Leviton R51-12650-00I, 12650-W Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Leviton R51-12650-00I Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What safety precautions should be taken before installing the CO/ALR outlet?
    What electrical codes and regulations should be followed during installation?
    Can this device be used with different types of wire?
    What is the purpose of the break-off fin located between the two brass terminal screws?
    How do I remove the break-off fin?
    What is the recommended amount of wire insulation to remove before connecting the wires?
    How should the wires be connected to the terminal screws?
    What is the maximum wire size that the terminal screws can accommodate?
    What is the final step in the installation process?
CO/ALR Outlet
Contacto CO/ALR
Contact Leviton Technical Support at 800-824-3005 (USA ONLY) or visit www.leviton.com for warranty information.
Para obtener información de garantía llame a Soporte Técnico de Leviton al 800-824-3005 (SOLO EE.UU) o visite www.leviton.com.
© 2017 Leviton Mfg. Co., Inc.
CR-C22-12650-10E-W
WARNINGS AND CAUTIONS:
TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING.
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
NOTE: THIS DEVICE MAY BE USED WITH COPPER, COPPER-CLAD, OR ALUMINUM WIRE.
TO INSTALL:
FOR SEPARATE FEED CONVERSION ONLY: OUR OUTLET IS PROVIDED WITH A BREAK-OFF FIN LOCATED BETWEEN THE TWO BRASS TERMINAL SCREWS.
1) IF YOU WANT TO HAVE THE TOP OUTLET AND THE BOTTOM OUTLET CONTROLLED BY TWO DIFFERENT HOT WIRES (TWO CIRCUITS), REMOVE THE BREAK-
OFF FIN BEFORE WIRING.
2) WITH NEEDLENOSE PLIERS, BEND FIN BACK AND FORTH UNTIL IT BREAKS OFF.
3) REMOVE WIRE INSULATION ABOUT 5/8” (1.6CM.).
4) CONNECT WIRES PER WIRING DIAGRAM: LOOP WIRES CLOCKWISE 3/4 TURN AROUND TERMINAL SCREWS.
5) TIGHTEN ALL SCREWS FIRMLY OVER WIRE LOOPS. TERMINAL SCREWS ACCEPT UP TO #10 AWG COPPER, COPPER CLAD OR ALUMINUM WIRE.
6) MOUNT DEVICE AND WALLPLATE.
7) RESTORE POWER.
INSTALLATION IS COMPLETE.
PARA INSTALAR:
SOLO PARA ALIMENTACION SEPARADA: ESTE CONTACTO TIENE UNA ALETA ROMPIBLE UBICADA ENTRE LAS DOS TERMINALES DE LATÓN.
1) SI QUIERE QUE EL CONTACTO DE ARRIBA Y EL CONTACTO DE ABAJO SE CONTROLEN CON 2 ALAMBRES FASE DIFERENTES (DOS CIRCUITOS), ROMPA
LA ALETA ANTES DE LA INSTALACIÓN.
2) CON UN ALICATE DE PUNTA, DOBLE HACIA ATRÁS Y ADELANTE HASTA QUE SE ROMPA.
3) PELE 1.6 CM (5/8”) DE AISLANTE.
4) CONECTE LOS CABLES SEGÚN EL DIAGRAMA DE CABLEADO: ENROSQUE LOS ALAMBRES 3/4 DE VUELTA HACIA LA DERECHA ALREDEDOR DE LOS
TORNILLOS TERMINALES.
5) APRIETE LOS TORNILLOS SOBRE EL ALAMBRE ENROSCADO. LOS TORNILLOS TERMINALES ACEPTAN CABLE DE COBRE, REVESTIDO DE COBRE O DE
ALUMINIO HASTA #10 AWG.
6) MONTE EL PRODUCTO Y PLACA MURAL.
7) RESTABLEZCA LA CORRIENTE. LA INSTALACIÓN ESTÁ COMPLETA.
ADVERTENCIAS Y PRECAUCIONES:
PARA EVITAR DESCARGA ELÉCTRICA, FUEGO, O MUERTE, INTERRUMPA EL PASO DE ENERGÍA MEDIANTE EL INTERRUPTOR DE CIRCUITO O FUSIBLE.
¡ASEGÚRESE DE QUE EL CIRCUITO NO ESTÉ ENERGIZADO ANTES DE INICIAR LA INSTALACIÓN!
• PARA INSTALARSE Y/O USARSE DE ACUERDO CON LOS CÓDIGOS ELÉCTRICOS Y NORMAS APROPIADAS.
NOTA: ESTE PRODUCTO PUEDE SER USADO CON CABLE DE ALUMINIO, COBRE O REVESTIDO DE COBRE.
CO/ALR Outlet
Rated: 15A-125V
Contacto CO/ALR
Capacidad: 15A-125V
Neutral (White)
Neutro (Blanco)
Hot (Black)
Fase (Negro)
Green Grounding
Screw
Tornillo verde para
conexión a tierra
Break-off
Fin
Aleta
Rompible