Installation
Note:UsethiskitasadataconnectionbetweentheECU(electroniccontrolunit)onyourmachineandthecomputerthat
youwillusetoanalyzethecomponentfunctionsofthemachine.Inadditiontothiskit,youwillneed2softwareapplications
installedonyourcomputer:ThePlus+1GuideServiceToolcreatedbySauerDanfossandthesystemdiagnosticsoftware
createdbyTheToro®Company.
PreparingyourComputer
DownloadingthePlus+1GuideService
ToolSoftware
1.Onyourcomputer,navigatetotheToroCompany
PortalforPlus+1GUIDEServiceToolSoftware&
Licensetodownload.
2.NavigatetoGatewayPartsandServiceCenter.
3.ClicktheServiceLibrarytab.
4.ScrolltotheUndergroundEquipmenttab.
5.ClicktheDiagnosticSoftwarelink.
6.ClickthePlus+1GUIDEServiceToolSoftware&
Licenselinktodownloadit.
7.Whenthedownloadiscomplete,thePlus+1iconwill
appearonyourdesktop.
8.Onyourcomputer,navigatetotheToroCompany
PortalforthecorrectDiagnosticle.
9.NavigatetoGatewayPartsandServiceCenter.
10.ClicktheServiceLibrarytab.
11.ScrolltotheUndergroundEquipmenttab.
12.ClicktheDiagnosticSoftwarelink.
13.Clicktheproducttype.
14.Clickthemodelnumbertoobtainthecorrect
diagnosticle.
15.Savethediagnosticletoyourdesktop.
©2014—TheToro®Company
8111LyndaleAvenueSouth
Bloomington,MN55420
Registeratwww.Toro.com.
OriginalInstructions(EN)
PrintedintheUSA
AllRightsReserved
*3379-504*B
InstallingtheToroSystemDiagnostic
Software
Thisproceduredescribeshowtoinstallingthesystem
diagnosticsoftwarefromtheGatewayPartsandService
CenterwebsitefortheToroCompany.
1.GototheGatewayPartsandServiceCenter.
2.OpenthePlus+1GUIDEServiceTool.
3.Clickonthediagnosticicononthetoptoolbar.
4.ThediagnosticprogramwillloadinPlus+1GUIDE
ServiceTool.
5.Refertoform2000–4002ToroPlus+1Diagnostic
SoftwareInstructionalManualforfurtherinformation.
InstallingtheAdapterHarness
andDiagnosticCable
1.Selecttheharnessadapter(Figure1)foryourmachine
byusingthetablebelow .
AdapterTable
ProducttypeProductNameAdapterHarness
Type
DirectionaldrillDD12153-pinconnector
DD14163-pinconnector
DD20243-pinconnector
DD32383-pinconnector
DD40459-pinconnector
RideonTrencherRT9609-pinconnector
RT10009-pinconnector
RT11609-pinconnector
RT12009-pinconnector
G024334
1
2
3
4
5
6
3
4
Figure1
1.3-pinconnector
4.9-socketconnector(end
view)
2.3-pinconnector(endview)
5.9-pinconnector
3.9-socketconnector
6.9-pinconnector(endview)
2.Connectthe9-socketconnectortothe9-pinconnector
ofthediagnosticcable(Figure2).
G024336
1
2
5
3
4
Figure2
1.3-pinor9-pinconnector4.9-pinconnector
2.Thumbscrew
5.USBConnector
3.9-socketconnector
3.Securetheadapter-harnessconnectortothe
diagnostic-cableconnectorwiththe2thumbscrewson
theadapterconnector(Figure2).
4.Atthemachine,removethedustcapfromthe
diagnostic-portconnectorforthemachine(Figure3,
Figure4,orFigure5).
G024338
1
Figure3
1.Dustcap(RTproductsrightside)
2
G024350
1
Figure4
1.Dustcap(DD4045rearbatterycompartment)
Figure5
1.Dustcap(directional-drillsexcepttheDD4045underthe
enginehood)
5.Connecttheadapterharnesstothediagnostic-port
connectorforthemachineasfollows:
Foramachinewitha3-socketdiagnostic-port
connector,connectitasfollows:
A.Alignthetabontheadapter-harnessplugto
thelatchofthediagnosticport(
Figure6).
Figure6
1.Latch
4.Connector(3-pinadapter
cable)
2.Diagnostic-portconnector
5.Connector(diagnostic
cable)
3.Adapter-harnessplug(3
pin)
B.Firmlyinserttheplugintotheportuntilthe
latchofthediagnostic-portconnectorlocks
(
Figure6).
Foramachinewitha9-socketdiagnostic-port
connector,connectitasfollows:
A.Alignthepinnotchonthediagnostic-port
tothepinnotchontheadapter-harnessplug
(Figure7).
G024357
1 2
3
4
Figure7
1.Pinnotch(diagnostic-port)
3.Adapter-harnessplug
(9-pin)
2.Diagnostic-portconnector
(9-socket)
4.Socketnotch
(adapter-harnessplug)
B.Firmlyinserttheplugintotheport(Figure7).
6.InserttheUSBconnectorofthediagnosticcableinto
theUSBportonthecomputer.
Note:Whenthediagnosticcableispluggedinto
thecomputerandthecomputerisrunning,thePWR
3
indicatorlightonthehousingofthediagnosticcable
illuminates(Figure8).
Note:Whentheadaptercableisconnectedtothe
diagnosticportofthemachineandthediagnosticcable,
andthecontrolsystemofthemachineisenergized,the
CANindicatorlightonthehousingofthediagnostic
cablewillilluminate(Figure8).
CAN
PWR
G024335
1
2
Figure8
1.PWRindicatorlight
2.CANindicatorlight
7.Turnthemasterandignitionkeyswitchtotheon
position.
Note:Turnthemasterswitchandignitionkeyswitch
offpriortodisconnectingthediagnosticcablefrom
theport.
RunningtheDiagnostic
Software
ContactaToroTechnicalServicerepresentativefor
instructionsonhowtousethediagnosticsoftwareonyour
machine.
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Toro Diagnostic Cable Kit, DD Series Directional Drill or RT Series Traction Unit Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI