSW 5x Tap MSW 5x Ampli er
T
Nota / Note:
Switch 1
Switch 2
NEVOswitch 5x 4
Especif.
técnicas
Technical
speci cations
714501
MS54C
714502
MS56C
714503
MS58C
714504
MS512C
714505
MS516C
Tipo
Type
5x5x4 5x5x6 5x5x8 5x5x12 5x5x16
Margen frec.
Frequency range MHz SAT 950-2400
TER 47-862
Nivel de salida
Max output level dBμV SAT
EN50083-3 IM35dBc
109
TER
DIN 45004-B
105
Ganancia máxima
Max
gain
dB
SAT
-
TER
-
Ecualizador Equaliser
SAT
-
TER
-
Pérdidas de paso Through losses
SAT
- 4 ± 2 - 5 ± 5 - 8 ± 2
TER - 3 ± 1 - 5 ± 2
Pérdidas deriv. Tap losses
(adjustable -12dB)
SAT
Max - 5 ± 5 * - 5 ± 5 *
Min
- 8 ± 5 * - 10 ± 5 *
TER Max
- 3 ± 5
* - 3 ± 5 *
Aislamiento
IN-OUT
Isolation
IN-OUT
SAT
>30
Paso
corriente
LNB control signals
mA LNB/TER
/ Input max. 250
A
Total
1
Alimentación
Powering
Vdc 12
Paso DC
DC pass
In-Out / Out-In **
Consumo máx.
Max. consumption
mA Power Supply 12Vdc (PWR)
65 ± 5 105 ± 10 130 ± 10
Receiver (12/18V)
33 ***
Rango de temperatura
Temperatura Range
ºC –5….+45 ºC
Indice de protección
Protection level
IP
IP20
Peso
Weight
g 365 400 765 800
Dimensiones
Dimensions
mm
140x120x30
140x255x30
(***) 33 x nº users + PWR if PSU is not used
(*) Ajustable -12dB / Adjustable -12dB (**) Bidireccional / Bidirectional
5
714506
MS524C
714507
MS532C
714402
MS56NCQ
714403
MS58NCQ
714404
MS512NCQ
714405
MS516NCQ
714901
AZ512G
714902
AZ515G
714903
AZ520G
714904
AZ525G
714905
SAV525G
714509
MS530VGQ
5x5x24 5x5x32 5x5x6 QUAD 5x5x8 QUAD 5x5x12 QUAD 5x5x16 QUAD 5x5x5 5x5x5 5x5x5 5x5x5 5x5x5 5x5
950-2400
47-862
109 -
115
105 - -
-
-
25 ± 4
-
-
27 ± 2
-
-
7
-
-
6
- 10 ± 5 - 12 ± 5 - 4 ± 2 - 5 ± 5 - 8 ± 4 -1,5 ±0,5 - 4 ± 1
11
- 7 ± 3 - 10 ± 3 - 3 ± 1 - 5 ± 2 -1,5 ±0,5 - 4 ± 1
17
- 5 ± 5 * - 5 ± 5 * - 5 ± 5 - 5 ± 5 - 15 ± 3 - 17 ± 3 - 21 ± 3 - 26 ± 3 -
-
- 9 ± 5 * - 12 ± 3 * - 8 ± 5 - 10 ± 5
- 5 ± 5 * - 8 ± 5 * - 3 ± 5 - 3 ± 5
- 12 ± 1 - 15 ± 1 - 20 ± 1 - 25 ± 1 - -
>30 >25
>25
250 500 250 250
1-1
12 - 12
In-Out / Out-In ** In-Out / Out-In In-Out / Out-In**
-
In-Out /
Out-In
200 ± 15 235 ± 25 65 ± 5 105 ± 10 130 ± 10 - -
33 *** --
–5….+45 ºC
IP20
1200 1600 400 765 800
400 330
140x383x30 140x510x30
140x120x30
140x255x30
140x120x 30 140x120x30
NEVOswitch 5x 6
Ejemplo de aplicación 1 / Example of implementation 1
4
714503
SATELLITE MULTISWITCH
MULTISCHALTER
TERR.
H-LOW H-HIGH
V-HIG H
2
3
15
6
7
8
5x5x8
H-LOW H-HIGH
V-HIG H
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 8 x 47 - 2400 MHz
MADE IN SPAIN
Art.Nr MS58C
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
SAT STB
T
747202
SPU44EN
714501- MS54C
714502 - MS56C
714503 - MS58C
714504 - MS512C
714505 - MS516C
714506 - MS524C
714507 - MS532C
732210
Modo de instalación / Installation mode
1
1
2
2
3
3
7
Ejemplo de aplicación 2 / Example of implementation 2 Ejemplo de aplicación 3 /Example of implementation 3
4
714503
SATELLITE MULTISWITCH
MULTISCHALTER
TERR.
H-LOW H-HIGH
V-HIGH
2
3
15
6
7
8
5x5x8
H-LOW H-HIGH
V-HIGH
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 8 x 47 - 2400 MHz
MADE IN SPAIN
Art.Nr MS58C
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
SAT STB
T
747202
SPU44EN
714501- MS54C
714502 - MS56C
714503 - MS58C
714504 - MS512C
714505 - MS516C
4
714403
SATELLITE MULTISWITCH QUAD
QUAD MULTISCHALTER
TERR.
2
3
15
6
7
8
5x5x8
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 8 x 47 - 2400 MHz
H-LOW H-HIGHV-HIGH
Art.Nr MS58NCQ
MADE IN SPAIN
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
H-LOW
17V
V-HIGH
12V 22KHz
H-HIGH
17V 22KHz
SAT STB
T
747202
SPU44EN
714402 - MS56NCQ
714403 - MS58NCQ
714404 - MS12NCQ
714405 - MS16NCQ
732210
NEVOswitch 5x 8
Ejemplo de aplicación 4 / Example of implementation 4
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
SLOPE
ADJUST
GAIN
ADJUST
4 x 950 - 2400 MHz
1 x 5 - 862 MHz
5x5
AMPLIFIER
VERSTÄRKER
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
VDE
714509
Art.Nr MS530VGQ
MADE IN SPAIN
POWER
12V
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
SLOPE
ADJUST
GAIN
ADJUST
4 x 950 - 2400 MHz
1 x 5 - 862 MHz
5x5
AMPLIFIER
VERSTÄRKER
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
VDE
714509
Art.Nr MS530VGQ
MADE IN SPAIN
POWER
12V
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
SLOPE
ADJUST
GAIN
ADJUST
4 x 950 - 2400 MHz
1 x 5 - 862 MHz
5x5
AMPLIFIER
VERSTÄRKER
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
VDE
714509
Art.Nr MS530VGQ
MADE IN SPAIN
POWER
12V
4
714503
SATELLITE MULTISWITCH
MULTISCHALTER
TERR.
H-LOW H-HIGH
V-HIGH
2
3
15
6
7
8
5x5x8
H-LOW H-HIGH
V-HIGH
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 8 x 47 - 2400 MHz
MADE IN SPAIN
Art.Nr MS58C
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
4
714501
SATELLITE MULTISWITCH
MULTISCHALTER
TERR.
H-LOW H-HIGH
V-HIGH
2
3
1
5x5x4
H-LOW H-HIGHV-HIGH
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 4 x 47 - 2400 MHz
Art.Nr MS54C
MADE IN SPAIN
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
4
TERR.
H-LOW H-HIGH
V-HIGH
2
3
15
6
7
8
12
10
11
913
14
15
16
H-LOW H-HIGH
MADE IN SPAIN
4
714505
SATELLITE MULTISWITCH
MULTISCHALTER
H-LOW H-HIGH
V-HIGH
2
3
1
5x5x16
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 16 x 47 - 2400 MHz
Art.Nr MS516C
V-HIGH
V-HIGH
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
I
MAX
0,3A/
SPLITTER MULTISWICH
MULTISCHALTER
TERR.
TERR.
5x5x5
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
H-LOW
H-HIGH
V-HIGH
4 x 950 - 2400 MHz
1 x 47 - 862 MHz
Ref.714905
Art.Nr SAV525G
4
714501
SATELLITE MULTISWITCH
MULTISCHALTER
TERR.
H-LOW H-HIGH
V-HIGH
2
3
1
5x5x4
H-LOW H-HIGHV-HIGH
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 4 x 47 - 2400 MHz
Art.Nr MS54C
MADE IN SPAIN
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
4
TERR.
H-LOW H-HIGH
V-HIGH
2
3
15
6
7
8
12
10
11
9
H-LOW H-HIGH
MADE IN SPAIN
4
714504
SATELLITE MULTISWITCH
MULTISCHALTER
H-LOW H-HIGH
V-HIGH
2
3
1
5x5x12
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 12 x 47 - 2400 MHz
Art.Nr MS512C
V-HIGH
V-HIGH
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
4
TERR.
H-LOW H-HIGH
V-HIGH
2
3
15
6
7
8
12
10
11
913
14
15
16
MADE IN SPAIN
4
H-LOW H-HIGH
V-HIGH
2
3
1
714507
SATELLITE MULTISWITCH
MULTISCHALTER 5x5x32
4 x 950 - 2400 MHz
1 x 47 - 862 MHz 32 x 47 - 2400 MHz
Art.Nr MS532C
20
18
19
17 21
22
23
24
28
26
27
25 29
30
31
32
H-LOW H-HIGH
V-HIGH
V-HIGH
POWER
12V
V-LOW
12V
TERR.
12V
V-LOW
12V
714903
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-20
H-LOW
TAP-20
H-HIGH
TAP-20
V-HIGH
TAP-20
Art.Nr AZ520G
TERR.
TAP-20
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 20dB
714903
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-20
H-LOW
TAP-20
H-HIGH
TAP-20
V-HIGH
TAP-20
Art.Nr AZ520G
TERR.
TAP-20
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 20dB
714903
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-20
H-LOW
TAP-20
H-HIGH
TAP-20
V-HIGH
TAP-20
Art.Nr AZ520G
TERR.
TAP-20
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 20dB
714901
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-12
H-LOW
TAP-12
H-HIGH
TAP-12
V-HIGH
TAP-12
Art.Nr AZ512G
TERR.
TAP-12
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 12dB
714901
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-12
H-LOW
TAP-12
H-HIGH
TAP-12
V-HIGH
TAP-12
Art.Nr AZ512G
TERR.
TAP-12
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 12dB
714902
TAP
SYSTEMABZWEIGER
TERR.
5x
TERR.
V-LOW H-LOW H-HIGH
V-HIGH
V-LOW H-LOW H-HIGHV-HIGH
V-LOW
TAP-15
H-LOW
TAP-15
H-HIGH
TAP-15
V-HIGH
TAP-15
Art.Nr AZ515G
TERR.
TAP-15
4 x
950 - 2400MHz
1 x
47 - 862MHz
MADE IN SPAIN
I
MAX
0,3A/
Tap loss 15dB
747202
SPU44EN
732210
714903 - AZ520G
714901 - AZ512G
714509
MSV530VGQ
714505
MS516C
714503
MS58C
714501
MS54C
714901 - AZ512G
714903 - AZ520G
714509
MSV530VGQ
714504
MS512C
714509
MSV530VGQ
714905 - SAV525G
714903 - AZ520G
714902 - AZ515G
714507
MS532C
714501
MS54C
732210
732210
9
RANGO DE PRODUCTOS PRODUCT RANGE
Ref
Art. Nr. Descripción Description
714501
MS54C Multiswitch 5x4 5x4 Multiswitch
714502
MS56C Multiswitch 5x6 5x6 Multiswitch
714503
MS58C Multiswitch 5x8 5x8 Multiswitch
714504
MS512C Multiswitch 5x12 5x12 Multiswitch
714505
MS516C Multiswitch 5x16 5x16 Multiswitch
714506
MS524C Multiswitch 5x24 5x24 Multiswitch
714507
MS532C Multiswitch 5x32 5x32 Multiswitch
714402
MS56NCQ Multiswitch 5x6 QUAD 5x6 Multiswitch QUAD
714403
MS58NCQ Multiswitch 5x8 QUAD 5x8 Multiswitch QUAD
714404
MS512NCQ Multiswitch 5x12 QUAD 5x12 Multiswitch QUAD
714405
MS516NCQ Multiswitch 5x16 QUAD 5x16 Multiswitch QUAD
714509
MS530VGQ Ampli cador 5x5 5x5 Ampli er
714901
AZ512G Derivador 5x5x5 (12dB) 5x5x5 Tap (12dB)
714902
AZ515G Derivador 5x5x5 (15dB) 5x5x5 Tap (15dB)
714903
AZ520G Derivador 5x5x5 (20dB) 5x5x5 Tap (20dB)
714904
AZ525G Derivador 5x5x5 (25dB) 5x5x5 Tap (25dB)
714905
SAV525G Repartidor 5 x 5 x 5 5x5x5 Splitter
NEVOswitch 5x 10
ES
Instrucciones de seguridad
Condiciones generales de instalación:
Antes de manipular o conectar el equipo leer este ma-
nual.
Para reducir el riesgo de fuego o choque eléctrico, no
exponer el equipo a la lluvia o a la humedad.
Deje un espacio libre alrededor del aparato para propor-
cionar una ventilación adecuada.
El aparato no debe ser expuesto a caídas o salpicaduras
de agua. No situar objetos o recipientes llenos de agua
sobre o cerca del aparato si no se tiene la su ciente pro-
tección.
No situar el equipo cerca de fuentes de calor o en am-
bientes de humedad elevada.
No situar el equipo donde pueda estar sometido a fuer-
tes vibraciones o sacudidas.
Operación segura del equipo:
La tensión de alimentación de éste producto se sumi-
nistra a través de las fuentes de alimentación ref.7321 y
7328 (230V~ / 12V).
Si algún líquido u objeto se cayera dentro del equipo, por
favor recurra al servicio técnico especializado.
Para desconectar el equipo de la red, tire del conector,
nunca del cable de red.
No conectar el equipo hasta que todas las demás co-
nexiones del equipo hayan sido efectuadas.
Do not place the equipment where it may be a ected by
strong vibrations or knocks.
How to use the equipment safely:
The powering voltage for this product is provided by the
PSUs ref.7321 and 7328 (230V ~ / 12V).
If any liquid or object falls inside the equipment, please
contact a specialized technician.
To disconnect the equipment from the mains, pull from
the connector, and never pull from the cable.
Do not connect the equipment to the mains until all the
other connections have been made.
Description of the electrical
safety symbols
To avoid the risk of  re or electric
shock, do not open the equip-
ment.
This symbol indicates that the
equipment complies with the
safety requirements for class II
equipment.
This symbol indicates that the
equipment complies with the
safety requirements for equip-
ment of marked CE.
Descripción de Simbología de
seguridad eléctrica
Para evitar el riesgo de choque
eléctrico no abrir el equipo.
Este símbolo indica que el equi-
po cumple los requerimientos
de seguridad para equipos de
clase II.
Este símbolo indica que el equi-
po cumple los requerimientos
del marcado CE.
EN
Important safety instructions
General installation conditions:
Before handling or connecting the equipment, please
read this manual.
In order to reduce the risk of  re or electric shock, do not
expose the equipment to rain or moisture.
Please allow air circulation around the equipment.
The equipment must not come into contact with water
or even be splashed by liquids. Do not place containers
with water on or near the equipment if it is not
adequately protected.
Do not place the equipment near sources of heat or in
excessively moisture conditions.
DECLARACIÓN DE CONFORMIDAD DECLARATION OF CONFORMITY
DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE
DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI
KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ
FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ
СООТВЕТСТВИЯ www.televes.com
11