FIELD CONTROLS B-34 Draft Regulator Installation guide

Type
Installation guide

FIELD CONTROLS B-34 Draft Regulator: Improve Heating Efficiency and Safety in Your Home

The FIELD CONTROLS B-34 Draft Regulator is a high-precision device designed to optimize chimney draft for improved fuel efficiency and enhanced safety in wood, coal, and oil-fired heating systems. With its accurate regulation capabilities, the B-34 ensures optimal combustion, reduces fuel consumption, and minimizes smoke backdraft, creating a safer and more efficient heating environment.

FIELD CONTROLS B-34 Draft Regulator: Improve Heating Efficiency and Safety in Your Home

The FIELD CONTROLS B-34 Draft Regulator is a high-precision device designed to optimize chimney draft for improved fuel efficiency and enhanced safety in wood, coal, and oil-fired heating systems. With its accurate regulation capabilities, the B-34 ensures optimal combustion, reduces fuel consumption, and minimizes smoke backdraft, creating a safer and more efficient heating environment.

www.eldcontrols.com
Please retain these instructions after installation.
This device MUST be installed by a qualied agency in accordance with the manufacturer's installation instructions. The denition of
a qualied agency is: any individual, rm, corporation or company which either in person or through a representative is engaged
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the
precautions required, and has complied with all the requirements of the authority having jurisdiction.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
Installation Date:
Installed By: Phone:
BAROMETRIC
DRAFT CONTROL
Model: B34
LISTED UNDER RE-EXAMINATION SERVICE OF UNDERWRITERS LABORATORIES, INC. LISTED UNDER LABEL SERVICE
OF CANADIAN STANDARDS ASSOCIATION. NOT CSA CERTIFIED FOR SOLID FUELS
The regulator contained in this package is manufactured with careful precision. It is designed to regulate
chimney draft with a high degree of accuracy and fuel eciency.
ITEMS INCLUDED:
1- Draft Control Counterbalance
1- Weight Assembly
1- Hex Nut
1- Knurled Nut
page 2
BALANCING WEIGHT ASSEMBLY AND
DRAFT ADJUSTMENT FOR WOOD AND
COAL FIRED APPLICATIONS
1. Assemble the counterbalance weight
assembly to the draft control as shown
in Figure 1. Thread counterbalance
weight through threaded nut attached to
the gate. Assemble hex nut and knurled
nut on front of gate as shown in
Figure 1.
2. Installation of this Draft Control should
be made in accordance with the stove
manufacturer’s instructions. When this
is not possible, follow the directions
below. (NOTE: For the regulator to operate properly, the
chimney must be clean and free of obstructions.)
3. The best setting for wood and coal burners is a draft
gauge reading of .04” to .08” W.C. If a draft gauge is
not available, with the draft regulator fully installed and
a good re burning, adjust the counterbalance weight
closer to the gate for as low a draft setting as possible,
without the re dying or getting smoke-back with the
stove door slightly open. To obtain higher heat levels,
move the weight away from the gate to increase
the setting.
4. Turn knurled nut counterclockwise for less draft, clockwise
for more draft.
5. When adjustment is made for desired draft, lock the
counterbalance weight assembly in place by tightening
the hex nut located under the knurled nut against
the gate.
6. For best combustion eciency, stack temperature (below the draft regulator) should be 350°F to 45F
for dry wood. Recommended stack temperatures and draft settings for coal vary according to the
manufacturer of the stove.
WEIGHT ASSEMBLY
Attach weight assembly to damper prior to its installation in
ue pipe. (See Figure 1)
LOCATION OF DRAFT CONTROL BEST LOCATIONS FOR
SOLID FUELS
Determine the best locations to mount the draft regulator
using Figures 2-7.
MOUNTING CONSIDERATIONS
Damper must be mounted with the hinge pins horizontal
and the face of the damper plumb for correct operation.
This is done by rotating the damper section within the collar
for any pipe position. Tighten screw to hold rmly in place.
(See Figure 8)
Figure 1
*Selected sizes CSA and UL approved.
Not CSA certied for solid fuels.
Figures 2-7
Figure 8
page 3
FOR OIL FIRED APPLICATIONS
1. Assemble the counterbalance weight assembly to the draft control as shown in Figure 1. Thread
counterbalance weight through threaded nut attached to the gate. Assemble hex nut and knurled nut on
front of gate as shown in Figure 1.
2. Proper operation of the regulator depends upon proper installation and adjustment. Use a CO
2
indicator,
stack thermometer and draft gauge to adjust draft for oil red burners. Domestic oil burners work best
with the draft over re of .01" to .02" W.C.
3. Turn knurled nut counterclockwise for less draft, clockwise for more draft.
4. When adjustment is made for desired draft, lock the counterbalance weight assembly in place by
tightening the hex nut located under the knurled nut against the gate.
Phone: 252.522.3031 Fax: 252.522.0214
www.fieldcontrols.com
© Field Controls, LLC P/N 46068600 Rev D 04/15
WARRANTY
For warranty about this or any Field Controls product, visit:
www.eldcontrols.com/warranty
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

FIELD CONTROLS B-34 Draft Regulator Installation guide

Type
Installation guide

FIELD CONTROLS B-34 Draft Regulator: Improve Heating Efficiency and Safety in Your Home

The FIELD CONTROLS B-34 Draft Regulator is a high-precision device designed to optimize chimney draft for improved fuel efficiency and enhanced safety in wood, coal, and oil-fired heating systems. With its accurate regulation capabilities, the B-34 ensures optimal combustion, reduces fuel consumption, and minimizes smoke backdraft, creating a safer and more efficient heating environment.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI