Toro Diagnostic Cable Kit, DD Series Directional Drill or RT Series Traction Unit Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Toro Diagnostic Cable Kit, DD Series Directional Drill or RT Series Traction Unit Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FormNo.3379-504RevB
DiagnosticCableKit
DDSeriesDirectionalDrillorRTSeriesTractionUnit
ModelNo.127-8401
InstallationInstructions
WARNING
CALIFORNIA
Proposition65Warning
ThisproductcontainsachemicalorchemicalsknowntotheStateofCaliforniato
causecancer,birthdefects,orreproductiveharm.
Installation
Note:UsethiskitasadataconnectionbetweentheECU(electroniccontrolunit)onyourmachineandthecomputerthat
youwillusetoanalyzethecomponentfunctionsofthemachine.Inadditiontothiskit,youwillneed2softwareapplications
installedonyourcomputer:ThePlus+1GuideServiceToolcreatedbySauerDanfossandthesystemdiagnosticsoftware
createdbyTheToro®Company.
PreparingyourComputer
DownloadingthePlus+1GuideService
ToolSoftware
1.Onyourcomputer,navigatetotheToroCompany
PortalforPlus+1GUIDEServiceToolSoftware&
Licensetodownload.
2.NavigatetoGatewayPartsandServiceCenter.
3.ClicktheServiceLibrarytab.
4.ScrolltotheUndergroundEquipmenttab.
5.ClicktheDiagnosticSoftwarelink.
6.ClickthePlus+1GUIDEServiceToolSoftware&
Licenselinktodownloadit.
7.Whenthedownloadiscomplete,thePlus+1iconwill
appearonyourdesktop.
8.Onyourcomputer,navigatetotheToroCompany
PortalforthecorrectDiagnosticle.
9.NavigatetoGatewayPartsandServiceCenter.
10.ClicktheServiceLibrarytab.
11.ScrolltotheUndergroundEquipmenttab.
12.ClicktheDiagnosticSoftwarelink.
13.Clicktheproducttype.
14.Clickthemodelnumbertoobtainthecorrect
diagnosticle.
15.Savethediagnosticletoyourdesktop.
©2014—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA
AllRightsReserved
*3379-504*B
InstallingtheToroSystemDiagnostic
Software
Thisproceduredescribeshowtoinstallingthesystem
diagnosticsoftwarefromtheGatewayPartsandService
CenterwebsitefortheToroCompany.
1.GototheGatewayPartsandServiceCenter.
2.OpenthePlus+1GUIDEServiceTool.
3.Clickonthediagnosticicononthetoptoolbar.
4.ThediagnosticprogramwillloadinPlus+1GUIDE
ServiceTool.
5.Refertoform2000–4002ToroPlus+1Diagnostic
SoftwareInstructionalManualforfurtherinformation.
InstallingtheAdapterHarness
andDiagnosticCable
1.Selecttheharnessadapter(Figure1)foryourmachine
byusingthetablebelow .
AdapterTable
ProducttypeProductNameAdapterHarness
Type
DirectionaldrillDD12153-pinconnector
DD14163-pinconnector
DD20243-pinconnector
DD32383-pinconnector
DD40459-pinconnector
RideonTrencherRT9609-pinconnector
RT10009-pinconnector
RT11609-pinconnector
RT12009-pinconnector
G024334
1
2
3
4
5
6
3
4
Figure1
1.3-pinconnector
4.9-socketconnector(end
view)
2.3-pinconnector(endview)
5.9-pinconnector
3.9-socketconnector
6.9-pinconnector(endview)
2.Connectthe9-socketconnectortothe9-pinconnector
ofthediagnosticcable(Figure2).
G024336
1
2
5
3
4
Figure2
1.3-pinor9-pinconnector4.9-pinconnector
2.Thumbscrew
5.USBConnector
3.9-socketconnector
3.Securetheadapter-harnessconnectortothe
diagnostic-cableconnectorwiththe2thumbscrewson
theadapterconnector(Figure2).
4.Atthemachine,removethedustcapfromthe
diagnostic-portconnectorforthemachine(Figure3,
Figure4,orFigure5).
G024338
1
Figure3
1.Dustcap(RTproductsrightside)
2
G024350
1
Figure4
1.Dustcap(DD4045rearbatterycompartment)
Figure5
1.Dustcap(directional-drillsexcepttheDD4045underthe
enginehood)
5.Connecttheadapterharnesstothediagnostic-port
connectorforthemachineasfollows:
Foramachinewitha3-socketdiagnostic-port
connector,connectitasfollows:
A.Alignthetabontheadapter-harnessplugto
thelatchofthediagnosticport(
Figure6).
Figure6
1.Latch
4.Connector(3-pinadapter
cable)
2.Diagnostic-portconnector
5.Connector(diagnostic
cable)
3.Adapter-harnessplug(3
pin)
B.Firmlyinserttheplugintotheportuntilthe
latchofthediagnostic-portconnectorlocks
(
Figure6).
Foramachinewitha9-socketdiagnostic-port
connector,connectitasfollows:
A.Alignthepinnotchonthediagnostic-port
tothepinnotchontheadapter-harnessplug
(Figure7).
G024357
1 2
3
4
Figure7
1.Pinnotch(diagnostic-port)
3.Adapter-harnessplug
(9-pin)
2.Diagnostic-portconnector
(9-socket)
4.Socketnotch
(adapter-harnessplug)
B.Firmlyinserttheplugintotheport(Figure7).
6.InserttheUSBconnectorofthediagnosticcableinto
theUSBportonthecomputer.
Note:Whenthediagnosticcableispluggedinto
thecomputerandthecomputerisrunning,thePWR
3
indicatorlightonthehousingofthediagnosticcable
illuminates(Figure8).
Note:Whentheadaptercableisconnectedtothe
diagnosticportofthemachineandthediagnosticcable,
andthecontrolsystemofthemachineisenergized,the
CANindicatorlightonthehousingofthediagnostic
cablewillilluminate(Figure8).
CAN
PWR
G024335
1
2
Figure8
1.PWRindicatorlight
2.CANindicatorlight
7.Turnthemasterandignitionkeyswitchtotheon
position.
Note:Turnthemasterswitchandignitionkeyswitch
offpriortodisconnectingthediagnosticcablefrom
theport.
RunningtheDiagnostic
Software
ContactaToroTechnicalServicerepresentativefor
instructionsonhowtousethediagnosticsoftwareonyour
machine.
4
/