Jenn-Air CCG2422 Installation Instructions Manual

Category
Cookers
Type
Installation Instructions Manual

This manual is also suitable for

SEALEOGAScooroPs I c mJENN'AIR.1
CCG2422 AND CCG2522 3036 SHADELAND INDIANAPOLIS,IN46226-0901J
I SPECIAL WARNING: Improperinstallation, adjustment,alteration, service, maintenance oruse of
appliance can resultin serious injury orproperty damage.
IMPORTANT: Dimensions Shown in Both Inches and Centimeters. 30" MODEL
NOTICE TO INSTALLER: Leave these instructionswith the appliance.
NOTICE TO CONSUMER: Retain theseinstructions for future reference.
.911e",.=...__/76.2cm
1.43 cm
Entrance Min.
37h_. 2%"
8.73cmj_,_ _ _ _ ,i 6.67cm
I I-
f_MANIFOLD I
I ENTRANCEI
,',,S"27;
4,21 cm
IMPORTANT: Besuretheappliancebeing instafled isequipped for 'thegas to besupplied. Referto serial plateonundersideofbumer
box for this information,Do not attempt to convert this appliancefor use with a gas other than thetype specified.
36" M()DEL
NOTICE TO INSTALLER: Leave these instructions with the appliance.
NOTICE TO CONSUMER: Retain these instructions for future reference.
36"
9he"
37/1(
673cm_,r_r,_, _ _ j_ 25/_.
6.67 cm
I I-
-- _'_c'_- MANIFOLD . "_-
I EN'rFIANCE
i 14"
1lS/_.• 36.57cm _.
4.05cm
IMPORTANT: Be sure the appliance being installed is equipped for the gastobe supplied.Refer to sedal plate onunderside of burner
box for this information. Do not attempt to convert this appliance for usewith a gas other than the typespecified.
IMPORTANT
CUTOUT
DIMENSIONS
ARE
CRITICAL 12/95
LOCATION OF YOUR JENN-AIR APPLIANCE IMPORTANT PREPARATION SUGGESTIONS
Locatethis appliance away from combustiblematerials such as win- 1. Chamferall exposededgesofdecorativelaminateto preventdam-
dow curtains and combustible wall decorations,agefrom chipping.
2. Radiuscomersof cutout and file to insuresmooth edgesand pre-
Minimum horizontal clearance between the edge of theapplianceand vent corner cracking.
combustible construction extending from the cooking surface to 16" 3. Rough edges, insidecorners which have not been rounded and
(45.72cm) abovethecooking surface is forced fits can contributeto cracking of the countertop laminate.
4. Countertop must be supported within 3" (7.62 cm) of cutout.
1" (2.54 cm) at rear
2" (5.08 cm) atsidesINSTALLATION OF APPLIANCE:
Theinstallationof thisappliancemustconformwithlocalcodesor, in
(Dimensionsapplyto both30"and 36"widemodels) theabsence oflocalcodes,withtheNationalFuel GasCode, ANSI
Z223.1--Latest Edition,or, in Canada, CAN/CGA-B149 Installation
Fig. 1 _".............. [". Code, LatestEdition.
=I
'! _ This appliance,wheninstalled,mustbe electricallygrounded inaccor-
l"cm) 7,__ __,.
_T__ji18" dance withlocal codesor,inthe absenceoflocalcodes,withtheNa-
(2.54
145.72cm) tionalElectricalCodeANSI/NFPANo.70--Latest Edition,or,in Canada,
currentCSA Standard C22.1Canadian Electrical Code,Part 1.
-- All supply piping,except as noted, should usecommon National Pipe
T-(" "
'\ _ Thread (N.P.T.). Forall pipe connectionsuse an approved pipe joint
(3.811v2"Min.cm) (5.082"cm)'--__"compoundresistantto theactionofLP gas.
CAUTION: WarrantyisvoidonJenn-Airequipmentinstalledotherthan
INSTALLINGCABINETRY OVER YOUR asrecommendedby manufacturer.
JENN-AIR COOKTOP This applianceis designedfor usewiththe appliancegas pressure
A= 30"(76.2 cm) minimumvertical clearancebetween cookingsur- regulatorsuppliedwiththisappliance.Itmustbeinstalledinthegasway
faceandconstructionabovetheappliance.Thisclearancemay beahead ofthegas manifoldentrance.Itispresetforusewithnaturalgas
reducedto not lessthan24 inches(60.96 cm) by protectingtheand mustbe converted,as describedon page 6,for usewithLP gas.
undersideofthecombustiblematerialor metalcabinetabovethe(see Fig. 10 and 11.)
cookingsurfacewith not less than1/4 inch(.635 cm) insulating
mitlboardcoveredwith sheetmetalnotlessthan0.0122 inchthick* This applianceis designedto operate at a pressureof 5 inches of
B = 13"(33.02 cm) maximumdepthofcabinetsinstalledabovecook- watercolumnon naturalgasor,ifconvertedfor usewithLP gas(pro-
paneorbutane),10 inchesofwatercolumn.Makesurethisapplianc
ingtop. _is suppliedwith and adjustedfor the type of gas for whichit is d_
signed.
This appliancewas adjusted at the factoryforusewithnatural gas. If,
Fig. 2at any time, this appliance isto beusedwith adifferenttype of gas, all
of theconversion adjustments described on pages 5 through 7 must
_-bemade byaqualifiedservicetechnicianbeforeattemptingto operate
A • B---,- the cooktop on that gas. Naturalgas shouldbesuppliedto theappli-
ance pressureregulatorat a linepressurebetween6 and 14 inchesof
watercolumnor, ifconvertedfor LPgas, between 11 and 14 inches.
I _ I WARNING: Ifthe line pressuresupplyingthe appliance pressure
I regulatorexceeds 14"W.C. (anygas), anexternal regulatormustbe
Avoid use of cabinetsabovecooktop for storagespaceto eliminateinstalled in the gas line ahead of the appliance regulator to reduce
associated potential hazards such as reaching over open flames, thepressureto no more than 14" W.C. Failureto do this can result
in malfunction and damageto the appliance.
PREPARATION OF COUNTERTOP Insurethis applianceisadjustedforthetype ofgas suppliedto it and
Thecountertopcutoutmustbepreparedaccordingtotheillustrationon that thegas supply pressureto the appliancepressureregulatoris
page1 oftheseinstructions, withinthe properpressurerange.
CAUTION: Cutout dimensionsarecritical. Dimensionsmustbe mea- Ifthisisa 36"widemodel,or ifitisa 30"wide modelandnoother
suredandcut accuratelyto within + 1/16"(.159 cm) to ensure proper applianceisto beinstalledinthecabinetrybelowit, proceedas
fit. instructedunder paragraphI.
Ifthisisa 30"widemodelanda Jenn-AirModelW3OXXXorW131
ElectricWallOvenistobeinstalledincabinetrybelow,proceedas
*Jenn-AirOver-the-Rangemicrowaveovens(model#M418 and M438) instructedunderparagraphII.
havebeen listedbyUL for useoverGas and ElectricRanges. WhenDo notremoveprotectivecapfrompipestubat manifoldentranc,-
properlyinstalledata minimumheight of66 inches(167.64 cm) from untilreadyto joingassupplypipingto appliance.
thefloortothetop ofthe microwave,theclearancetothe cookingsur-
faceatthe centerwillbe 133Ainches(34.93 cm).NOTE: InCanada, gasutilizationcodesprohibit useofstreet elbows.
Use standardpipe elbowsand make modificationsto these instruc-
tionsas necessary.
2
I. IF NO OTHER APPLIANCE IS TO BE INSTALLED BELOW Joinel/2"NPTpipeeIbew(Iocanyavailable)tothemalethreadsatthemani-
THIS COOK'FOP foldentrance.Whenjoined,causetheopenthreadsoftheelbowtofaceto-
Jointheappliancepressureregulatorsuppliedwiththisappliancetotheen- wardtheleftsideoftheappliance.Installtheapplianceinitscountercutout,
trancethreadsoftheGasManifold.Theapplianceregulatorismarkedwitha
directionalarrowindicatingcorrectdirectionofgasflow.Ensuretheappliance Joina 1/2"NPT pipenippletotheelbowusinga pipesectionofsufficient
-egulatorisinstalledwiththearrowpointingtowardthegasmanifoldentrance, lengthto extend,horizontally,beyondtheleftsideofthewalloven. (Toac-
)htantheapplianceregulatorto20to30ft-lbsoftorque, complishthisitmaybenecessarytoextendthepipesectionintoadjacent
cabinetry.)Joinaddtiona 1/2"NPTebow(s)andpipenipples,as necessary,
IMPORTANT toaccomplishthefollowing:
INevertightentomorethan35ft-lbsoftorque.Alwaysuseanapprovedpipe
jointcompoundresistanttotheactionofLPgas. 1. Jointheoutletoftheappliancepressureregulatorsuppliedwiththisappli
ancetothemalethreadsofthenewlyinstalledgassupplypiping.Instal
Installtheappliancein itscountercutout,theapplianceregulatorina locationwhichwillbeaccessiblebesideor
belowthewall oven.Insuretheapplianceregulatoris installedwith its
Makethegasconnectiontotheinletoftheappliancepressureregulatorwith directionalarrowpointingin thedirection ofgasflow.Tightenthe appli-
1/2"malepipethreads, anteregulatorto 20to 30ft-lbsoftorque.
Installa manualshut-oftvalveinanaccassibIelocationinthegaslineahead I IMPORTANT I
oftheappliancepressureregulatorandexternaltothisappliancefortheput-INevertightentomorethan35 ft-lbsoftorque.Alwaysusean approved
poseofturningonorshuttingoffgastotheappliance, pipejointcompoundresistanttotheactionofLPgas.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalveto 2. Locateandjoina manualshut-oftvalveinanaccessiblelocationinthe
thegassupplysource.Assureallpipejointconnectionsaregastight,gaslineaheadoftheapplianceregulatorandexternaltotheappliancefor
thepurposeofturningonor shuttingoffgasto theappliance.
IMPORTANT I
Testelijointsforgasleakswitha soapandwatersoluticoorotheraccepted Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalvete
eakdetectionmeans.Nevertestforgasleakswithanopenflame,thegassupplysource.Assureallpipejointconnectionsare gastight.
ILLUSTRATIVE GAS SUPPLY PIPING IMPORTANT
Testalljointsforgasleakswithasoapendwatersolutionorotheraccepted
Fig. 3 leakdetectionmeans. Nevertestforgasleakswithanopenflame.
(NOOTHERAPPLIANCEBELOWCOOKTOP)
IILLUSTRATIVE GAS SUPPLY PIPING
BURNER BOX
(REAR OFAPPLIANCE)0h/ALLOVENINSTALLEDBELOW30=COOKTOP
Fig. 4
L_tJBURNER BOX
MANIFOLD
ENTRANCE/--i{--.- (REAROFAPPUANCE)
MANIFOLD
APPLIANCE -- ENTRANCE
PRESSURE /
REGULATOR
I I LEFT SIDE
,
iALLPIPEJOINTS]PIPINGPASSESTHROUGH
1/2"N.P.T./MANUAL .NIPPLES
Lengths
SHUTOFF I to,u_ I 112"N.P.T. I
ALLPIPE JOINTS
VALVE I
I APPU E MANOAL
PRESSURE SHUTOFF
REGULATOR VALVE
-OI E}-
--- -m"TO GAS _"GAS
ELBOW INLET L_INLET
APPROXIMATECROSS SECTION
PROFILEOF WALLOVEN
I1. IF THIS IS A 30" WIDE COOKTOP AND A JENN-AIR,
MODEL W30XXX OR W131, ELECTRICWALL OVEN Note,regardingFig.4,above:
I Forconveniencainserviceagreundjointunion(notshown:locaHyavail,
ISTO BE INSTALLED BELOW THIS COOKTOP. able)shouldbeincludedinthepipingillustratedin Fig.4, ina Ioca_o
mostpracticalfortheinstallation.Generally,apracticallocationisinth
NOTE1: Thisapplianceand itsgasandelectricalsupplysourcesmustbe cabinetbelowthisappliance,nearthemanifoldentrance,ratherthani:
installedbeforethewailovenisinstalled.Seeillustration(ElectdcalWiring anadjoiningcabinet.
formation- page4; Fig.6)forrecommendedelectricalsupplysourceIoca- • IfthealternativepipingmethodshowninFig,5 isselectedforthe instal,
ons. lation,nogroundjointunionisrequired.(Theflexibleapplianceconnec
totillustratedprovidestheunionjointsnecessaryforservicing.)When
NOTE2: Itmaybe necessarytoextendgassupplypipingforthisappliancedividingwallispresentanda flexibleconnectorisuseditisrecomrnendec
intoadjacentunder-ccuntercabinetrywhenawallovenisinstalledbelowthis forconvenience,inbothinstallationandservice,theflexibleconnector
appliance, itself,passthroughthedividingwall.Anyflexibleconnectorusedwiti'
this appliancemustsatisfyall requirementsstated In thetext ac
companyingFig,5.
3
ALTERNATIVEPIPING METHODS TO CONNECT PRESSURE TESTING
APPLIANCE TOGASSUPPLYThe appliance must beisolated from thegas supplypipingsystem byclosing
Unlessprohibitedbylocalcodes orordinances,anewA.G.A. -Certified,flex-its individualmanualshut-offvalve duringanypressuretestingofthegas sup-
iblemetalappliance connector may be usedto connectthis appliance to its ply pipingsystemat test pressures equalto orless than 1/2 PSIG (3.5 kPa).
gassupply.Theconnectormust havean internaldiameternotlessthan nominal
1/2"NPT pipeand be nomore than 5 feet in length. A1/2"NPT x 1/2" flareThis appliance, as well as its individualshut-offvalve, mustbedisconnected
unionadapter isrequiredat each end oftheflexibleconnector. If a flexiblefrom thegassupplypipingsystemduringany pressuretestingofthesystemat
connectorJsusedassurethatboththeapplJancepressureregulatorandmanualtest pressures inexcess of1/2 PSIG (3.5 kPa).
shut-offvalveare joined solidlyto other permanent hard piping (either gas
supply piping or the appliance manifold) so as to bephysicallystationary.When checkingapplianceregulatorfunction,makecertain pressureofnatum_"
See illustrationsbelow: gas supplyis between6 and 14 inches of water columnor, ifconvertedfor LP
gas, between11and 14 inches.
ILLUSTRATIVE ALTERNATIVE PIPING ELECTRICAL WIRING INFORMATION
This apHanceisequippedwitha groundedtypepowercord.A groundedoutlet
Fig. 5 mustbeprovided. _tisrecommended,for convenience,theoutletbelocated
(with reference to Fig.6) as inAorB, below:
A. Ifno other applianceisto be installed below this appliance:
within eithertheshaded area or thecrosshatched area shown in Fig.6,
B,Ifa Model W3OXXX or W131 electric ovenisto be installedbelow this
appliance,either:
1) withinthe cross hatchedarea ofFig.6, or,
I 2) withinan adjacent cabinet.
I I
-.q--App,anceFig.6
PressureReoul_t0rsupplied ,___2s/s.
Observedirectionality
utGasF0w :6.67 cm
I
i_Flare Pipe31/z"(8.89cm)wide 36"
Ftare Union Nipple
Union Adapt_r slats when a wall 91.44cm
Adaptor ovenisinstalledBe-
Elbowlow 30" /
Flexible IA
Appliance (5ft.rn_o_)
) CABINETBO'I-FOM1"
_DimensionA:
I I W3OXXX: 5Y_"(13.97cm)
orAdaptor Ifawall oven )stobeinstalledbelowthisapplianceand thecounter uNt's out/at
zI istobemountedwithinthecrosshatched area of Fig. 6:
Gas _-91-- AppliancePressure t) The cabinet's lowerfrontpanel,belowthe oven, must be made remov-
Shut-oft j(('_ _J_Regulator,supplied ableforaccessto theoutlet.
ObServe
Vat,s lirecUonality 2) A clearance hole forthe powercord's plug (11,_,,[3.18cm] diaisrecom-
I_olGasRow) mended) must be provided throughtheoven's floorsupportshelf and, if
½'NPTPipeI necessary, through the slats supportingthe shelf. The clearance hole
"91- stationary _should be locatedas near as practicaltothe rearoftheshelfand (ifthe
I_J supplypipe _ _' NPT oven is modelW3OXXX) as near as pracflcal tothe left rearcomer.
Pipe 3) When model W3OXXX ismounted below thisappliance,and ifthe power
Nipple outletfor thisappliance isto belocated in thecrosshatchedarea ofFig.
I6, itisrecommendedthe powercord beroutedthroughtheexternalver-
tical clearance channel at theleft rear ofthe oven. The channel'scress
Gas sectionisapproximately 4.2" x 2.25" (10.7 x 5.7 cm),extendingthe full
Shut-0ff
Valve heightoftheoven. (Model W131 provides a similar,but larger,vertical
channel nearthe center ofthe mainbackof the oven.)
I
_1-_' Iftheoutletisto be mountedineither a left or rightadjacent cabinet, a clear-
NFr
Pipe
Stationary ancehole,as describedabove, must be providedinthe dividingwall between
supplyppe thecabinets.Fig4; page 3, illustratesa typical (left side) dividing wall. The
clearancehole(notshownin Fig.4) can be (ocatedas isconvenientinthis left
CAUTION: Do not attempt to attach theflexible connectordirectly to an wallorin thecorresponding fightwall.
external pipethread. Connectionrequiresflareunionadapters.
IIMPORTANT
Testallconnections forgas leaks withasoap andwater solutionor other
accepted leak detectionmeans.Never testfor gasleaks withan open
flame.
In planningany installation,notethatthe free lengthofthisappliance'spower Step 5: LocatetheLP orificespudpackettaped tothe undersideofth_
cord,extendingbeyondapoint3_" (9.53 cm) left ofthe nominalcenter of the burner box. Thespuds arezinc-plated and have smallhum
rearwall oftheburnerbox, whenviewed fromthefront ofthe unit,isapproxi- bets stampedon the side. This number codesthe orificediem
mately46" (117 cm). eterand its correctburner location.The followingillustration
showcorrectLP orificespud locationfor 4burner and 5 burne
models,respectively.
WARNING
ELECTRICALGROUNDING INSTRUCTIONS INSTALLATION OF LP (ZINC-PLATED) ORIFICE
THIS APPLIANCE IS EQUIPPED WITH ATHREE PRONG GROUND-
ING PLUGFORYOUR PROTECTIONAGAINSTSHOCK HAZARDANDSPUDS
SHOULD BE PLUGGED DIRECTLYINTO A PROPERLYGROUNDED
RECEPTACLE.DO NOTCUTOR REMOVETHE GROUNDINGPRONG 4 Burner model (30" Wide)
FROMTHIS PLUG.Fig. 8
WARNING
THIS APPLIANCE MUST BE DISCONNECTED FROM ITS ELECTRI-
CALSUPPLYATTHE WALLRECEPTACLE BEFORE SERVICING THE
APPLIANCE.
CONVERTINGAPPLIANCE FOR USE WITH LP GAS
WARNING
Propane conversion is to be performed by a JENN-AIR AUTHORIZED
SERVICER (or other qualified agency) inaccordance with the O
manufacturer's instructionsand all codes and requirements oftheau-
thorityhaving jurisdiction. Failure to follow instructionscould resultin (_ (_
seriousinjuryor propertydamage. The qualifiedagency performingthis
workassumes responsibilityforthisconversion.
WARNING
Electricalpowerand gas mustbe turnedoffpriorto conversion.
is appliancewasadjustedat thefactoryfor usewith natural gas. Tocon-
,rtitforuse withLP gas (propane or butane),each ofthe following modifica-
,,onsmustbeperformed: 5 Burner Model (36" Wide)
A. Replace all orifice spuds Fig. 9
Step 1: Removethegrates and burner heads.
Step2: Withan adjustablewrench,unscrewand removethebrasscollar
nuts(Fig. 7).
Step 3: Trim a small pieceofmasking tapeto the sizeofa dimeand
affix itover the end of a 9/32"nutdriver.
Step 4: Firmlypress the nut driverover theorificespud (Fig. 7) and
loosenspudbyturningcounterclockwise.Carefullyliftnutdriver
out ofburnerthroat. Orifice spud shouldbe capturedinthe
recess. Repeat this step foreach burner.
Fig. 7 REMOVAL OF ORIFICE SPUD ©©©
© ©
BRASS
COLLAR
NUT "_(_iJ %2"NUTDRWER
PIECEOFMASKING
END Step 6: With the masking tapeet/ll in place in therecess of the rl
OF DRIVER driver,pressan LP odfice spud(zinc-plated) intothe recess:
I__ INDENTATION that itissnugly captured,
BURNERBASE Step 7: Carefully installthe orificespudinthe appropriate burnerthrc
by turningclockwise totighten,33ghtentoatorqueof 15 to
inch-lbs.
ORIFICESPUD Step 8: Replace cylindricalbrass collar nutsand tightentoa torque
of6Oin.-Ibs. Replace burear heads and grates.Index each
grate toits burner pan.
Step 9: Save the odfices removed from the appliance forfuture us_
5
Invertcap in appliancepressure regulator C. LowFlame Adjustment
(See Figures10and 11.) Withthe applianceinstalled,theappli- (See Figure 12):
ance regulatorshouldbe locatedas shownin Fig 3 or 4.Identify
the type ofappliance regulatorontheunit andfollowthe instruc-This applianceisshippedfromthefactorywithlowand mediumflame
tions intheappropriateillustration, settingsadjustedforuse withnatural gas, If furtheradjustment is
necessa_, orto readjustforusewith LP,proceedas follows:
CONVERSION OF MAXlTROLAPPLIANCE
PRESSURE REGULATOR 1. Lightburnerand set controlknobfor lowflame.
Fig, 10 APPLYDOWNWARD
FINGERPRESSURE 2. Removecontrol knobfromvalvestem.
ATDISCEDGESTO
R,_LPREPL_CEPIN/NCA_CAUTION: NEVER USEA METALBLADETO PRYKNOBOFF.
_ _ IF KNOBCANNOTBEEASILYREMOVED,TUCK THE FOLDS
CONVERTE APPLY8tDEWARD
__ _ CAP [,_FINGERPRESSUREv.,-_v_ OFACLOTH DISHTOWEL UNDER THE KNOBANDPULLTHE
_"ANDPIN,Jt_"_- TOREMOVEPiN _ TOWEL UPWARDWITH STEADY,EVEN PRESSURE.
NAT LP 3. Inserta slender,thin-bladescrewdriverintothe recessat centerof
_ __valvestemand engagebtadewithslotin adjustingscrew.
4. Turn canterstemadjustingscrewto set flamesize
... clockwiseto reduce
...counterclockwiseto increase.
5.Replacecontrolknobwhenadjustmentiscomp)eted.
Properadjustmentwillproducea stable, steadyblueflameofminimum
CONVERSION OF HARPER-WYMAN size. The finaladjustmentshouldbecheckedbyturningknobfromhigh
'ig. 11 APPLIANCE PRESSURE REGULATOR to lowseveraltimes withoutextinguishingthe flame.
Withaquarter,engage
_ 1 slotandrotatecap f/8 of Thisadjustment,at lowsetting,wNIautomaticallyprovidetheproperflame
_'=_,_--,=_ / a turncounterclockwise,size at medium setting.
_. " _to removecap, Turn cap
-install Fig. 12COUNTERCLOCKWISE
TO INCREASEFLAME
TO REDUCE
FLAME SIZE
VALVE
Natural Setting LP Setting STEM
6
After ConversionStepsA, B and C have been completed,checkthe INSTALLATION OF NATURALGAS (BRASS) ORIFICES SPUDS.
appearanceofeach burner'sflameat the Hi and Lo settingsagainst
Fig.13. Iftheflames appeartoolargeortoo small, revieweach stepto 4 BURNER MODEL (30" WIDE)
make sureitwas completedcorrectly.
FLAME APPEARANCE AT HI AND LO Fig.14
Fig. 13 _._.,
off
M_ oo
©©
o_
TO CONVERT APPLIANCE FOR USE WITH
NATURAL GAS Fig. 15 s BURNER MODEL (36" WIDE)
IWARNING I
Electricalpowerand gasmustbeturnedoffpriorto conversion.
if this appliancehasbeen convertedfor usewith LPgas, each ofthe
lowingmodificationsmustbe performedto convertthe unitback to
_turalgas.
A. Replace all orifice spuds
PerformStepst through4 on page5.
For Step 5: Locatethe brass naturalgas orificespudswith small C)© ©
numbersstampedontheirsidesthat wereodginallyinstalledinthis© O
appliancebefore itsconversionfor use with LP gas. Observethe
small numbers stamped on the sides of the spuds and notethe
correctbumer locationfor eachspudas shownin Figs. 14 and 15.
CompleteSteps6 through9 on page 5 to completetheinstallation
ofnaturalgas mainspudsintheircorrectionlocations.
Save the odficasremovedfromtheapplianceforfutureuse, They
willbe neededifthis applianceis again convertedfor use withLP
gas.
Invert cap inappliance pressure regulator, (See Figs.10 & 11.) Fig. 17
Withthe applianceinstalledthe applianceregulatorshouldbe Io-5 BURNER MODEL
catedas shownineitherFig3 or Fig4(page3). Identifythetype of _\
illustration.appliancersgulatorandfollow theinstructionsin the appropriate /_ (_ _
Adjust Low Flame as Instructed on Page 6 in Item C._ _ __ t
sr StepsA,Band C havebeencompleted,checktheappearanceof Burner Input Rates -All Gases (btu/hr)
;h burner'sflame at the Hi and Lo settingsagainst Fig. 13. Ifthe Location Hi Lo
nes appeartoo largeor too small,makesure all stepswerecom- Right Front 12,000 1,500
ted correctly. Right Rear 9,100 1,050
Center 6,500 830
Left Front 9,1001,050
JRNER IGNITION AND AUTO-REIGNITION Left Rear 10,500 1,500
isapplianceis equippedforelectronicauto-reignitionbymeansofa
_rkigniterlocatedat therear of each burner. The burnersarede-
ned to light at anyvalve rotationthat admitssufficientgas flowto
)port a flameand to automaticallyrelight followinga lossof flame
.=to a draft or other adverse condition. This feature is provided as a
wenience and isnot intendedasasafetyfeature.TOP GRATE PLACEMENT
The top grates onthis cooktophaveundersideprojectionlugsdesigned
LUTION:Never usea metalbladeto pryoffa controlknob.Ifa knob tonestinmatchingdepressionsinthespillovertrays. Duringgrateplace-
lnot beeasilyremovedtuckthefoldsofa cloth dishtowelunderand mentalwayspositiongratestomakethisengagement. Correct indexing
_undthe knoband pullthe towelupwardwithsteadyevenpressure, ofgratesabove burnerportswillpreservethegrates'appearanceand
helpassurelonglife.
LUTION: Never covercontrolknobsor surroundingcontrolsurface
h utensils,towelsor other objects.Never obstructfree air passage
stthecontrolknobs.Theknobopeningshavebeensized toproperly
ltrol air entryto theinterioroftheapplianceduringoperation.
isappliancehas noair shutters.Primary air adjustmentsare unnec-
;ary. The burnersare designedto provideoptimumaerationfor all
_es withoutair shutters.When operatingproperly,burnersshould
)duceclearly defined,even blueflames. Iftheflames have yellow
or arehazyandotherwiseappearto haveinsufficientair,obtainthe
"vicesofa qualifiedservicetechnician.
ecifiedinputratesare as shownin Figures16 and 17, below.
Fig.16
4 BURNER MODEL
Burner Input Rates - All Gases (btu/hr)
Location Hi Lo
Right Front12,000 1,500
Right Rear 9,100 1,050
Left Front 6,500 630
Left Rear 10,500 1,500
V LF
BK (RIBBED) N (NERVURE) SPARKMODULE REIG= ]3 = " AVG
G V _ MODULED'ALLUMAGE
BK (SMnDTH) N (LISSE) S_ __ __ R LR
AO
_ _ _ , , _ _ Y ; = RR .
|
6 7 8 9101112 J AD
4 _ AVD
VALVE SVITCHES
CDNTACTERUSDE RDBINET
RF J_ BL
AVD /IGNITERS
BK RR /_ Y ALLUMEURS
NAD J
LR _ R
AG /
LF /j W ORIFICESPUDSIZES
AVG B TAILLESDESnRIFICES
RFIAVD iGG 105
RRIAD 140 89
WIRINGDIAGRAM210396A LF/AVG 118 74
PLANDEC_BLAGE LRIAG 156 99
CAUTIDN:Thiswlrln9 dlagromICor30'modelonly,
ATTENTII]N:Plan de c_blage pour [e modele de 30 po seulemen±,
IGNITERS
ALLUMEURS
BK (R]BBED) N (NERVURE) ]
I W LF
G V [ I, I) " " AVG
BK (SMnBTH) N(LISSE) _ _ _.
SPARK MODULE
MFIDULED'ALLUMAGE Y . =RR .
VALVE SVITCHES _ JAD "
CONTACTERUSDE RBBINET _ _
9 101112 13 14 15 16
RF /A N HIll IH I
AVD l N =
BK RR /_Y
N AD J i]
LR J_ R
LF _ W DRIFICESPUDSIZES
AVG B TAILLESDESDRIFICES
mmmmm JENN-AIR Burner/BrOteurRF/AVDN_t,G_s/Gez]66n_t, LP G_s/G_z105PL
RRIAD _nd LFIAVG 140 89
VIRINGDIAGRAM210397A CEN 118 74
PLANDE CABLAGE LR/AG 156 99
CAUTIF1N:This wiring dlagrom {or 36' model only,
ATTENTIFIN',Plan de c_blage pour le modele de 36 po seulement,
9
REQUIRED ADJUSTMENTS ATTIME OF INSTALLATION
The installationof this appliance must conform with local codes, or in the absenceof local codes, with
the latest edition of the National Fuel Gas Code ANSI Z223.1 USA or current CAN/CGA-B149
INSTALLATIONCODE.
_-_ Thisappliance was manufacturedforusewithNaturalGas. If LP gas isthefuel ofchoice,followthe
conversionto LPprocedurefound inthe installationinstructions.
Testall externalconnectionsfor gasleaks. Never test for gas leaks with an open flame.
---] Testall electrical connections.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Jenn-Air CCG2422 Installation Instructions Manual

Category
Cookers
Type
Installation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI