Mammoth Q6SE, Three Phase Product information

Type
Product information
208/230 VoltConvertible Packaged Heat Pump Three Phase 60Hz
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150V to ground.
4. If any of the original wire as supplied with the furnace
must be replaced, it must be replaced with wiring
material having a temperature rating of at least 105°C.
5. For supply wire ampcities overcurrent protection, see
unit rating plate.
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
3. Ne convient pas aux installations de plus de 150 V
a la terre.
04/20
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
NOTE: See Installation
Instructions for wiring,
application, and
Information concerning
accessory Heat Kits and
other options.
WIRING DIAGRAM
DEFROST BOARD OPERATION:
1. Heat Pump operates in heating mode until the combination of outdoor ambient and outdoor coil temperatures initiate
a defrost cycle. The outdoor coil temperature must be at or below 32°F before the defrost cycle begins.
2. There must be a minimum of 20 minutes between defrost cycles. After this time, temperature conditions must call for
defrost continuously for 4 1/2 minutes before a defrost cycle is initiated.
3. The defrost cycle ends when the outdoor temperature reaches 32°F or the defrost terminate time of 13 minutes 39
seconds is reached.
1016071A
(Replaces 10160710)
1
2
3
4
5
6
7
8
9
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
T2
T1
T3
R
C
S
T2
T1
N
G
L
C
T3
T4
T5
TO 208/230 VAC
POWER SUPPLY
9
8
1
7
6
5
4
3
2
9
8
1
7
6
5
4
3
2
3 PHASE
COMPRESSOR
CAPACITOR
HEATER
PLUG
OUTDOOR
FAN MOTOR
ECONOMIZER
PLUG
ECONOMIZER
PLUG
TO DISCHARGE
AIR SENSOR
3 AMP
FUSE
BLOWER RELAY
BLOWER
MOTOR
TRANSFORMER
CCH
L1
L2
L3
T1T2T3
24V
240V
208V
COM
NC
NO C
ORANGE
BLUE
G
C
A1
W1
R
Y2
O Y1
W2
E
DEFROST
SENSOR
YE
YE
YE
AMBIENT
SENSOR
M
PRESS
SW
REV
VALVE
AMBIENT
AMBG
COILG
COIL
L
DEMAND
DEFROST
BOARD
R CYO
W2-IN
W2-OUT
COND FAN
BLACK
BLACK
REVERSING
VALVE SOLENOID
HIGH
PRESSURE
SWITCH
LOW
PRESSURE
SWITCH
(SELECT MODELS)
BLACK
BLACK
BLACK
BLACK
YELLOW
YELLOW
RED
RED
RED
RED
RED
RED
RED
YELLOW
BLUE
BLUE
WHITE
WHITE
BLACK
BLACK
BLACK
BROWN
ORANGE
YELLOW
YELLOW
YELLOW
YELLOW
GREY
GREY
GREY
GREEN
GREEN
GREEN
ORANGE
BROWN
ORANGE
YELLOW
BLACK
BLACK
BLACK
BLACK
RED
WHITE
WHITE
BLACK
BLACK
YELLOW
YELLOW
ORANGE
BLACK
WHITE
BLUE
WHITE
RED
BLACK
YELLOW
  • Page 1 1